background image

 

 

Mounting of the Fly meter: 

The display module 

is normally situated on the dashboard of your machine.  

Measurement module

 is mounted in the engine compartment within the reach of all measuring 

sensors. 

 

WARNING !!!! Do not attach the module to the hot spots to prevent module 

overheating. 

 

For interconnection of these modules use a data cable which is supplied in the length according to 

your needs. 

Other connecting cables

-  Temperature and fuel sensors connect to the fixed inputs  
-  Speed sensor connect to an appropriate input 
-  Minus of the battery connect the shortest way to the motor frame  
-  Plus of the battery can be connected 

to the measuring or display module

. It depends on the 

construction of your cabling. The device connects behind the main power switch; it means that 
when you turn on the main power switch this measuring device will turn on too.   
 

Do not connect the power into both modules simultaneously!!! 

 

Pay close attention to attachment of both data and connecting cables and sensor cables to 

avoid stress, disconnection and damage caused by vibration!!!  

 

We recommend to use sensors of our company because if you use different 

company’s 

products pay close attention to the selection to avoid damage of the measuring devise.  

 

If you do not use the fuel flow sensor from our company pay close attention to the selection. It 

is possible to use sensor only with NPN or PNP output. 

 

 

 

Содержание Fly Meter

Страница 1: ...fuel pressure fuel level fall of the on board voltage Backlight regulation The device is controlled by two buttons ESC escape used to exit the menu always one step back ENT enter used to enter the menu shifting in the menu to change values Long press serves for an access into the basic menu Short press serves for shifting between individual lines Confirm by a long press an access into the selected...

Страница 2: ...battery charging during flight when you set an appropriate value of the battery the fall below the set level will be indicated if the battery is not charging it will be highlighted on the display and the display will be flashing Anytime during the flight it is possible to switch off the light alarm by pressing a button ESC for 1 second Another triggered alarm will be lightly active and it is possi...

Страница 3: ...us of the battery can be connected to the measuring or display module It depends on the construction of your cabling The device connects behind the main power switch it means that when you turn on the main power switch this measuring device will turn on too Do not connect the power into both modules simultaneously Pay close attention to attachment of both data and connecting cables and sensor cabl...

Страница 4: ...phasis is on the close connection of the whole vacuum system to prevent air leak and fuel foaming The fuel filter must be used in front of the sensor and the sensor must be attached in a horizontal position After the sensor installation you must always perform a longer test of engine running at full speed to make yourself sure that you used a sensor with the required range flow and that there is n...

Страница 5: ...m Temp 1 Temp 2 Temp 4 Temp 3 Temp 5 Settings Maximum menu Burnup Temperat unit Activation temp sen sor Flow meter constant Consumption unit Fuel indicator Display settings setup Show values setup setup setup setup setup setup setup Show values Clear values setup setup setup setup setup setup Show and set values RPM s constant setup ...

Отзывы: