5 Installation
In this section you will learn how to mount the system and how to establish the electrical connections. Information
about installing the sensors on site can be found in the instructions for the respective sensors. For PRUFTECHNIK
sensors these are:
Installation instructions for IEPE-type sensors VIB 9.833
5.1 Preparation
For proper installation you, as the operator, must ensure that the following conditions are met and that the fol-
lowing preparations are made on site:
Ambient conditions
Temperature
-20°C to +60°C [-4°F ... +140°F] (system in protective housing)
-20°C to +70°C [-4°F ... +158°F] (system without protective housing)
Rel. humidity
max. 95% (25 °C [77°F ], no condensation)
Altitude
max. 2000 m [6562 ft.]
Installation site
Indoor installation (no direct sunlight)
EMC
There must be no strong electromagnetic fields in the immediate vicinity of the sys-
tem, e.g. in the vicinity of a generator or a high voltage cable.
Connections
Power supply
100 - 240 V AC / 1.3 A / 50 to 60 Hz
Network
Ethernet TCP/IP / 100 Mbit
Connecting cables, general requirements
Temperature range
-20°C to +80°C [-4°F ... +176°F]
Flammability
flame retardant according to UL 2556 VW-1 or equivalent (IEC 60332-1-2 / IEC
60332-2-2)
Shielded cable
shielding > 85%