6     Low battery    Illuminated -  Control panel battery fault. (Call your alarm company)

     Flashing with a zone indicator  - A detector battery needs replacing.

Call

     your alarm company.

7     Tamper

      Illuminated  -  The control panel or external siren has been tampered

     or  incorrect pin numbers have been entered

      Flashing with a zone indicator  -   A detector has been tampered with.

    (Call your alarm company)

8     Signalling Illuminated-   A radio signal of a similar frequency is present for more

          than 45 seconds. If it continues call your alarm company.
Flashing with a zone indicator-   A  detector has failed to report.

   (Call your alarm company)

Flashing on its own  -   The telephone line is not operational.

  (If the line remains faulty call your alarm company)

 9      Zones 1 to 8

If an alarm has occurred they

indicate  which  detector  first

triggered

the alarm.

10    Panic

Indicates that a panic alarm has been operated.

11    Fire

Indicates that a fire sensor has operated.

ARMING THE ALARM SYSTEM WHEN LEAVING THE PREMISES

1.

Key in your 4 digit pin number. (Factory default is 1 2 3 4)

2.

Press Full set key

3.

The indicators illuminate to show which zones are being armed.
To add or remove a zone,  press the appropriate number key.

A flashing indicator means that a door has been left open.

4.

Vacate the protected area via your designated exit route.

5.

Wait for the exit timer bleep to stop.  The system is then armed.
If the bleep does not stop, return to the panel to identify where the fault is.

If the detectors are not clear to set,  i.e.. A door is still open. The affected zone
indicator will flash and will prevent arming until either the

door has been

closed

or that zone is omitted.

When armed all zone and fault indicators will be extinguished.

5

KEYPAD TAMPER
If incorrect attempts are made to enter the pin number, a tamper alarm will
operate,
(Internal audible in daytime.   Full alarm when armed).

TESTING YOUR ALARM SYSTEM
If your system incorporates an automatic telephone dialler going through to a
neighbour let your neighbour know you are carrying out a test .
If you have Police response via a Central Station connection, triggering the
alarm will not be acceptable to the Police.

Facility exists for you to test the detectors without causing a full alarm.

To select walk test:
1.

Key in your pin number

2.

Press the 9 key.

3.

Walk around the building triggering each detector.
Each time a detector is triggered a chime tone will be generated.

On return to the panel, the zone indicators will be illuminated, indicating which
zones have been triggered.
Pressing the Off  "0" key will clear the indicators.
PIR movement detectors have a 2 minute battery save timer. This means that
once it has sensed movement and transmitted its alarm signal, the detector
must see no movement for 2 minutes before it becomes active again.
Before testing PIR detectors ensure that no one has walked past them for 3
minutes.
A detector with a low battery will operate the internal audible alarm when
triggered.

To return the zone indicators to normal operation:
1.

Key in your pin number

2.

Press the 6 key.

In normal operation the zone lights indicate when a door is open and go out
again when the door is closed.
The panel will return to normal display next  time you arm the system in any case.

TESTING YOUR OUTSIDE BELLS / SIREN
Facility exists for you to test the outside bells.

To operate the bells for 10 seconds:
1.

Key in your PIN number

2.

Press the 4 key

3.

The outside siren will sound for approximately 10 seconds.

2