Operation

Speaker Timeout

The speaker draws more current from the battery than 
any other circuit on the test set. The battery will be 
drained quickly if the speaker is left on continuously. To 
extend battery life, the test set has a timeout function 
that automatically turns off the speaker when the test 
set is on-hook. A timer is started whenever the test set 
is put on-hook. As long as the test set is off-hook the 
timer will not start. 

If the test set is used as a handset in Monitor mode and 
if the test set’s receiver has been set to high volume, 
the battery will be asked to deliver enough current to 
drain the battery sooner than desired. So the same 
timeout that is applied to the speaker is applied to the 
high volume state in Monitor mode. If the test set is in 
Monitor mode with the receiver’s volume set to high 
volume, after the timeout the test set will revert to low 
volume. When the test set is in Monitor mode with the 
speaker off and with the receiver volume set to low, it 
draws very little current from the battery.

The speaker timeout duration is programmable while 
on-hook and 240 minutes (4 hours) while off-hook. The 
off-hook timeout cannot be changed. Remember, the 
longer the selected timeout duration the shorter the 
battery life. 

To change the speaker timeout duration:

1

Set the Talk/Monitor switch to M.

2

Press the STORE/PROG key.

3

Press the SPKR key. 

4

Press a number key to select a duration. Invalid 
entries are ignored. The test set gives a 
confirmation tone when the entry is accepted.

Factory Defaults

The Restore Defaults function lets you restore all 
programmable features to their original factory 
settings. This function does not clear stored telephone 
numbers. The defaults are as follows:

Pause Duration: 4 seconds

Hook Flash Duration: 600 ms

Speaker Timeout: 2 minutes

Exclusive Only Loud Speaker: Disabled

To restore the factory default values:

1

Set the Talk/Monitor switch to M.

2

Press the STORE/PROG key.

3

Press the pound (#) key. The test set provides a 
confirmation tone when the entry is accepted.

Key

Speaker Timeout Duration

 2 minutes (default)

 5 minutes

3  

10 

minutes

4  

20 

minutes

5  

30 

minutes

6  

40 

minutes

Содержание TS 42DLX

Страница 1: ...TS 42DLX Deluxe Test Set Users Guide PN 2460934 October 2005 2005 Fluke Corporation All rights reserved Printed in China All product names are trademarks of their respective companies...

Страница 2: ...or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authori...

Страница 3: ...ing the Test Set in Talk Mode 9 Originating a Call 9 Disconnecting a Call 9 Answering a Call 9 Ground Start 9 Data Safe Practices 10 High Voltage Lockout Operation 10 Configuring Your Test Set 10 Last...

Страница 4: ...Set Users Guide ii Maintenance 14 Replacing the Battery 14 Replacing or Relocating the Belt Clip 15 Replacing the Line Cord 15 Removing the Old Line Cord 15 Installing a New Line Cord 16 Accessories 1...

Страница 5: ...ities as voice services It is not always easy to tell the difference between data and voice services The TS42DLX Deluxe Test Set incorporates unique patented circuitry that prevents disruption of digi...

Страница 6: ...ckout in Talk Mode Software Upgradable Physical Characteristics Housing See Figure 1 The TS42DLX Deluxe Test Set housing is made of high impact plastic The test set provides rugged service and withsta...

Страница 7: ...be restricted by local laws The test sets battery compartment makes battery replacement easy See Replacing the Battery on page 14 Note If the test set fails to operate properly first replace the batt...

Страница 8: ...circuit in the test set The battery lasts longer if the speaker is used in moderation Audio Controls See Figure 2 The three audio control keys are located on the inside handle of the test set between...

Страница 9: ...the MUTE LED will flash VOL Volume Pressing the VOL key switches the sound level of the test set s active receiver between normal and high volume This is true in Monitor mode as well as Talk mode The...

Страница 10: ...Dialing Numbers on page 11 FLASH Hook Flash key The FLASH key is used to interrupt loop current for a timed duration The FLASH key only operates when the test set is off hook When pressed the FLASH k...

Страница 11: ...ED corresponding to the line polarity will flash for 5 seconds If the loop current is normal the LED will light solid Low loop current may indicate a problem on the line Light Emitting Diodes LEDs All...

Страница 12: ...n puts the test set into Monitor mode Using the Test Set in Monitor Mode While in Monitor mode the test set is always on hook The test set draws no direct current from the line and it transmits no sig...

Страница 13: ...h to T 6 If talk battery is present the test set will go off hook and draw dial tone Note The test set will not go off hook if the line voltage exceeds 140 V 7 Dial the desired number Disconnecting a...

Страница 14: ...ng off hook on a line carrying a high DC voltage can damage the power supply feeding the line To prevent this from occurring the TS42DLX Deluxe provides an automatic high voltage lockout function When...

Страница 15: ...red memory location The test set gives a confirmation tone Storing a Number You are Calling 1 Connect the test set to a working telephone line set the TALK MONITOR switch to TALK and receive dial tone...

Страница 16: ...e for the second dial tone to be returned The pause duration can be programmed To change the PBX Pause duration 1 Set the Talk Monitor switch to M 2 Press the STORE PROG key 3 Press the PAUSE key 4 Pr...

Страница 17: ...volume set to low it draws very little current from the battery The speaker timeout duration is programmable while on hook and 240 minutes 4 hours while off hook The off hook timeout cannot be changed...

Страница 18: ...good 9 V alkaline or lithium battery or the test set will not operate properly 1 Disconnect the test set from the line and place on a flat work surface with battery cover up Note Battery cover screws...

Страница 19: ...d can be replaced by the user To order a replacement line cord contact your local Fluke Networks authorized distributor See Accessories on page 17 for line cord model numbers WWarning Read all instruc...

Страница 20: ...ide of the screw lugs is up see Figure 9 and that the line cord screw lugs are flush against the circuit board Note Do not over tighten screws Over tightening will strip the plastic 2 Fasten the red w...

Страница 21: ...order accessories contact your local Fluke Networks distributor Description Fluke Networks Model Number Belt clip lockable both ends P4080248 Belt clip non lockable both ends P4080249 Standard Line Co...

Страница 22: ...ories plus one last number redial memory Digit Capacity 23 digits per memory PBX Pause Duration User programmable default of 4 seconds Hook Flash Duration User programmable default of 600 ms Automatic...

Отзывы: