© 2018 The Snell Group / 322 N. Main St. / Suite 8 / Barre, VT 05641 / 800.636.9820 / www.thesnellgroup.com
7. SF
6
GAS MODE
From the home screen, depress the F2
button. Then using either the directional arrow buttons or the
touchscreen, select
SF
6
Gas Detection Mode
, then select
SF
6
Gas Detection Mode On
.
8. SF
6
HIGH GAIN or LOW GAIN:
For larger leaks under
ideal conditions you may select
Low Gain (Handheld)
Mode. For
small leaks or under less than ideal conditions tripod mount the
camera and select
High Gain (Tripod)
Mode.
9. SF
6
VIDEO or IMAGE CAPTURE MODE:
In SF
6
menu
select either
Image Capture
to set the recording mode to record
a single still image or
Video Capture
to set the recoding mode to
record a video sequence. See Paragraphs 10 and 11 to initiate
recording.
10. SINGLE IMAGE RECORDING:
When the camera has been set to Image Capture Mode, live images are paused
by depressing the green trigger once. Once an image has been paused, the options are given to
Save
,
Edit
or
Cancel
.
Selecting
Cancel
returns the imager to live operation. To save the image, either depress the F1 button or select
Save
on the touch screen. Select
Edit
to add an audio clip, a photo-note or change palette, or image fusion mode before
saving the image.
11. VIDEO IMAGE RECORDING:
When in SF
6
video image recording mode image recording is started depressing
the green trigger once to prepare to start recording (timer reads 00:00) and then a second time to actually start re
-
cording The timer will start advancing one second at a time. To stop or pause recording press the green trigger. Once
paused, the options are given to
Done
or
Cancel
. To continue recording press the green trigger. To save the recoding
press Done and then press
Save
. Selecting cancel will take you to a confirmation menu to
Cancel the recording and
Lose Video
.
12. RECALL A STILL IMAGE:
Depress the F2 button, and either using the directional buttons (< and >) or by interfac-
ing the touch screen, select
Memory
. In the Memory menu, use the directional buttons or touch screen to select an
image with an .
IS2
file extension , then either double-click on the image via the touchscreen or select OK to open the
selected image. Press F2
Back
to return to the memory Menu or F3
Cancel
to return live.
13. RECALL A VIDEO:
Depress the F2 button, and either using the directional buttons (< and >) or by interfacing the
touch screen, select
Memory
. In the Memory menu, use the directional buttons or touch screen to select an image
with an .
IS3
file extension , then either double-click on the image via the touchscreen or select OK to open the select-
ed image. A video sequence will be recalled and the video menu will appear. Press F2
Back
to return to the memory
Menu or F3
Cancel
to return live.
IFOV =1.31 mRad (Theoretical with 320 x 240 Detector and standard 24˚x17˚ lens)
IFOV =0.63 mRad (Theoretical with 320 x 240 Detector and standard 11.5˚x8.7˚ lens)
Detect 1in. target @ 64ft.
Detect 1in. target @ 132ft.
Ti-450 SF
6
with Standard Lens
Ti-450 SF
6
with Tele2 Lens
Quick
Start
FLUKE
Series Ti450 SF
6