background image

2

118843-01

REV. B

02/11

2701 S. Harbor Blvd.

Santa Ana, CA 92704

1-866-328-4537

www.fmiproducts.com

Figure 3 - Routing and Installing Flexible Gas Line for 18'' Models 

(Log Set Not Shown For Clarity)

5.  18'' Models Only:

 To assemble nex flex line, insert flex tube into 

end of compression nut with small opening. Place sleeve over 

end of flex tube and into compression nut. Repeat for other end. 

Attach new flexible gas line to valve and burner routed through 

grate as shown in Figure 3. It is very important that you route 

the flex line through the back leg on the grate. It could interfere 

with placement in fireplace if routed around leg.

Checking Gas Connections

 WARNING: Test all gas piping and connections, in-

ternal and external to unit, for leaks after installing or 

servicing. Correct all leaks at once.

 WARNING: Never use an open flame to check for a 

leak. Apply a noncorrosive leak detection fluid to all 

joints. Bubbles forming show a leak. Correct all leaks 

at once.

See your owner's  manual for complete instructions on checking 

your gas connections.

Sleeve

Compression Nut

Compression 

Nut

Sleeve

Burner

Valve

Отзывы: