VENTINg INSTALLATION 

INSTRUCTIONS

NOTICE:  Read  these  instruc

-

tions  completely  before  at-

tempting installation.

These models are tested and approved for use 

with FMI PRODUCTS, LLC (direct-vent) pipe 

components and terminations.

The venting system must terminate on the outside of 

the structure and can not be attached to a chimney 

or flue system serving a separate solid fuel or gas 

burning appliance. A direct-vent appliance must 

have its own venting system. DO NOT common 

vent this appliance.

These models are approved to be vented either 

horizontally through an outside wall or vertically 

through a roof or chase enclosure using the fol

-

lowing guidelines:

•  When venting system terminates horizontally 

on an outside wall, you may install a standoff 

if the termination cap is to be installed directly 

on a combustible finish such as vinyl, wood, 

stucco, etc.

•  Never  run  the  vent  downward  as  this  may 

cause  excessive  temperatures  which  could 

cause a fire.

•  Vent pipe air space clearances to combustibles 

are 1" on all sides except on the horizontal 

sections, which  requires  2" clearance  from 

the top of the pipe. Where the termination cap 

penetrates a combustible wall, 1" air space 

clearance is required.

•  Snorkel  terminations  are  required  when 

minimum clearance to grade cannot be met (see 

Figure 16 on page 11).

•  Have fireplace and selected vent components on 

hand to help determine the exact measurements 

when elbowing or offsetting. Always use wall 

firestops when penetrating walls and firestops 

when penetrating ceilings or attic spaces.

•  If using a venting configuration of only hori

-

zontal venting with no vertical run, a 1/4" rise 

for every 12" of run toward the termination is 

required.

•  For installation of fireplace at elevations of 4000 

feet or greater, pay special attention to venting 

requirement recommendations.

 WARNING: Read all instruc-

tions completely and thoroughly 

before  attempting  installation. 

Failure to do so could result in 

serious injury, property damage 

or loss of life. 

NOTICE: Failure to follow these in

-

structions will void the warranty. 

NOTICE: Do not seal termination 

cap to vent pipe. Cap must be 

removable  for  vent  inspection 

and maintenance.

INSTALLATION PRECAUTIONS

•  Wear gloves and safety glasses for protection

•  Use extreme caution when using ladders or 

when on roof tops

•  Be aware of electrical wiring locations in walls 

and ceilings

The following actions will void the warranty on 

your venting system:

•  Installation of any damaged venting component

•  Unauthorized modification of the venting sys

-

tem (Do not cut or alter vent components)

•  Installation of any component part not manufac

-

tured or approved by FMI PRODUCTS, LLC

•  Installation other than as instructed by these 

instructions

 WARNING: This gas fireplace 

and vent assembly must be vented 

directly to the outside. The venting 

system must NEVER be attached 

to a chimney serving a separate 

solid fuel burning appliance. Each 

direct-vent  gas  appliance  must 

use a separate vent system. Do not 

use common vent systems.

  WARNING:  Vent  pipe  air 

space clearances to combustibles 

are 1" on all sides except on the 

horizontal sections, which require 

2" clearances from the top of the 

pipe. Where the termination cap 

penetrates a combustible wall, 1" 

air space clearance is required.

Содержание DVC36B

Страница 1: ...ce agency or the gas supplier This appliance may be installed in an aftermarket per manently located manufactured mobile home where not prohibited by local codes Aftermarket Completion of sale not for purpose of resale from the manufacturer State of Massachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts INSTALLER Leave this manual with ...

Страница 2: ...vice or repair this fireplace Have fireplace inspected annu ally by a qualified service person Safety Information Table of Contents Safety Information 2 Local Codes 3 Product Identification 3 Product Features 3 Pre Installation Preparation 4 Location of Termination Cap 6 Venting Installation Instructions 7 Replacement Parts 16 Technical Service 17 Accessories 17 Illustrated Parts Breakdown and Par...

Страница 3: ...54 Available from American National Standards Institute Inc 1430 Broadway New York NY 10018 National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 Figure 1 Direct Vent Fireplace Glass Door Assembly Switch Bracket for Optional Remote and Blower Upper Louver Panel Lower Louver Panel Flue Collar Nailing Flange Product Features These are a few facts that can help you understand and...

Страница 4: ...f your fireplace is to be installed directly on carpeting vinyl tile or any combustible mate rial other than wood it must be installed on a metal or wood panel extending the full width and depth of the fireplace See Figure 3 Your fireplace is designed to be used in zero clearance installations Wall or framing material can be placed directly against any exterior sur face on the back sides or top of...

Страница 5: ...Nailing Tabs 36 Models 42 Models NOTICE This fireplace is in tended for use as supplemental heat Usethisfireplacealongwith yourprimaryheatingsystem Do not install this fireplace as your primaryheatsource Ifyouhavea central heating system you may run system s circulating blower while using fireplace This will help circulate the heat through out the house In the event of a power outage you can use t...

Страница 6: ...10 000 and 50 000 12 30 cm in Canada if between 10 000 and 100 000 12 30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L clearance above paved side walk or a paved driveway located on public property 84 213 3 cm minimum M clearance under ver...

Страница 7: ...tops when penetrating ceilings or attic spaces If using a venting configuration of only hori zontal venting with no vertical run a 1 4 rise for every 12 of run toward the termination is required For installation of fireplace at elevations of 4000 feet or greater pay special attention to venting requirement recommendations WARNING Read all instruc tionscompletelyandthoroughly before attempting inst...

Страница 8: ...sh pipe sec tions together and twist one section clockwise approximatelyone quarterturnuntilthesections arefullylocked seeFigure8 Note Horizontal runs of vent must be supported every three feet Use wall straps for this purpose 3 Use a 45 elbow to connect venting system to fireplace flue collar The elbow is designed to be twist locked onto the flue collar as described in step 2 IMPORTANT Do not att...

Страница 9: ...ch toexteriorwallwithwoodscrewsprovided see Figure 11 The siding standoff must sit flush against the exterior fascia material 7 Connecting Vent Cap with Horizintal Vent Pipe Slide the wall firestop over the vent pipe before connecting horizontal run to vent cap see Figure 12 8 Carefully move fireplace with vent assembly attached toward wall and insert vent pipe into horizontal termination The pipe...

Страница 10: ...ermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward as this may cause excessive temperatures which could cause a fire Operation of improperly installed and main tained venting system could result in serious injury property damage or loss of life GROUND FLOOR INSTALLATION Recommended Applications Installation using cabinet surrounds ...

Страница 11: ...2 min None 30 max 54 1 2 min 1 ft 48 max 66 1 2 min 2 ft 60 max 78 1 2 min 3 ft 84 max 90 1 2 min 4 ft 20 max Ground Floor Corner Venting Not to Exceed H Limits SNORKEL TERMINATION INSTALLATION Recommended Applications Installations requiring a vertical rise on building exterior Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are available for insta...

Страница 12: ...ion Configuration for Venting Using Two 90 Elbows 45 Elbow HORIZONTAL SYSTEM INSTALLATION USING TWO 90 ELBOWS The following configurations show the minimum vertical rise requirements for a horizontal system using two 90 elbows Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max 20 max 20 max Figure 18 Horizontal Termination Configura...

Страница 13: ...f the area above the ceiling is an insulated ceiling or an attic space nail firestop from the top side This prevents loose insulation from falling into the required clearance space If the area above the ceiling is a living space install firestop below theframedhole Thefirestopshouldbeinstalled with no less than three nails per side see Figure 20 2 Assemble the desired lengths of pipe and elbows ne...

Страница 14: ... first floor including storage spaces and closets you must enclose pipe You may frame and sheetrock the enclosure with standard construction material Make sure and meet the minimum allowable clearances to combustibles Do not fill any of the required air spaces with insulation Venting Installation instructions Continued Vertical Termination Configurations Figures 21 through 24 show four different c...

Страница 15: ... 6 max 6 min 12 max 7 min 18 max 8 min 20 max Note Vertical V1 Vertical V2 40 max Figure 23 Vertical Venting Configuration Using Two 90 Elbows Vertical Round High Wind Termination Shown 45 Elbow Vertical Venting V 40 max Figure 24 Vertical Venting Configuration With No Horizontal Run Vertical Round High Wind Termination Shown Note Install restrictor into inner collar of fireplace as shown 45 Elbow...

Страница 16: ...HTK 58 High Wind Round Horizontal Termination Kit Includes Round Termination Venting Installation instructions Continued Wall Firestop 45 Elbow Number Description HHT 58 High Wind Round Horizontal Termination Kit Galvanized HTS 58 Horizontal Square Termination Galvanized HTKS 58 Horizontal Square Termination Kit Includes Square Termination Wall Firestop 45 Elbow VT 58 Vertical Round Termination Ga...

Страница 17: ...PRODUCTS LLC at 1 866 328 4537 for referral information When calling have ready model number of your fireplace the replacement part number Technical Service You may have further questions about installation operation or troubleshooting If so contact FMI PRODUCTS LLC s Customer Service Depart ment at 1 866 328 4537 When calling please have your model and serial numbers of your heater ready Youcanal...

Страница 18: ...www fmiproducts com 118197 01D 18 Illustrated Parts Breakdown Models V DVC36 B H and V DVC42 B H 6 7 10 17 18 13 2 12 19 8 1 4 11 9 14 3 16 5 15 ...

Страница 19: ... 02 Right Refractory Brick Panel 1 111301 02 Right Refractory Brick Panel 1 110990 01 Right Refractory Brick Panel 1 111216 01 Right Refractory Brick Panel 1 111298 01 Right Refractory Brick Panel 1 111301 01 Right Refractory Brick Panel 1 KEY NO V DVC36 B H V DVC42 B H DESCRIPTION QTY 1 Firebox Assembly 1 2 Face Weldment 1 3 108010 01 108328 01 Door Assembly 1 108328 02 Door Assembly V Models Onl...

Страница 20: ...or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material laborandincidentalcostsassociatedwithwarrantyrepairs unlessexpressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded from this warranty are ...

Отзывы: