3-39
Recording
Ending the measurement recording
The measurement recording is ended when
- the stop condition is fulfilled
- the ESC button is pressed
- the memory card is full
- the maximum number of results is reached (65535).
Special cases
The recording function is used in a wide range of applications and
is intuitive in use. However, the following special characteristics
should be noted:
What happens if the device shuts down due to a fault?
If the battery should run out during measurement, the device saves
the measurement data prior to the emergency shut-off. If a fault
arises during measurement, the saved results are retained.
Shock pulse measurement
Before beginning recording, enter the normalization parameters.
This normalization then applies to the entire measurement
duration. Note: rpm-controlled recording is only possible without
normalization.
Trending spectrum
To be able to record the measurement values in a trending
spectrum, the recording function is also available in the 'Machine
template' mode. Recording is configured and started as described in
the previous section.
Special characteristics:
- The trending spectrum is integrated in a machine template
(OMNITREND software).
- In addition to the trending spectrum, the machine template can
contain all measurement types permissible for the recording.
- Recording is only possible in the template without a 'Production
test' (see also p. 3-14).
- After the recording, all actions that are triggered automatically
are disabled in the template (e.g. starting the next task).
- The recording configuration is not saved with the result.
- Multiple datasets can be added to a file.