BATTERIES:

 

 

 

A battery compartment door allows easy access to the 9 Volt battery that powers the device. One 

alkaline 9 Volt "transistor" battery is used. If the unit will not power up the battery must be replaced by a fresh 9 
Volt battery. 
 

The battery is located in the case with access provided by a sliding plastic cover plate that has an arrow 

printed on it. Slide in the direction of the arrow to open. When replacing the cover, place it flat into the grooves so 
that both ends engage when closing. 

 

 

ENCLOSURE:

 

 

The comfort grip hand-held case is made of flame retardant ABS plastic with a flame rating of 94-5VA. 

The meter comes with an impact resistant rubber boot to protect it during daily use. 

 

 
AUXILIARY EQUIPMENT: 
 

 

The MC1, MC2, and MC3 are Protective Carry Cases to house and protect the HDFM-1 and your other test 

meters while being transported. These are very rugged water resistant ABS cases with foam-lined interiors suitable 
for transporting this meter and other test equipment. You can order these carry cases as an option. 
 
* 1080PsF is a high definition video format that has 1080 lines of vertical resolution using a Progressive Segmented 
Frame. The frame is sub-divided into two fields. One field is for the odd numbered lines and the other is for the 
even numbered lines. This format appears like an interlaced 1080i signal and this meter reads it as 1080i. 
 
 
 
 
 
 
 
 
 

 

HDFM-1isb 

 

 

 

 

 

 

 

 

 

 

 

PAGE 5 OF 5 

 

Содержание HDFM-1

Страница 1: ...HDFM 1 HIGH DEFINITION CAMERA FOCUS METER INSTRUCTION MANUAL IB 647701 ALL RIGHTS RESERVED ...

Страница 2: ...HDFM 1 TABLE OF CONTENTS DESCRIPTION METER OPERATION INPUT SIGNALS AND CONNECTORS DISPLAY FORMAT DISPLAY FOCUS CARE AND MAINTENANCE BATTERIES ENCLOSURE AUXILIARY EQUIPMENT HDFM 1isb PAGE 1 OF 5 ...

Страница 3: ... format and Lines of definition of the video signal and briefly displays that information on the LCD display then it goes into focus mode so you can set the maximum focus on the camera The ability to measure the video format and lines of definition can help you identify and verify any unfamiliar camera you come across in your work With the multi format cameras and DVRs available today it is easy t...

Страница 4: ...splay for fine tuning of the focus ring on the camera If there is movement in the scene you will see a small amount of change in the display this is caused by the information in the display changing and so the focus number will change slightly If the meter is being used with video un terminated you may see this display appear asking you to terminate the video input If you see this display put a 75...

Страница 5: ... meter is measuring information in the scene and will react to changes in the focus ring and also changes in the image or content of information in the scene If you have set the maximum focus on the camera and you put your hand up in front of the camera you will see the numbers and bar graph go down in focus This is caused by the loss of information caused by the change of in focus information Whe...

Страница 6: ... rating of 94 5VA The meter comes with an impact resistant rubber boot to protect it during daily use AUXILIARY EQUIPMENT The MC1 MC2 and MC3 are Protective Carry Cases to house and protect the HDFM 1 and your other test meters while being transported These are very rugged water resistant ABS cases with foam lined interiors suitable for transporting this meter and other test equipment You can orde...

Отзывы: