In META page PM, please click
RX Path Loss Setting
into
AGC PATH LOSS
setting page. Click
Upload from flash
button to read the RX path loss parameter form the mobile. If you have not loaded
the correct database file yet, META will notice you to open a database. Please follow it and then you
will see the target RX path loss parameters for different channels in the
AGC path loss
window.
Please note that all the RX loss values should be in the tolerance range of
+
/
-
5dB, otherwise it
Should be a hardware failure.
Содержание EZZY
Страница 1: ...FLY EZZY SERVICE MANUAL...
Страница 4: ...Chapter 2 Exploding Diagram The main board PCB...
Страница 5: ...The main board placement...
Страница 11: ...3 1 3 AD6548 Function Block Diagram...
Страница 16: ...1 Receiver Figure 3 2 5 Circuit of receiver 2 Louder speaker Figure 3 2 6 Circuit of louder speaker...
Страница 27: ...5 3 2 The features of META RF Tool PM PM is used for measuring the receiver Rx level at a given RX channel...
Страница 33: ...the MS burst Press GMSK level and ramp setting button into GMSK APC profile setting page...
Страница 35: ...If the Target MS TX function is OK you may see a TX PVT profile from the 8960 as follows...