Error Messages
When the Analyzer detects error conditions, the display shows
W
and an error code. See
. These error conditions disable or stop the test.
Tip: Push
INFO
for instructions about the error message.
Table 7. Error Codes
Error
Code
Test Type
Description
1.1
Pre-test
Automatic
Irregular voltage detected between inputs green and yellow
V
≥
50.0 V
1.2
Pre-test
Automatic
Irregular voltage detected between inputs red and blue
V
≥
1020 V, V
AB
Polarity: MINUS or AC (when V
≥
5.0 V)
1.3
Pre-test
Automatic
Irregular voltage detected between inputs blue and yellow
V
≥
30.0 V
1.4
Pre-test
Automatic
Short circuit current overload
I
SC
≥
20.5 A
1.5
Pre-test
Automatic
Irregular voltage detected between inputs red and green (or blue and
green)
V
≥
50.0 V
1.6
Pre-test
Automatic
Irregular voltage detected between inputs red and blue
V
≥
1020 V DC,
≥
720 V AC, MINUS (when V
≥
5.0 V)
1.7
Pre-test
Automatic
Irregular voltage detected between inputs green and yellow
V
≥
720.0 V
2.1
Automatic
Test
Overheating (over-temperature)
3.1
Automatic
Test
Memory overload
4.1
Test
Post-test
Fuse F1 Failed
Internal test indicates that the safety fuse (20 A) is open. F1 fuse
replacement must be done by a qualified technician.
4.2
Test
Post-test
Fuse F2 Failed
Internal test indicates that the safety fuse (0.63 A) is open and needs
to be replaced to do this measurement. See
.
4.3
Test
Post-test
Fuse F1 and F2 Failed
Internal test indicates that both safety fuses (20 A and 0.63 A) are
open and need to be replaced to do this measurement. F1 fuse
replacement must be done by a qualified technician.