DC Inverter U-match Series Floor Ceiling Type Unit
52
5.3.1 Clean Air Filter
(1) Disassembly method of filter screen and electric box cover
How to clean the air filter
①
Open the air inlet grille.
a) Firstly unfix two buckles on the grille as
shown on the picture.
b) Remove the screws under the buckles by
a screwdriver and then open the inlet
grille.
②
Clean the filer screen.
Clean the filer screen by a vacuum
cleaner or wash it by flashing water. If the oil
stain on the filter can not be removed or
cleaned up, wash it by warm water meld with
the detergent. Dry the filer in the shadow.
Notice:
a) Never use hot water over 45°C in case of
color fading or turning yellow.
b) Never dry it by fire so as to prevent the
filter caught fire or deformation.
③
Disassemble the left and right side board.
a) After the grille is removed, use a
screwdriver to remove the screws shown
on the picture.
b) Push the side plate as per the arrowed
direction and take it down.
④
Disassemble the right side board.
Disassembly method of right
side board Step 3.
⑤
Disassemble the electric box cover
After the right side board is removed, the
electric box cover will be shown up and
disassemble the fixed screws on it.