Actuator Adjustments
1
Hold actuator in place. Use 4-in-1
tool to loosen set screw by turning
counter-clockwise, approximately
4 rotations. Do not remove set screw.
2
Adjust actuator UP (counter-
clockwise) if there is too much travel
in push button, or if toilet does not
flush completely. Adjust actuator
DOWN (clockwise) if there is not
enough travel in push button, or if
toilet runs for more than 1 minute.
Adjustment complete
29