FMI 36EMW-RBC Скачать руководство пользователя страница 2

www.fmiproducts.com

125192-01B

2

TABLE OF CONTENTS

Safety .................................................................. 2

Specifications

 ...................................................... 3

Fireplace Installation

............................................ 3

Venting Installation

 .............................................. 6

Optional Gas Line Installation

............................ 13

Finishing Fireplace

 ............................................ 15

Operation and Maintenance Guidelines

 ............ 15

Replacement Parts

 ............................................ 17

Technical Service

............................................... 17

Parts

 .................................................................. 17

Accessories

 ....................................................... 18

SAFETY

 CAUTION: The structural 

integrity of the mobile home 

floor  and  ceiling/roof  must  be 

maintained.

 WARNING: Do not install a 

fireplace insert in this box unless 

the manufacturer's instructions 

with the insert specifically state 

this fireplace has been tested for 

use with the insert.

FOR YOUR SAFETY

•  Do not store or use gasoline 

or any other flammable vapors 

or liquids in the vicinity of this 

or any other appliance.

•  Due to high temperatures, the 

appliance should be located 

out  of  traffic  and  away  from 

furniture and draperies.

•  Do not place clothing or other 

flammable materials on or near 

the appliance.

•  Never  leave  children  unat

-

tended when a fire is burning 

in the fireplace.

This fireplace is not intended to 

be used as a substitute for a fur-

nace to heat an entire home. Use 

for supplemental heat only.
This wood burning fireplace 

complies with the UL 127 stan-

dard as a FACTORY BUILT FIRE-

PLACE and is listed and tested 

by the PFS Corporation.

 WARNING: Improper instal-

lation, adjustment, alteration, 

service or maintenance can 

cause injury, property damage or 

loss of life. Refer to this manual 

for assistance or additional in-

formation.  Consult  a  qualified 

installer or local distributor.

IMPORTANT: Check HUD re-

quirements before installing this 

fireplace.

The 36EMW Series is specifically designed 

for use in manufactured mobile homes. These 

fireplaces  include  a  combustion  air  kit  and 

bi-fold doors.
Before  beginning  the  installation  of  the 

fireplace,  read  these  instructions  through 

completely.
•  This FMI PRODUCTS, LLC fireplace and 

its components are safe when installed 

according  to  this  installation  manual. 

Unless  you  use  FMI  PRODUCTS,  LLC 

approved components, which have been 

designed  and  tested  for  the  fireplace 

system, you may cause a fire hazard.

•  The FMI PRODUCTS, LLC warranty will 

be voided by and FMI PRODUCTS, LLC 

disclaims any responsibility for the follow

-

ing actions.
a.  Modification  of  the  fireplace,  com

-

ponents,  doors,  air  inlet  system  and 

damper control.

b.  Use of any component part not manu

-

factured or approved by FMI PROD

-

UCTS, LLC in combination with a FMI 

PRODUCTS, LLC fireplace system.

Proper installation is the most important step 

in  ensuring  safe  and  continuous  operation 

of  the  fireplace.  Consult  the  local  building 

codes  as  to  the  particular  requirements 

concerned with the installation of all factory 

built fireplaces. 

Содержание 36EMW-RBC

Страница 1: ...andard A vent free log can only be installed in an aftermarket completion of sale not for purpose of resale from the manufacturer permanently located manufactured mobile home where not prohibited by local codes Ap proved hood must be installed when using a vent free gas log heater see Accessories page 18 This firebox meets the construction and safety stan dards of H U D for application in mobile h...

Страница 2: ...PFS Corporation WARNING Improper instal lation adjustment alteration service or maintenance can causeinjury propertydamageor loss of life Refer to this manual for assistance or additional in formation Consult a qualified installer or local distributor IMPORTANT Check HUD re quirementsbeforeinstallingthis fireplace The 36EMW Series is specifically designed for use in manufactured mobile homes These...

Страница 3: ...ear View of Fireplace Opening for Outside Air Firestop Thimble 91 2 14 14 FIREPLACE INSTALLATION SELECTING LOCATION To determine the safest and most efficient location for the fireplace you must take into consideration the following guidelines 1 The location must allow for proper clear ances see Figures 1 and 2 page 4 2 Consider a location where the heat output will not be affected by drafts air c...

Страница 4: ...0 feet This measurement includes fireplace chim ney sections and height of termination assem bly at level of flue gas outlet see Figure 3 For manufactured home application minimum height is 11 for straight flue or flue with one elbow set Maximum height of any system is 20 Figure 3 Standard and Alternate Venting Installation Effective Height of Termination Cap Effective Height of Termination Cap RT...

Страница 5: ... must be fabricated to fit your required platform height Ember protector should extend under fireplace a minimum of 1 1 2 The ember protector should be made of metal material 6 Using screws or nails secure fireplace to framing through flanges located on sides of fireplace see Figure 4 HEARTH EXTENSION A hearth extension projecting a minimum of 16 in front of and a minimum of 8 beyond each side of ...

Страница 6: ...pleted during the rough framing of fireplace due to nature of its location The supplied flex duct measures approximately 10 compressed and up to approximately 36 extended Outside combustion air is accessed through mobile home floor using air kit model AK6E or a side wall using air kit model AK6 WE see Accessories on page 18 Installer may choose either left or right side mounting to allow for prope...

Страница 7: ...ill not be obstructed by bushes snow etc Locate vent near the fireplace to make flex duct installation easier CHIMNEY PIPE The chimney system approved for this fireplace consists of 12 18 24 36 and 48 snap lock double wall pipe segments planned for maximum adaptability to individual site requirements Actual lengths gained after fitting overlaps must be taken into consider ation lineal gain and are...

Страница 8: ... by pulling chimney upward after locking Chimney will not come apart if properly locked It is not neces sary to add screws to keep chimney together exception see Figure 14 page 11 ADJUSTABLE FIRESTOP THIMBLE FST A Adjustable Firestop ThimbleAssembly FST A is used to provide necessary air space and clearance between chimney pipe and insula tion in attic space of a manufactured home To install thimb...

Страница 9: ...y 12 A6 12 pitch means that the roof drops 6 for each 12 measured horizontally down from roof rafters 3 Use roof opening chart Figure 11 to determine correct opening length and flashing required 4 Remove shingles around opening mea sured Cut out this section 5 Add next sections of pipe until end pen etrates roof line Check to see that proper clearances are maintained Extend chim ney by adding sect...

Страница 10: ...e desired offset you may install combinations of 12 18 24 36 and 48 length of double wall pipe see offset chart and Figure 12 OFFSET CHART 22 50 FT SYSTEM HEIGHT Figure 13 Ceiling Support Pipe 12S 8DM Straps Straps Straps Straps Detail A Return Elbow Detail B Angle Firestop See Detail A See Detail B Figure 12 Elbow Offset B A Screws 2 Chimney weight above offset rests on return elbow Straps must b...

Страница 11: ...pacer with Living Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 FLASHING INSTALLATION V6F 8DM OR V12F 8DM Determine the flashing to be used with the roof opening chart Slide flashing over pipe until base is flat against roof Replace as many shingles as needed to cover exposed area and flashing base Secure in position by nail ing through shingles see Figure 1...

Страница 12: ... a vertical height difference of 18 see Figure 19 24 Min 24 Min 18 Min Typ Figure 19 Multiple Chase Installation Figure 17 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing Fireplace system must be terminated with listed round top termination In any case refer to installation instructions supplied with termi nation Terminations approved for this fireplace are RT 8DM and RTL 8DM Figu...

Страница 13: ...er or a qualified service person Note Before you proceed make sure your gas supply is turned off A gas line may be installed for the purpose of installing a vented or vent free appliance available through your local distributor Use only a 1 2 black iron pipe and appropriate fittings When installing a gas line a shutoff valve designed for installation outside appli ance is recommended 1 Remove knoc...

Страница 14: ... BYAQUALI FIED SERVICE PERSON Note Secure incoming gas line to wood fram ing to provide rigidity for threaded end If you wish to install an unvented vent free gas log set ONLY UNVENTED GAS LOG SETS WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD FOR UNVENTED ROOM HEATERS ANSI Z21 11 2 ARE TO BE INSTALLED IN THIS FIREPLACE Avent free log may be installed in an aftermar ket permanently located man...

Страница 15: ...3 GLASS DOORS Glass doors are standard with fireplace When fireplace is in operation doors must be FULLY OPENED or FULLY CLOSED position only or a fire hazard may be created see Figure 25 A fireplace equipped glass doors operates much differently than a fireplace with an open front Afireplace with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if ...

Страница 16: ...ly loosen lower pivot clips and upper spring clips Replace doors and fully close them Use 1 8 shims any material to level doors Once proper setting is achieved carefully open doors enough so that you can access spring clips with a phillips screwdriver Tighten screws See Figure 27 Figure 27 Adjusting Bi Fold Doors CLEANING GLASS Clean the glass with any commercial glass cleaner or soap and water Do...

Страница 17: ... Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty When calling or writing please have your model and serial numbers of your fireplace ready Model and serial number information are in the fireplace s rating plate located on the smoke shelf on the top right side of the fireplace opening OPERATION AND MAINTENANCE GUIDELINES Continued ...

Страница 18: ... Support Bracket Self Drilling Screws Cable Ferrule Eye Bolt Screw Strand Wire 50 ft FIRESTOP SPACER 3600FS 8DM 1 BI FOLD GLASS DOORS VDG36E Brushed Finish DP36E Platinum Finish VDBP36E Black Finish EMBER PROTECTOR 20093 GRATE 11116 BRICK LINER Rear PN 20029 Left Side PN 20030 Right Side PN 20030 Front Bottom PN 21242 Rear Bottom PN 21241 OPTIONAL OUTSIDE AIR KIT FOR FLOOR INSTALLATION 90154 Model...

Страница 19: ... installing a vent free gas log heater in this firebox ADJUSTABLE FIRESTOP THIMBLE FST A Includes Thimble PN 22383 Adapter Plate PN 22398 For Flat or 12 96 Pitch Ceilings Only Firestop PN 22377 ROUND TOP TERMINATION RTL 8DM 12 96 Pitch 30 144 Pitch 7 13 11 77 144 96 12 30 SQUARE CHASE TOP TERMINATION ETL 8DM ACCESSORIES Continued OPTIONAL OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION AK 6WE HEARTH EX...

Страница 20: ... 2 24 8DM 24 Double Wall Pipe 1 0 18 8DM 18 Double Wall Pipe 0 2 FST A Adjustable Firestop Thimble 1 1 V6F 8DM Roof Flashing 1 1 SC1 1 Storm Collar 1 1 RTL 8DM Round Cap Termination 1 1 Use for Most Common Manufactured Mobile Home Installations FACE EXTENSION FE 36R Front face extension would add 6 to the width and 6 to the height of the fireplace face FLEX DUCT 6 X 25 3 PACK MP6 75 AIR INLET HOOD...

Отзывы: