SPECIFICATIONS
42"
36
1
/
4
"
33
1
/
4
"
22
1
/
8
"
6
3
/
4
"
7
3
/
4
"
9
3
/
8
"
3"
36"
41"
1"
J-Box
Access
RH SIDE VIEW
LH SIDE VIEW
Gas Line Conduit
Sleeve (Both Sides)
1/2" Air Space
Back and Sides
0" To Top
Spacer
Round Top Termination
Storm Collar
Flashing
Firestop
1" Airspace
To Combustible
Materials
Combustible
Wall Board
No Combustible
Material On Face
Not Less Than 14"
To Perpendicular
Sidewall
Hearth Extension
52" x 16"
0" To
Bottom
8" Each
Side
22
1
/
16
"
5/8"
13"
Rear View
of Fireplace
Opening for
Outside Air
Firestop
Thimble
9
1
/
2
"
14"
14"
FIREPLACE INSTALLATION
SELECTING LOCATION
To determine the safest and most efficient
location for the fireplace, you must take into
consideration the following guidelines:
1. The location must allow for proper clear
-
ances (see Figures 1 and 2, page 4).
2. Consider a location where the heat output
will not be affected by drafts, air condition
-
ing ducts, windows or doors.
3. A location that avoids the cutting of
joists or roof rafters will make installation
easier.
4. An outside air kit is available with this
fireplace (see
Outside Air Kit
on page 6).
WARNING: Do not install this
appliance in a bedroom.
f i r e - p a r t s . c o m