background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Attachment compressed-air motors F 416 

… 

9 / 20 

ENGLI

SH

 

>  Immerse the pump vertically into the liquid and secure it in a vertical position by the 
 

use of a barrel fitting or a screw clamp. 

>  Connect the service unit between the compressed air supply and the compressed air 

motor. 

>  Set the service unit to the desired operating pressure. 
>  Start the motor. 

 

 

Risk of injury! 

  Only start the motor when the pump is in the liquid. 

 

 

Attention! 

  Before connecting the air supply hose to the motor, set the 

Start/Stop switch to "0" (Stop).  

(On model F 416 Ex unlock locking mechanism of the on/off switch).  

Compressed air motor F 416-1 Ex starts immediately upon  
compressed air connection. 

  With compressed air motor F 416-2 Ex, close the ball valve  

before compressed air connection. 

 

>  When using air motors, please do not exceed the maximum operating pressure  

and use an air service unit. 

>  Install the air service unit in the order 

  water separator 

  pressure manometer 

  oil mist lubricator 

 
Prior to impinge with the pneumatic the following installation 
steps are to be made: 
 
>  Drain condensate. 
>  Check oil level. 
>  Set the oil mist lubricator to 2-3 drops per minute. 
>  Install oil separator. 
>  Use the supplied silencer or an exhaust air hose. 
>  Connect the air supply hose. 
>  Observe the operating pressure, if necessary readjust. 
>  Start the motor. 
 

 

4.1 

Lubricants for air service unit 

Use lubricants with the viscosity SAE 32-46. 

 

 

Fig 1: Air service unit 

Содержание F 416 EX

Страница 1: ...iginal attachment Annexe originale Druckluftmotoren F 416 EX F 416 1 EX F 416 2 EX Seite 3 6 Compressed air motors F 416 EX F 416 1 EX F 416 2 EX Page 7 10 Moteurs pneumatiques F 416 EX F 416 1 EX F 416 2 EX Page 11 14 ...

Страница 2: ...n operating instructions for drum and container pumps and the included product specific attachments before operating the pump Before pumping flammable liquids or when using the motor or the pump in a hazardous area be sure to read the attachment Ex Protection Drum and Container Pumps Attention Lisez la notice d instructions générale pour les pompes vide fûts ainsi que les annexes spécifiques aux p...

Страница 3: ...fende Antriebswelle Motoren nie ohne Pumpe betreiben Pumpe nicht unbeaufsichtigt lassen Pumpe so aufstellen dass sie nicht in den Behälter fallen kann Pumpe nur mit geeignetem Schlauch betreiben Pumpe nur bis unterhalb des Druckstutzens in die Flüssigkeit eintauchen Schlauch gegen Abrutschen vom Schlauchstecker sichern Achtung Druckluftmotoren nur mit mitgeliefertem Schalldämpfer oder Abluftschlau...

Страница 4: ...hrungsart und Belastung der Pumpe und somit des Motors variiert der Schallpegel 4 Montage und Inbetriebnahme Verletzungsgefahr Vor allen Montagearbeiten die Antriebsmaschine vom Druckluft versorgungsnetz trennen Verletzungsgefahr Pumpe nur in Betrieb nehmen wenn die Überwurfmutter zwi schen Pumpe und Motor von Hand fest angezogen ist Verletzungsgefahr durch Grat am Gewindeschnitt Bei der Mon tage ...

Страница 5: ...Ex läuft bei Anschluss an Druckluft so fort an Bei Druckluftmotor F 416 2 Ex Kugelventil vor Anschluss an Druckluft schließen Bei Druckluftmotoren max Betriebsdruck beachten und Wartungseinheit zur Aufbereitung der Druckluft verwenden Wartungseinheit in der Reihenfolge Wasserabscheider Druckmanometer Ölnebler montieren Vor dem Beaufschlagen mit der Pneumatik sind noch zusätzliche Montageschritte a...

Страница 6: ...plosionsgefährdeten Bereiches her stellen Der an dem Druckstutzen der Fasspumpe angeschlossene Schlauch darf einen Wider stand von 106 Ohm zwischen den Schlauchenden nicht überschreiten Nur Schlauchleitungen 3 mit leitfähigen Schlauchverschraubungen verwenden siehe TRbF 50 Anhang B R 106 Ω Entfernen Sie Farbe und Schmutz an den Anklemmstellen der Potentialausgleichsleiter und den Übergangsstellen ...

Страница 7: ...t Never operate motors without pump Never leave the pump unattended Position the pump to prevent it from falling into the container Only operate the pump with a suitable hose The pump should not be immersed deeper into the liquid than the outlet connection Secure the hose from sliding off the hose connector Attention Only operate compressed air motors with the silencer or exhaust hose provided wit...

Страница 8: ...andard silencer Sound power level LWA 95 dB A Depending on the design of the pump and the load of the pump and thus the engine the sound varies 4 Installation and Commissioning Separate engine from compressed air supply before installation Screw a silencer onto the compressed air motor Install a fine filter silencer or an exhaust hose Place the motor on the pump Risk of injury Only operate the pum...

Страница 9: ...F 416 1 Ex starts immediately upon compressed air connection With compressed air motor F 416 2 Ex close the ball valve before compressed air connection When using air motors please do not exceed the maximum operating pressure and use an air service unit Install the air service unit in the order water separator pressure manometer oil mist lubricator Prior to impinge with the pneumatic the following...

Страница 10: ...plo sion proof terminal box or outside of the hazardous area The hose connected to the pressure socket must not exceed a resistance of 106 Ohm between the hose ends Only use hose lines 3 with conductive hose unions see TRbF 50 Annex B R 106 Ω Remove paint and dirt from all connection points of equipotential bonding conductors and transition points of the containers to the electrically conductive b...

Страница 11: ...sans pompe Ne pas laisser la pompe sans surveillance Placer la pompe de façon à ce qu elle ne puisse pas tomber dans le contenant Ne faire fonctionner la pompe qu avec un flexible approprié Bien fixer le flexible pour l empêcher de se détacher de son raccord Plonger la pompe dans le liquide en veillant à ce que le raccord du tuyau de refoulement ne soit pas immergé Nuisance sonore Ne faire fonctio...

Страница 12: ... Niveau sonore 83 90 dB A mesuré avec silencieux standard Niveau de puissance acoustique LWA 95 dB A Selon la conception de la pompe et la charge de la pompe et donc le moteur le niveau sonore varie 4 Montage et mise en service Attention Avant de tous travaux de montage séparer le dispositif d entraînement de l alimentation de l air comprimé Visser le silencieux sur le moteur pneumatique Monter un...

Страница 13: ... moteur pneumatique 416 1 Ex se met en marche dès qu il est raccordé à l air comprimé Fermer le robinet sphérique du moteur pneumatique F 416 2 Ex avant de le brancher à l air comprimé Vérifier la pression de service maximale des moteurs pneumatiques et utiliser un filtre détendeur lubrificateur Monter le filtre détendeur lubrificateur dans l ordre suivant séparateur d eau manomètre pulvérisateur ...

Страница 14: ...rs de la zone à risque d explosion Le tuyau raccordé à la prise de pression ne doit pas dépasser une résistance de 106 Ohms entre les extrémités des tuyaux N utiliser que des conduites flexibles 3 dont les raccords à douille sont conducteurs voir TRbF 50 annexe B R 106 Ω Pour garantir une bonne conductivité retirer peinture et saletés se trouvant sur les bornes du conducteur d équipotentialité et ...

Страница 15: ...F 416 Ex 15 20 5 EU Konformitätserklärung EU Declaration of Conformity Déclaration de conformité CE ...

Страница 16: ...___ 16 20 F 416 Ex ...

Страница 17: ...___ F 416 Ex 17 20 ...

Страница 18: ...___ 18 20 F 416 Ex ...

Страница 19: ...___ F 416 Ex 19 20 ...

Страница 20: ...FB 10 98000005_06 0419 1 DEF ...

Отзывы: