REPLACING TRANSFORMER

1.  Follow steps 1 through 3 under 

Replacing 

Heater/Blower, 

page 9.

2.  Disconnect transformer wires from control 

board.

3.  Remove screws from outside of firebox 

surround  to  remove  transformer  (see 

Figure 14).

4.  Remove and discard transformer.
5.  Place  new  transformer  against  inside 

of firebox surround and replace screws 

removed in step 3.

6.  Reconnect  transformer  wires  to  control 

board (see 

Wiring Diagram,

 page 12).

7.  Replace top panel and screws.
8.  Replace trim

Figure 14 - Removing Transformer

Transformer Screws

5.  Reconnect  wires  to  main  control  board 

(see 

Wiring Diagram,

 page 12).

6.  Replace top panel and screws.
7.  Replace trim

Figure 16 - Replacing Settings Control 

Board

Screws

Settings 

Control Board

REPLACING MAIN CONTROL BOARD

1.  Follow steps 1 through 3 under 

Replacing 

Heater/Blower, 

page 9.

2.  Disconnect wires to main control board.
3.  Squeeze top of standoffs to remove main 

control board and discard.

4.  Gently  push  new  control  board  onto 

standoffs to install.

Figure 15 - Control Board

Main Control 

Board

Standoffs

Transformer

Figure 13 - Removing Heater from 

Blower

Heater

Blower

CLEANING AND MAINTENANCE

Continued

REPLACING SETTINGS CONTROL 

BOARD

1.  Follow steps 1 through 3 under 

Replacing 

Heater/Blower, 

page 9.

2.  Disconnect  wires  from  main  control 

board.

3.  Remove screws from bracket to remove 

settings control board.

4.  Place new settings control board into posi-

tion making sure each control is aligned 

with  slot  in  panel.  Install  using  screws 

from  step  3.  DO  NOT  overtighten. This 

will damage control board.

5.  Reconnect  wires  to  main  control  board 

(see 

Wiring Diagram,

 page 12).

6.  Replace top panel and screws.
7.  Replace trim

Содержание CGEF23B

Страница 1: ...ere gasoline paint or flammable liquids are or are stored This fireplace meets the construction and safety stan dards of H U D for application in manufactured homes when installed according to these instructions INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference For more information visit www fmiproducts com ELECTRIC FIREPLACE INSERT MODELS CGEF23B AND ...

Страница 2: ...Extreme caution is necessary when any heater is used by or near children or inva lids and whenever heater is left operating and unattended 5 Always unplug heater when not in use 6 Do not operate any heater with a damaged cord or plug or if heater malfunctions or has been dropped or damaged in any way Return heater to authorized service facility for examination electrical or mechanical adjustment o...

Страница 3: ... wired and grounded in accordance with local codes or in theabsenceoflocalcodes withNationalElectric Code ANSI NFPA 70 latest edition or the Cana dian Electric Code CSA C22 1 as appropriate 19 17 8 23 18 Always disconnect power before perform ing any cleaning maintenance or reloca tion of heater 19 To prevent a possible fire do not burn wood or other materials in this heater 20 To prevent electric...

Страница 4: ...he unit if it is damaged or has malfunctioned Ifyoususpectthe unit is damaged return the unit to an authorized service facility forexamination electricalorme chanical adjustment or repair WARNING Due to high tem peratures this heater should be located out of traffic Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 feet 0 9 m from the front of the ...

Страница 5: ... these instructions is not fol lowed exactly a fire or explosion mayresultcausingpropertydam age personal injury or death Do not store or use gasoline or other flammable vapors in the vi cinity of this or any other heater Installing fireplace Select a suitable location that is not suscep tible to moisture and is a safe distance from drapes furniture and high traffic areas Note Follow all national ...

Страница 6: ... location at least 3 feet 0 9 m away from combustible materials such as curtains or drapes furniture bedding paper etc 2 Mark desired location on floor and store unit in a safe dry and dust free location 3 Frame in an opening leaving at least 1 4 6 mm around the edge of the unit see Any new wiring must be done in compliance with local and national codes and other ap plicable regulations in order t...

Страница 7: ...ustible or non combustible finishing materials When using paint or lacquer to finish the mantel they must be heat resistant to prevent discoloration Operation The controls see Figure 5 are located behind hinged control panel door If using heater con trol panel door will be hot during and immedi ately after operation Open door by pressing on right side A spring magnet will push door forward Pull do...

Страница 8: ...ing or servicing Cleaning Firebox 1 Open control panel door by pressing on right side A spring magnet will push door forward Pull door down to open 2 Remove 2 screws holding front trim in place Pull gently to remove trim see Figure 8 There are magnets on the lower portion of trim see Figure 8 3 With gloves and safety glasses in place remove 4 screws from glass retainer brackets 2 per bracket 4 Car...

Страница 9: ...teps 1 and 2 of Cleaning Firebox page 8 2 Remove screws from around top panel of firebox see Figure 11 3 There are several wires attached to the top panel Carefully lift top panel 4 Disconnect heater blower wires from main circuit board 5 Remove screws holding heater blower to top panel see Figure 11 6 Remove brackets from heater blower see Figure 12 Save brackets and screws 7 To remove heater fro...

Страница 10: ...Control Board Replacing Main Control Board 1 Follow steps 1 through 3 under Replacing Heater Blower page 9 2 Disconnect wires to main control board 3 Squeeze top of standoffs to remove main control board and discard 4 Gently push new control board onto standoffs to install Figure 15 Control Board Main Control Board Standoffs Transformer Figure 13 Removing Heater from Blower Heater Blower Cleaning ...

Страница 11: ...een Glass 1 The glass is cleaned in the factory during assembly During shipment installation handling etc glass surface may collect dust particles These can be removed by buffing lightly with a clean damp cloth water only Glass should be completely dried with a lint free cloth or paper towel 2 In the event of glass breakage vacuum all remaining glass pieces with a shop vac DO NOTVACUUM WHILE PIECE...

Страница 12: ...arranty coverage for parts replaced under warranty Contact authorized dealers of this product If they can t supply original replacement part s call FMI PRODUCTS LLC at 1 866 328 4537 When calling have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory Accessories Purchase these a...

Страница 13: ...set switch by turning main power switch off and waiting 5 minutes then turning it back on or reset circuit breaker 1 Inspect wiring for loose connections 2 Call a qualified service techni cian to replace flame motor 1 Disconnect from power source and inspect wiring for loose connections and repair or replace if necessary 1 Disconnect from power source and inspect wiring for loose connections and r...

Страница 14: ...www fmiproducts com 120926 26C 14 13 18 19 8 12 9 21 16 5 1 17 4 2 11 10 15 7 14 6 3 20 Parts Models CGEF23B and VEF21B ...

Страница 15: ...netic Catch 1 6 120926 09 Main Control Board and Standoffs 5 1 7 120927 10 Transformer 1 8 120927 11 Heater 1 9 120926 12 Settings Control Board 1 10 120926 13 LED Drum Assembly 1 11 120927 14 Motor Drum 1 12 120926 15 LED Ember Strip 1 13 120926 20 Remote Control 1 14 120927 21 Remote Control Sensor 1 15 120927 22 Power Cord 1 16 120927 24 ON OFF Switch 1 17 120926 03 Front Glass 1 18 120926 02 C...

Страница 16: ...is product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs associated with warranty repairs unless expressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded ...

Отзывы: