Mod. B4600Humid
5.
Starting up the unit
5.1
Electrical connection
Before connecting the unit to the power supply, check that the electrical grid characteristics match those described
in the technical characteristics.
The electrical installation must be performed by authorised technicians and meet the regulations in force.
Preferably, the electrical connection should be performed by mounting an electrical outlet (NOT INCLUDED) of
appropriate type and capacity for the maximum current absorbed by the oven phases. If not possible, it could be directly
connected to the circuit breaker on the electrical control board.
The recommended types of electrical connections are as follows:
400V three phase connection
directly connected to a circuit breaker:
400V three phase connection
connected to a three-phase power socket CETAC:
230V three phase connection
connected to a three-phase power socket CETAC:
In order to prevent damages from unintentional reset of the cutting thermal device, this unit should not be fed by an
external control device, such as timer, or be connected to a circuit whose supply is regularly interrupted.
An own power supply line protected by an adequately-sized circuit breaker switch and a fixed supply connection is
recommended to connect the units.
Observe the colour code of cables. Inappropriate connection may damage the unit.
CIRCUIT BREAKER
MATERIAL NOT SUPPLIED
MATERIAL NOT SUPPLIED