background image

www.fmiproducts.com

125271-01A

3

Millivolt Valves

The remote receiver is connected to the millivolt 
valve using the TH (thermostat) terminals on the 
terminal block on the gas valve. Connect wires from 
the remote receiver to the gas valve.
Operation of the remote receiver is similar to that 
of a thermostat in that both turn the gas valve on 
and off based on input signals. A thermostat's input 
signals are different temperatures. The remote re-
ceiver's input signal comes from the transmitter.
Connect  each  of  the  two  wires  leading  from  the 
TH  terminals  on  the  millivolt  gas  valve  to  either 
of the two wire terminals on the remote receiver. 
Normally  it  does  not  matter  which  wire  goes  to 
which terminal.

Electronic Spark Ignitions

The remote control receiver can be connected, in 
series, to a 24VAC transformer to the TR (trans-
former) terminal on the electronic module. Connect 
the hot wire from the 24VAC transformer to either 
of the wire terminals on the remote receiver. Con-
nect another wire (not included) between the other 
receiver  wire  terminal  and  the  TH  (thermostat) 
terminal on the electronic module.

TERMINAL BLOCK

ON MILLIVOLT

GAS VALVES

TH

TP

TP

TH

THERMOPILE/

PILOT LIGHT

REMOTE

RECEIVER

Figure 6: Millivolt Wiring Diagram

ELECTRONIC MODULE

TR

TH

REMOTE

RECEIVER

neutral wire

24VAC

hot wire

120VAC

110/24VAC

Transformer

OPERATION

MILLIVOLT VALVES

Light your gas appliance following the lighting in-

VWUXFWLRQVWKDWFDPHZLWK\RXUDSSOLDQFH&RQ¿UP
WKDWWKHSLORWÀDPHLVRQLWPXVWEHLQRSHUDWLRQIRU

the main gas valve to operate.

Slide  the  3-position  button  on  the  remote 

‡

receiver  to  the  ON  position.  The  main  gas 

ÀDPHVKRXOGLJQLWH

Figure 7: Electronic Wiring Diagram

6OLGH WKH EXWWRQ WR 2)) 7KH ÀDPH VKRXOG

‡

H[WLQJXLVKWKHSLORWÀDPHZLOOUHPDLQRQ

Slide the button to REMOTE (the center posi-

‡

tion), then press the ON button on the remote 
control to change the system to ON. The main 

JDVÀDPHVKRXOGLJQLWH

Electronic Spark Ignitions

Slide the 3-postion button on the remote re-

‡

ceiver to the ON position. The spark electrode 
should begin sparking to ignite the pilot (the 
pilot may ignite after only one spark). After the 

SLORW ÀDPH LV OLW WKH PDLQ JDV YDOYH VKRXOG
RSHQDQGWKHPDLQJDVÀDPHVKRXOGLJQLWH
6OLGHWKHEXWWRQWR2))7KHPDLQJDVÀDPH

‡

DQGSLORWÀDPHVKRXOGERWKH[WLQJXLVK

Slide the button to REMOTE (the center posi-

‡

tion), then press the ON button on the remote 
control to change the system to ON. The spark 
electrode should begin to ignite the pilot. After 
the pilot is lit, the main gas valve should be 

RSHQDQGWKHPDLQJDVÀDPHVKRXOGLJQLWH

MATCHING SECURITY CODES

Each remote control can use one of 65,536 unique 
security codes. It may be necessary to program 
the remote receiver to "LEARN" the security code 
of the remote control upon initial use, if batteries 
are replaced or if a replacement remote control 
is  purchased  from  your  dealer.  When  matching 
security  codes,  be  sure  the  slide  button  on  the 

UHFHLYHU LV LQ WKH 5(027( SRVLWLRQ WKH FRGH

will not "LEARN". If the slide switch is in the ON 
or  OFF  position.  Program  the  remote  receiver 
to "LEARN" a new security code by pushing the 
LEARN button on the top of the remote receiver 
and then pressing the MODE button on the remote 
control. A change in the beeping pattern, at the 
receiver, indicates the remote control's code has 
been programed into the receiver. When an exist-
ing receiver is matched to a new remote control, 
the new security code will override the old one. 
The  microprocessor  that  controls  the  security 
code matching procedure is controlled by a tim-
ing function. If you are unsuccessful in matching 

WKH VHFXULW\ FRGH RQ WKH ¿UVW DWWHPSW ZDLW 

minutes before trying again. This delay allows the 
microprocessor to reset its timer circuitry and try 
up to two or three more times. 

Отзывы: