2
118843-01
REV. B
02/11
2701 S. Harbor Blvd.
Santa Ana, CA 92704
1-866-328-4537
www.fmiproducts.com
Figure 3 - Routing and Installing Flexible Gas Line for 18'' Models
(Log Set Not Shown For Clarity)
5. 18'' Models Only:
To assemble nex flex line, insert flex tube into
end of compression nut with small opening. Place sleeve over
end of flex tube and into compression nut. Repeat for other end.
Attach new flexible gas line to valve and burner routed through
grate as shown in Figure 3. It is very important that you route
the flex line through the back leg on the grate. It could interfere
with placement in fireplace if routed around leg.
Checking Gas Connections
WARNING: Test all gas piping and connections, in-
ternal and external to unit, for leaks after installing or
servicing. Correct all leaks at once.
WARNING: Never use an open flame to check for a
leak. Apply a noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak. Correct all leaks
at once.
See your owner's manual for complete instructions on checking
your gas connections.
Sleeve
Compression Nut
Compression
Nut
Sleeve
Burner
Valve