Physical Characteristics

The TONE/PULSE switch is on the inside of the hand 
grip near the receiver. This switch selects the dialing 
mode.

bfl02.eps

Figure 2. Controls and Indicators

Keypad

See Figure 3.

The TS30 Test Set keypad includes 12 standard dialing 
keys and 4 special purpose keys. All keys on the keypad 
are functional when the unit is in the Talk mode. They 
are not functional when the unit is in the Monitor 
mode.

bfl03.eps

Figure 3. Keypad

MUTE: Pressing the MUTE key shuts off the TS30 
transmitter for as long as the key remains depressed.

POLAR: When an off-hook unit is connected to a 
powered telephone line, pressing the POLAR key 
causes one of the LEDs to turn on. The LEDs indicate 
the polarity of direct current on the telephone line.

FLASH: Pressing the FLASH key will cause a timed 
interruption of the loop current. Some PBX setups or 
telephone office switches may use this signal to put a 
call on hold or to activate some special function.

REDIAL: This key allows the user to redial the last 
number dialed. 

Dialing Keys

See Figure 3.

When the TONE/PULSE switch is in the TONE position, 
each of the 12 dialing keys, when pressed, generate 
dialing tones. This includes the asterisk (

) and the 

pound (#) keys. When the TONE/PULSE switch is in the 
PULSE position, only the numeric keys (1, 2, 3, 4, 5, 6, 7, 
8, 9, 0) will cause pulses to be generated when pressed. 
In Pulse mode, the asterisk and pound keys are not 
functional. In Pulse mode the asterisk and pound keys 
will not be stored in the redial memory. 

The special purpose keys are labeled MUTEPOLAR
FLASH, and REDIAL.

Light Emitting Diodes (LEDs)

See Figure 3.

The LEDs are on each side of the keypad. One or the 
other of the LEDs will light only when the test set is in 
the Talk mode, connected to a powered telephone 
line, and the POLAR key is pressed. The LEDs indicate 
the polarity of current on the transmission line. See 
“Polarity Check”.

Содержание TS 30

Страница 1: ...TS 30 Test Set PN 2448469 October 2005 Rev 1 10 08 2005 2008 Fluke Corporation All rights reserved Printed in China All product names are trademarks of their respective companies Users Guide...

Страница 2: ...or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authori...

Страница 3: ...acteristics 2 Mode Controls 2 Keypad 3 Dialing Keys 3 Light Emitting Diodes LEDs 3 Line Cord 4 Operation 4 Line Monitoring 4 Dialing 4 Flash 4 Mixed Mode Dialing 4 Last Number Redial 5 Polarity Check...

Страница 4: ...TS30 Test Set Users Guide ii...

Страница 5: ...protection Impact resistant and rain resistant Field replaceable line cord Field replaceable spring loaded belt clip Ergonomic design Registration Registering your product with Fluke Networks gives y...

Страница 6: ...tasks The keypad has 16 keys that are recessed The recessed area protects the keypad and reduces accidental pressing of the keys The belt clip includes a spring loaded clip that ensures a secure conn...

Страница 7: ...setups or telephone office switches may use this signal to put a call on hold or to activate some special function REDIAL This key allows the user to redial the last number dialed Dialing Keys See Fig...

Страница 8: ...ive key is pressed If pulse signaling has been selected the desired number may be entered at any rate on the keypad The digits will automatically be pulsed out at the correct rate Move the TALK MONITO...

Страница 9: ...e loud enough in the receiver to make it difficult to hear the person on the other end of the telephone line Press and hold the MUTE key to shut off the transmitter thus eliminating the ambient noise...

Страница 10: ...h the replacement line cord To obtain a replacement line cord contact your local distributor or Fluke Networks Accessories To order accessories contact your local distributor or Fluke Networks Descrip...

Страница 11: ...n 600 ms 100 ms Ringer Loudness 70 dBA at 1 meter Ringer Equivalent REN 0 14 Physical Measurements 10 in x 2 83 in x 3 34 in 25 5 cm x 7 2 cm x 8 5 cm Weight 16 8 ounces 0 476 kg Environmental Tempera...

Страница 12: ...8 TS30 Test Set Users Guide...

Отзывы: