background image

N E T W O R K

S U P E R

V I S I O N

Fluke Networks

P.O. Box 777, Everett, WA USA 98206-0777

Fluke Networks

 operates in more than 50 countries 

worldwide. To fi nd your local offi ce contact details, go to 

www.fl ukenetworks.com/contact

.

©

2006 Fluke Corporation. All rights reserved. 

Printed in U.S.A. 2/2006 264xxxx D-ENG-N Rev A

What are ASEs?

ASEs (Analysis Service Elements) are data 

collection and network performance monitor-

ing hardware devices placed on a wide area 

network (WAN) or Local Area Network (LAN) 

as part of the Visual UpTime Select system,

which offers in-depth, real-time, and historical 

visibility into the performance of your 

applications infrastructure. In the system, 

data gathered by ASEs is stored in the Visual 

UpTime Select server and displayed and ana-

lyzed from the Visual UpTime Select Web client. 

As a service level management tool, ASEs 

indicate when services are being met, provide 

warnings when services start to degrade, and 

send alerts when services are not met.

Hardware Warranties

Enhanced Gold, Bronze, and International 

Gold ASE hardware warranty service programs 

are available to help you maximize your 

investment in Visual UpTime Select. For more 

detailed warranty information, visit:

www.fl ukenetworks.com/visualcustomercare

Ordering Information

For more details, please contact your Visual 

UpTime Select authorized reseller or 

Fluke Networks Sales at (800) 240-4010 

or (301) 296-2300.

T1 CSU/DSU ASE specifcations 

General

Dimensions

8.16” (20.7 cm) x 9.0” (22.8 cm) x 1.62”(4.1 cm)
Plastic case with internal power supply.

Weight

2.10 lbs.

Data Rate

1.544 Mbps synchronous

Timing Mode 

Derived externally from the T1 network or DSX-1 
interface, or internally from the ASE.

Environment

Operating Temperature

0

o

 to +40

o

C (+32

o

 to +104

o

 F)

Storage Temperature

-20

o

 to +55

o

C (-4

o

 to +131

o

×F)

Clearance Requirement

Minimum of 3” (7.62 cm) space on sides.

Operating and Storage 
Humidity

10% to 90%, noncondensing

Power Requirements

Input

100 to 240 VAC

Frequency 50/60 

Hz

Input Current Rating

0.5 amps

T1 Network Interface

Line Rate

1.544 Mbps ±50 bps synchronous

Line Format

AMI or B9ZS line coding

Framing

ESF or D4 framing formats

ESF FDL

ANSI T1.403, AT&T TR54016, Both, or None

Input Signal 

0dB to -36dB

Output Signal

0, -7.5dB, -15dB, -22.5dB LBO

Pulse Density

AT&T 62411

Connector

8-pin modular jack—USOC: RJ48C

Timing

Loop, DSX-1, or Internal

Channel Selection

1 to 24 channels in any combination

Network DTE Interface 
(Data Port)

Confi guration

DCE for interfacing with DTE

Data and Clock Leads

ITU-T V.35

Signaling Leads

EIA RS-232 (ITU-T V.28)

Data Rates

56 kbps x N or 64 kbps x N (N = 1 through 24)

HDLC Inversion

Selectable V.35 data inversion

Transmit Timing Basis

Network selected-source timing

Receive Timing Basis

SCT, inverted SCT, SCTE

Receive Line Data Not Valid

RLSD, CTS

Connector

Female 34-pin V.35 connector

DSX-1 Interface

Line Rate

1.544 Mbps ±50 bps 

Line Format

AMI or B8ZS 

Framing

ESF or D4 (SF)

Input Signal

-1dB to -11dB

Line Equalization

0 ft, 133 ft, 266 ft, 399 ft, 533 ft, 655 ft

Connector

RJ-45

Channel Selection

1 to 24 channels in any combination

Serial Port Interface

Specifi cations

19200 or 9600 bps baud rate, 8 data bits no parity, 
1 stop bit, EIA RS-232 DTE electrical format, RJ-45 
connector

Ethernet 10/100BaseT 
Interface

Bite Rate

10 or 100 Mbps

Connector

8-pin modular jack: RJ-48

Содержание Visual UpTime Select 807-0100

Страница 1: ...ntaining full wire speed pass through of all traffic In its initial release the ASE supports IP Transport software over MultiLink Point to Point Protocol MLPPP T1 links The 4xT1 E1 ASE includes LinkSa...

Страница 2: ...s Sales at 800 240 4010 or 301 296 2300 4xT1 E1 inline probe ASE specifcations General Dimensions 8 16 20 7 cm x 9 0 22 8 cm x 1 62 4 1 cm Weight 7 lbs Data Rate T1 1 536 Mbps E1 1 984 Mbps Timing Mod...

Страница 3: ...d networks that use IP switching The ASE also includes LinkSafe technology to protect circuit integrity in case of an ASE outage as well as power failure notification When configured for use on an E1...

Страница 4: ...orks Sales at 800 240 4010 or 301 296 2300 T1 E1 inline probe ASE specifcations General Dimensions 8 16 20 7 cm x 9 0 22 8 cm x 1 62 4 1 cm Weight 2 10 lbs Data Rate 1 544 Mbps synchronous Timing Mode...

Страница 5: ...deployment options The IP Transport Ethernet ASE is typically deployed as an inline probe on the access line between LAN devices such as the LAN switch and router see figure Other options include pos...

Страница 6: ...alerts when services are not met Hardware Warranties Enhanced Gold Bronze and International Gold ASE hardware warranty service programs are available to help you maximize your investment in Visual UpT...

Страница 7: ...loyment options The IP Transport Ethernet ASE is typically deployed as an inline probe on the access line between LAN devices such as the LAN switch and router see figure Other options include posi ti...

Страница 8: ...lerts when services are not met Hardware Warranties Enhanced Gold Bronze and International Gold ASE hardware warranty service programs are available to help you maximize your investment in Visual UpTi...

Страница 9: ...ransport and LAN Visibility software Designed for business class DSL and cable the 10 100 1000 Ethernet ASE has a wide variety of deployment options The IP Transport Ethernet ASE is deployed off a LAN...

Страница 10: ...de and send alerts when services are not met Hardware Warranties Enhanced Gold Bronze and International Gold ASE hardware warranty service programs are available to help you maximize your investment i...

Страница 11: ...ployment in standard frame relay or HDLC networks and IP Transport software for deployment in frame relay or HDLC based networks that use IP switching The ASE also includes LinkSafe technology to prot...

Страница 12: ...nty service programs are available to help you maximize your investment in Visual UpTime Select For more detailed warranty information visit www flukenetworks com visualcustomercare Ordering Informati...

Страница 13: ...Transport software for deployment in frame relay or HDLC based networks that use IP switching The V 35 inline probe ASE supports V 35 connectiv ity through a V 35 Data Terminal Equipment DTE interface...

Страница 14: ...networks com visualcustomercare Ordering Information For more details please contact your Visual UpTime Select authorized reseller or Fluke Networks Sales at 800 240 4010 or 301 296 2300 V 35 inline p...

Страница 15: ...s and IP Transport software for deployment in frame relay or HDLC based networks that use IP switching The ASE supports X 21 connectivity through a X 21 Data Terminal Equipment DTE interface on the ne...

Страница 16: ...your Visual UpTime Select authorized reseller or Fluke Networks Sales at 800 240 4010 or 301 296 2300 X 21 inline probe ASE specifcations General Dimensions 8 16 20 7 cm x 9 0 22 8 cm x 1 62 4 1 cm P...

Страница 17: ...TM based networks that use IP switching The ASE also includes LinkSafe technology to protect circuit integrity in case of an ASE outage as well as power failure notification The DS3 inline probe ASE i...

Страница 18: ...you maximize your investment in Visual UpTime Select For more detailed warranty information visit www flukenetworks com visualcustomercare Ordering Information For more details please contact your Vi...

Страница 19: ...networks that use IP switching The ASE also includes LinkSafe technology to protect circuit integrity in case of an ASE outage as well as power failure notification The E3 inline probe ASE is designe...

Страница 20: ...e programs are available to help you maximize your investment in Visual UpTime Select For more detailed warranty information visit www flukenetworks com visualcustomercare Ordering Information For mor...

Страница 21: ...orks that use IP switching The ASE also includes LinkSafe technology to protect circuit integrity in case of an ASE outage as well as power failure notification The OC 3c STM 1 inline probe ASE is des...

Страница 22: ...ormation visit www flukenetworks com visualcustomercare Ordering Information For more details please contact your Visual UpTime Select authorized reseller or Fluke Networks Sales at 800 240 4010 or 30...

Страница 23: ...s that use IP switching The ASE also includes LinkSafe technology to protect circuit integrity in case of an ASE outage as well as power failure notification The OC 3c STM 1 inline probe ASE is design...

Страница 24: ...more detailed warranty information visit www flukenetworks com visualcustomercare Ordering Information For more details please contact your Visual UpTime Select authorized reseller or Fluke Networks S...

Страница 25: ...nterfaces The ASE supports Multi Protocol software for deploy ment in standard frame relay or HDLC networks and IP Transport software for deployment in frame relay or HDLC based networks that use IP s...

Страница 26: ...s Data Rate 1 544 Mbps synchronous Timing Mode Derived externally from the T1 network or DSX 1 interface or internally from the ASE Environment Operating Temperature 0 o to 40 o C 32 o to 104 o F Stor...

Страница 27: ...d provides connectivity through V 35 interface The ASE supports Multi Protocol software for deploy ment in standard frame relay or HDLC networks and IP Transport software for deployment in frame relay...

Страница 28: ...ations General Dimensions 8 16 20 7 cm x 9 0 22 8 cm x 1 62 4 1 cm Plastic case with internal power supply Weight 2 10 lbs Data Rate 1 544 Mbps synchronous Timing Mode Derived externally from the T1 n...

Страница 29: ...he ASE supports Multi Protocol software for deploy ment in standard frame relay or HDLC networks and IP Transport software for deployment in networks that use IP switching This ASE features an interna...

Страница 30: ...9 0 22 8 cm x 1 62 4 1 cm Plastic case with internal power supply Weight 2 10 lbs Data Rate 1 544 Mbps synchronous Timing Mode Derived externally from the T1 network or DSX 1 interface or internally...

Страница 31: ...signal DSX 1 interfaces The ASE supports Multi Protocol software for deploy ment in standard frame relay or HDLC networks and IP Transport software for deployment in networks that use IP switching The...

Страница 32: ...Derived externally from the T1 network or DSX 1 interface or internally from the ASE Environment Operating Temperature 0 o to 40 o C 32 o to 104 o F Storage Temperature 20 o to 55 o C 4 o to 131 o F C...

Страница 33: ...port Dual analysis T1 CSU DSU ASE is deployed on a T1 access line at the demarcation point between the provider network and customer premises It supports frame relay HDLC and IP Transport capabilities...

Страница 34: ...s Data Rate 1 544 Mbps synchronous Timing Mode Derived externally from the T1 network or DSX 1 interface or internally from the ASE Environment Operating Temperature 0 o to 40 o C 32 o to 104 o F Stor...

Отзывы: