background image

www.fmiproducts.com

116646-01J

21

Figure 32 - Gas Connection

Equipment Shutoff Valve with 
1/8" NPT Tap*

3" Minimum

Approved 
Flexible Gas 
Line

Cap  Pipe Nipple  Tee Joint

Sediment Trap/Drip Leg

Natural

 - From 

Gas Meter (5.5" 
W.C. to 10.5" 
W.C. Pressure)

Propane/LP

 

From External 
Regulator (11" 
W.C. to 14" 
W.C. Pressure)

* The equipment shutoff valve may be sup

-

plied with the appliance or you can purchase 
it from your retailer. 

We  recommend  that  you  install  a  sediment 
trap/drip leg in supply line as shown in Figure 
32. Locate sediment trap/drip leg where it is 
within reach for cleaning. Install in piping sys

-

tem between fuel supply and fireplace. Locate 
sediment trap/drip leg where trapped matter 
is not likely to freeze. A sediment trap traps 
moisture and contaminants. This keeps them 
from going into fireplace gas controls. If sedi

-

ment trap/drip leg is not installed or is installed 
wrong, fireplace may not run properly.

FIREplaCE INSTallaTION

Continued

Figure 33 - Connecting Flexible Gas Line 

to Millivolt Valve

CHECKING GAS CONNECTIONS

 WARNING: Test all gas piping 

and  connections,  internal  and 

external to unit, for leaks after 

installing or servicing. Correct 

all leaks at once.

 WARNING: Never use an open 

flame to check for a leak. Apply 

noncorrosive leak detection fluid 

to all joints. Bubbles forming show 

a leak. Correct all leaks at once.

pRESSURE TESTING GAS SUppLY 
pIpING SYSTEM 

Test Pressures In Excess Of 1/2 PSIG 
(3.5 kPa)

1.  Disconnect fireplace and its individual equip

-

ment shutoff valve from gas supply piping 
system. Pressures in excess of 1/2 psig (3.5 
kPa) will damage fireplace gas regulator.

2.  Cap off open end of gas pipe where equip

-

ment shutoff valve was connected.

3.  Pressurize  supply  piping  system  by  either 

opening  propane/LP  supply  tank  valve  for 
propane/LP gas fireplace or opening main gas 
valve located on or near gas meter for natural 
gas fireplace or using compressed air.

4.  Check all joints of gas supply piping sys

-

tem. Apply  noncorrosive  leak  detection 
fluid to all joints. Bubbles forming show a 
leak. Correct all leaks at once.

5.  Reconnect  fireplace  and  equipment 

shutoff valve to gas supply. Check recon

-

nected fittings for leaks. 

Flexible Gas Line
Do NOT Kink

Equipment 
Shutoff 
Valve

To Gas Supply 
(Natural)

To External 
Regulator 
(Propane/LP)

Control Valve

CONNECTING FIREpLACE TO GAS 
SUppLY

Installation Items Needed

•  5/16" hex socket wrench or nut-driver
•  sealant (resistant to propane/LP gas, not 

provided)

1.  Open lower louver door panel by gently 

pulling forward.

2.  Route  flexible  gas  line  (provided  by  in

-

staller)  from  equipment  shutoff  valve  to 
fireplace.  Route  flexible  gas  supply  line 
through one of the access holes on side 
of fireplace.

3.  Attach flexible gas line from gas supply to 

control valve (see Figure 33).

4.  Check all gas connections for leaks. See 

Checking Gas Connections

.

Содержание CGDV32NR

Страница 1: ...e or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installa...

Страница 2: ...produc tive harm IMPORTANT Read this owner s manualcarefullyandcompletely before trying to assemble op erate or service this fireplace Improper use of this fireplace cancauseseriousinjuryordeath from burns fire explosions electrical shock and carbon monoxide poisoning DANGER Carbonmonoxide poisoning may lead to death This fireplace must be installed by a qualified certified or licensed service per...

Страница 3: ...d Keep the appliance area clear and free from combustible ma terials gasoline and other flam mable vapors and liquids Do not place clothing or other flammable material on or near fireplace Never place any ob jects on fireplace 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used...

Страница 4: ...merican National Standards Institute Inc 1430 Broadway New York NY 10018 National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 Product Features These are a few facts that can help you under stand and enjoy your direct vent fireplace The venting system may be routed to the outside of your home in several ways It may vent through the roof vertical or it may vent to an outside ex...

Страница 5: ... can be placed directly against wall or framing material See framing details on page 6 If you plan on installing a television or enter tainment center recessed above your fire place it is recommended that you maintain a minimum 18 above top of louver opening When locating termination cap it is impor tant to observe the minimum clearances shown in Figure 7 page 7 If recessing into a wall you can av...

Страница 6: ...ion All minimum clearances must be met For available accessories for this fireplace see Accessories on page 37 If you are using a separate combustible mantel piece refer to Figure 6 for proper installation height You can install noncombustible mantels at any height above the fireplace Note Noncombustible mantels may discolor 323 8 345 8 17 Horiz Vent 20 Vert Vent Figure 5 Framing Clearances for Co...

Страница 7: ...10 000 and 50 000 12 30 cm in Canada if between 10 000 and 100 000 12 30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L clearance above paved side walk or a paved driveway located on public property 84 213 3 cm minimum M clearance under ver...

Страница 8: ... models are tested and approved for use with FMI PRODUCTS LLC direct vent pipe components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue system serving a separate solid fuel or gas burning appliance A direct vent appliance must have its own venting system DO NOT common vent this appliance These models are approved to...

Страница 9: ...t pipes Push pipe sections together and twist one section clockwise approximately one quarter turn until sections are fully locked see Figure 8 Note Horizontal runs of vent must be supported every three feet Use wall straps for this purpose 3 Use a 45 elbow to connect venting sys tem to fireplace flue collar The elbow is designed to be twist locked onto flue collar as described in step 2 IMPORTANT...

Страница 10: ...erior fascia material 7 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before connecting horizontal run to vent cap see Figure 12 Carefully move fireplace with vent as sembly attached toward wall and insert vent pipe into horizontal termination The pipe overlap should be a minimum of 1 1 4 see Figure 13 page 11 Venting Installation Continued Figure 10 Installing H...

Страница 11: ...e for every 12 of run toward termination is required NOTICE Donotsealtermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward as this may cause excessive temperatures which could cause a fire Operation of improperly installed and main tained venting system could result in serious injury property damage or loss of life Vertical V Horizon...

Страница 12: ...oor installation where pipe vents horizontally through wall over 12 horizontal pipe Basement installation where one foot clearance from ground to termination is possible SNORKEL TERMINATION INSTALLATION Recommended Applications Installations requiring a vertical rise on building exterior Any installation using snorkel termination to achieve one foot above ground Snorkel Termination 12 Min 12 Min A...

Страница 13: ...tion for Venting Using Two 90 Elbows Venting with Two 90 Elbows Horizontal H1 Vertical V Horizontal H1 Horizontal H2 5 min 2 max 6 max 6 min 4 max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20 max 8 max 20 max 45 Elbow Figure 18 Horizontal Termination Configuration for Venting Using Two 90 Elbows with Termination at 90 with Fireplace Venting with Two 90 Elbows Horizontal H1 Vertical V Horizontal...

Страница 14: ...ed clearance space If area above ceiling is a living space install firestop below framed hole Firestop should be installed with no less than 3 nails per side see Figure 20 2 Assemble desired lengths of pipe and elbows necessary to reach from fireplace flue up through firestop Be sure all pipe and elbow connections are fully twist locked see Figure 8 page 9 3 Cut a hole in roof using locating hole ...

Страница 15: ...ugh 24 show four different configurations for vertical termination Venting Installation Continued Figure 21 Vertical Venting Configuration Using Two 90 Elbows with Two Horizontal Runs Vertical Round High Wind Termination Shown Venting with Two 90 Elbows Horizontal H1 Vertical V Horizontal H2 5 min 2 max 6 min 4 max 7 min 6 max 8 min 8 max 20 max 8 max Note Install restrictor into inner collar of f...

Страница 16: ... see Figure 25 and a round horizontal termination be used Figure 25 Recommended 12 Extension for High Altitude Installation 45 Starter Elbow 12 Extension Parts list for venting kits and components FMI PRODUCTS LLC 5 8 Pipe Vent Kits Number Description P58 6 6 Section Double Wall Pipe Galvanized P58 12 12 Section Double Wall Pipe Galvanized P58 24 24 Section Double Wall Pipe Galvanized P58 36 36 Se...

Страница 17: ...with HTS 58 RF 58 Flat Roof Flashing PF58 927 Flex Pipe Section 9 to 24 PF58 1236 Flex Pipe Section 12 to 36 PF58 1854 Flex Pipe Section 18 to 54 VKF58 927 Flex Kit Includes Flex Pipe Wall Section 9 to 27 Firestop and Horizontal Square Termination CHECK GAS TYPE Use proper gas type for fireplace unit you are installing If your gas supply is not correct do not install fireplace See retailer where y...

Страница 18: ...n Wiring Diagram Decal 12 in Front of Blower Speed Control Control Shaft Locknut Control Knob Switch Bracket Blower Plug In Duplex Outlet Located underneath firebox floor against lower right outside wall Model BKT Installation Note When installing BKT thermostati cally controlled blower you must first secure thermal switch bracket to blower if it has not already been factory installed 1 Place gree...

Страница 19: ...ch Thermal Switch Bracket Power Cord Air Flow Direction Magnetic Strips Figure 30 Blower Wiring Diagram for Thermostat Controlled Models Blower Wiring Diagram CAUTION Label all wires prior to disconnection when servicingcontrols Wiringerrors can cause improper and dan gerous operation Verify proper operation after servicing Blue Variable Fan Switch Fan Switch N O Green White On 110 115 V A C Blowe...

Страница 20: ...to between 11 and 14 of water If you do not reduce incoming gas pressure Figure 31 External Regulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator with Vent Pointing Down fireplace regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 31 Pointing the vent down protects it from freezing rain or sleet CAUTION Use o...

Страница 21: ... a leak Correct all leaks at once PRessure Testing Gas Supply Piping System Test Pressures In Excess Of 1 2 PSIG 3 5 kPa 1 Disconnectfireplaceanditsindividualequip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig 3 5 kPa will damage fireplace gas regulator 2 Cap off open end of gas pipe where equip ment shutoff valve was connected 3 Pressurize supply piping system b...

Страница 22: ...ve to gas valve see Figure 35 or Figure 36 Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Light fireplace see Operation page 26 Check all other internal joints for leaks 6 Turn off fireplace see To Turn Off Gas to Appliance page 27 Installing optional wall Mount Switch gwmS2 1 Connect one terminal of 25 ft wire for wall switch to TPTH ...

Страница 23: ... remote control unit see Figure 40 2 Attach terminal wires to battery Place battery into battery housing 3 Replace battery cover onto remote control unit Figure 40 Installing Battery in Hand Held Remote Control Unit 9 Volt Battery Battery Housing Battery Cover Terminal Wires Remote Control Unit Removing Replacing Glass Door CAUTION Do not operate thisfireplacewithabrokenglass door panel or without...

Страница 24: ...ntinued Figure 42 Removing Replacing Glass Door Lock Unlock Glass Frame Assembly Screw Hinge Latch Installing Optional Brick liner Model BL32D WARNING If fireplace has been running turn off and un plug fireplace Let cool before installing brick liner This brick liner kit is optional You may pur chase brick liner from your local retailer or see page 37 CAUTION Always handle brick panels with two ha...

Страница 25: ...ly as instructed Do not modify logs Only use logs supplied with fireplace Open louvers remove screen unlock door latches and open glass door See steps 1 and 2 of Removing Glass Door page 24 Install logs according to instructions for fireplace model numbers 1 Place log 1 rear log on top of grate Make sure notches in bottom of log fit over grate see Figure 45 2 Rest log 2 large front log on pins on ...

Страница 26: ... YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not fol low these instructions exactly a fire or explosion may result causing property damage per sonal injury or loss of life A This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the fl...

Страница 27: ...Close lower louver panel O F F PILOT LO IH O N Piezo Ignitor Gas Control Knob Variable Control Knob Figure 51 Control Valve Operation Continued TO TURN OFF GAS TO APPLIANCE 1 Open lower louver panel 2 Set selector switch in the OFF position to prevent draining battery 3 Turn off all electrical power to appliance if service is to be performed 4 Push in gas control knob slightly and turn clockwise t...

Страница 28: ...urn on the hand held remote control 2 Press AUTO button to select this mode 3 Set the desired room temperature by pressing the TEMP or buttons 4 Press the POWER and LOCK buttons together to turn off the fireplace Note Do not leave the hand held remote in the AUTO mode close to the fireplace The radiant heat from the fireplace will turn off the fireplace Ideally place the hand held remote in the ce...

Страница 29: ...g and turn gas control knob back to PILOT The pilot will remain lit IMPORTANT To turn pilot off turn gas control knob on heater to the OFF position Operating optional blower accessory Locate blower controls by opening lower louver panel on fireplace Blower controls are located on the right side of switch bracket to the left just inside louver panel The BK manual blower and BKT thermostati cally co...

Страница 30: ...on Fireplace may need more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc GLASS DOOR WARNING Handle glass door panel with care Do not strike slam or otherwise abuse glass Do not operate fireplace with the glass door unlatched removed cracked or broken WARNING Do not use abrasive cleaners as this may damage glass Use a nonabra sive household glass cleaner to cl...

Страница 31: ...soft bristled brush to remove excess dust dirt or lint logs If you remove logs for cleaning refer to Installing Logs Lava Rock and Glowing Embers page 25 to properly replace logs Use a vacuum cleaner to remove any carbon buildup on logs Replace log s if broken See Replacement Parts on page 36 Replace ember material periodically as needed See Replacement Parts on page 36 venting system Conduct annu...

Страница 32: ...shutoff valve closed 2 Gas control knob not in PILOT position 3 Gas control knob not pressed in while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP models only 6 Pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ig...

Страница 33: ...ld pressure is too low 2 Burner porting or orifice clogged 1 Burner orifice is clogged or damaged 2 Damaged burner 3 Gas regulator defective 1 Residues from manufac turing processes and logs curing REMEDY 1 Press in gas control knob fully 2 After pilot lights keep gas control knob pressed in 30 seconds 3 Fully open equipment shut off valve 4 A Contact local natural or propane LP gas company B Clea...

Страница 34: ...nstalla tion REMEDY 1 Turn gas control knob to LO position and let warm up for a minute 2 Operate burner until air is removed from line Have gas line checked by local propane LP or natural gas company 3 Clean burner see Cleaning and Maintenance page 30 or replace burner orifice 1 Adjust log set so that the flame does not excessively impinge in it 2 Inspect the opening at the base of the burner to ...

Страница 35: ...ee Installing Logs Lava Rock and Glowing Embers page 25 2 Clean out air holes at burn er inlets Periodically repeat as needed 3 Remove blockage or re place burner 4 Have the vent system in spected including the ter mination cap Remove any restrictions or obstruction 5 Clear excess embers until a minimum gap of 1 2 remains under the grate OBSERVED PROBLEM Fireplace produces unwant ed odors Gas odor...

Страница 36: ...tallation operation or troubleshooting If so contact FMI PRODUCTS LLC at 1 866 328 4537 When calling please have your model and serial numbers of your heater ready You can also visit FMI PRODUCTS LLC s web site at www fmiproducts com V T32N A Series V T32N A HA Series CGDV32NR and CTDV32NR HA Rating 12 000 18 000 Btu Hr Type Gas Natural Gas Only Ignition Piezo Manifold Pressure Models V T32N A Ser...

Страница 37: ...n and off conveniently Wall mounted thermostat control kit gwmt1 Allowseasywallaccessfor thermostatic opera tion of your fireplace Wall mounted on off switch gwmS2 Allows burner system to be turned on and off with a wall switch NOTICE All accessories may not be available for all fireplace models Purchase these accessories from your local dealer If they can not supply these accessories call FMI PRO...

Страница 38: ...16646 01J 38 6 7 21 18 19 10 13 2 12 20 8 22 2 22 6 22 4 22 5 22 3 22 1 1 14 9 11 17 15 4 5 16 3 Parts Models V T32N A V T32NB A V T32NR A V T32NRB A V T32P A V T32PB A V T32PR A V T32PRB A CGDV32NR CGDV32PR and CTDV32NR HA ...

Страница 39: ...ge 40 41 1 10 108890 01 108890 01 Burner Base Gasket 1 11 109082 03 109082 03 Heat Shield 1 12 108897 01 108897 01 Rear Refractory Brick Panel B Models Only 1 13 108901 01 108901 01 Right Refractory Brick Panel B Models Only 1 14 108901 02 108901 02 Left Refractory Brick Panel B Models Only 1 15 11418 11418 Push On Nut 2 16 12125 12125 Screen 2 17 109479 01 109479 01 Screen Rod 1 18 14123 14123 St...

Страница 40: ...ucts com 116646 01J 40 3 2 1 13 14 18 15 16 4 5 7 8 6 9 12 10 11 17 19 PARTS Burner assembly Models V T32N A V T32NB A V T32NR A V T32NRB A V T32P A V T32PB A V T32PR A V T32PRB A CGDV32NR CGDV32PR and CTDV32NR HA ...

Страница 41: ...7 1 104506 02 Orifice Propane LP 55 1 12 104509 02 Aluminum Tubing Assy 1 13 26808 Valve Bracket 1 14 26827 Switch Bracket 1 15 108886 01 Base Grate Assembly 1 16 108891 01 Burner 1 17 108084 02 Pilot Assembly Natural 1 108084 03 Pilot Assembly Propane LP 1 108084 05 Pilot Assembly NG High Altitude 1 18 Burner Base Assembly 1 19 27113 Air Deflector 1 Not a field replaceable part PARTS Burner assem...

Страница 42: ...______ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _______________...

Страница 43: ...______ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _____________________________________________________ _______________...

Страница 44: ...is product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs associated with warranty repairs unless expressly covered by this warranty are not reimbursable under this warranty and are the responsibility of the owner Excluded ...

Отзывы: