LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and 

service. The warranty period is two years and begins on the date of shipment. Parts, product repairs, and services 

are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke 

authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, 

has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation 

or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications 

for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software 

will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but 

have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if 

product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. 

Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased 

in one country is submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or 

replacement of a defective product which is returned to a Fluke authorized service center within the warranty 

period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization 

information, then send the product to that service center, with a description of the difficulty, postage and insurance 

prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will 

be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was caused by 

neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling, including 

overvoltage failures caused by use outside the product’s specified rating, or normal wear and tear of mechanical 

components, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. 

Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the 

repair and return transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER 

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY 

SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF 

DATA, ARISING FROM ANY CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation 

of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every 

buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of 

competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.

LIMITED WARRANTY AND LIMITATION OF LIABILITY

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание PTi120

Страница 1: ...9 English 2019 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies www GlobalTestSupply com Find Qu...

Страница 2: ...nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB...

Страница 3: ...issivity Adjustment 11 Transmissivity 11 Memory Menu Memory Gallery 11 View Image 12 Notes 12 Notes with Single Image 12 Add a Note to Multiple Images 12 Delete Images 13 Delete an Image 13 Delete Mul...

Страница 4: ...nual ii Maintenance 16 Clean the Case 16 Lens Care 16 Battery Care 16 Charge Batteries 16 Radio Frequency Data 17 Specifications 17 www GlobalTestSupply com Find Quality Products Online at sales Globa...

Страница 5: ...Product shows thermal images on a high visibility industrial quality LCD touch screen The Product saves images to internal memory which can be transferred to a PC through a direct USB connection to th...

Страница 6: ...le Asset Identification Fullscreen IR Autoblend Fluke Connect desktop software Table 2 Controls and Connections Item Description Item Description LCD touch screen display G Hand strap Image capture bu...

Страница 7: ...iption Item Description Center point marker H Status bar Center point temperature I Background temperature Scale J Emissivity value D Temperature range upper value K Time E Range bar The range of colo...

Страница 8: ...en you move an imager between environments with large differences in ambient temperature allow for additional adjustment time Capture Image To capture an image 1 Focus on a target 2 Push and release t...

Страница 9: ...ggle switch Turns on or off a feature Feature on Radio button Selects one item from a list Option selected More menu options button Opens a menu to show other menu options Option menu button Opens an...

Страница 10: ...e Menu Palette options Set the palette to use on the image See Palette Menu D Display options Set the features to show on the display See Display Menu E Light Torch Use the toggle switch to turn on or...

Страница 11: ...some temperature overlays To adjust the IR Fusion level 1 Tap 2 Use the slider bar to set the IR Fusion level Alternatively you can adjust the IR Fusion level in camera mode Touch the display and sli...

Страница 12: ...u Use the Display menu to set which features to show on the display To show the Fluke logo on the display see Device Settings Menu Table 6 lists the options in the Display menu Table 6 Display Option...

Страница 13: ...infrared image radiometric temperature data visible image notes and tags into a single file To customize or separate the visible and infrared images use Fluke Connect desktop software Use to assign an...

Страница 14: ...n Source Software Licenses used to develop the Product Version NA Shows information about the version of the Product Table 9 IR Settings Menu Option Description Emissivity Select an emissivity value f...

Страница 15: ...ermine reliable and consistent actual temperatures The lower the emissivity is the greater the potential of error is when the Imager calculates the temperature measurement because more of the energy r...

Страница 16: ...ode 2 Tap If needed tap first If no notes are saved with the image a keyboard opens on the display 3 Use the keyboard to enter a message 4 Tap Save If a note is saved with the image a list of notes op...

Страница 17: ...The display returns to the memory gallery 2 Tap an image to select it Tap an image again to clear the selection The border and filename text color change to yellow 3 Repeat for each additional image 4...

Страница 18: ...lay 3 When the Product detects a barcode has been scanned tap Use Barcode or Use QR Code If the Product cannot detect a barcode or QR code manually enter a unique asset ID See Assign Asset ID Tag Manu...

Страница 19: ...cameras 1 On the website follow the instructions to download the software to the PC 2 On the PC follow the instructions to install Fluke Connect software Administrator privileges are required for the...

Страница 20: ...o remove excess liquid 4 Wipe the lens surface in one circular motion and discard the cloth 5 If needed repeat with a new lint free cloth Battery Care W Caution To prevent damage do not expose Product...

Страница 21: ...duct and the other end into a USB port on a PC 2 Charge until the charge indicator on the display does not flash 3 Disconnect the USB cable when the battery is fully charged W Caution To prevent damag...