2. INSTALLATION
Page 15
© 2011 Fluke Calibration
Table 7.
AMH-100 Mass Set Parts List
DESCRIPTION
PART NO.
Mass Set
Refer to Table 8
Reusable Molded Transit Case with Foam Inserts
40 kg set (MS-AMH-40)
60 kg set (MS-AMH-60)
80 kg set (MS-AMH-80)
100 kg set (MS-AMH-100)
3123990
1 ea.
1 ea.
1 ea.
1 ea.
3068984
1 ea.
2 ea.
2 ea.
3 ea.
Calibration Report
3152121
Table 8.
Mass Set Compositions
DESIGNATION
PART #
NOMINAL
TOTAL
MASS (kg)
MASS SET COMPOSITION
10
kg
5
kg
2
kg
1
kg
0.5
kg
0.2
kg
0.1
kg
MAKE-UP
MASS
(kg)
MS-7002-35
3069861
35
-
5
2
1
1
2
1
1 (4)
-
MS-7002-40
3070021
40
-
6
2
1
1
2
1
1 (4)
-
MS-7002-45
3069980
45
-
7
2
1
1
2
1
1 (4)
-
MS-7002-55
3069877
55
-
9
2
1
1
2
1
1 (4)
-
MS-7002-80
3070000
80
6
1
2
1
1
2
1
1 (9)
-
MS-7002-100
3070017
100
8
1
2
1
1
2
1
1 (9)
-
DESIGNATION
PART #
NOMINAL
TOTAL
MASS (kg)
MASS SET COMPOSITION
10
kg
6.4
kg
6.2
kg
3.2
kg
1.6
kg
0.8
kg
0.4
kg
0.2
kg
0.1
kg
BELL,
SHAFT,
BINARY
MASS
CARRIER
(3 PARTS)
MS-AMH-40
3071528
40
3
1
-
1
1
1
1
1
1
1
MS-AMH-60
3071519
60
5
1
-
1
1
1
1
1
1
1
MS-AMH-80
3071504
80
7
1
-
1
1
1
1
1
1
1
MS-AMH-100
3071440
100
9
1
-
1
1
1
1
1
1
1
All mass sets include a trim mass set of 50 g to 0.01 g (total 100 g)
Note
The mass loading bell and piston make up part of the total mass
load. The mass loading bell for loading manual mass sets is
ordered and shipped separately. The mass loading bell for AMH
mass sets is delivered with the mass set.
2.2
Site Requirements
The exact PG9000 system installation is affected by the elements other than the PG9000 Platform that
make up the PG9000 system.
When selecting and preparing a site to set up the PG9000 system, the following should be considered:
•
Ambient conditions:
To achieve optimum metrological performance, ambient conditions should be
controlled and maintained within the following:
♦
Temperature:
19 to 26 °C, minimize rate of change of temperature.
♦
Relative Humidity:
5 to 95 %RH (non-condensing).
♦
Ambient Pressure:
Minimize external influences that will cause barometric instability.
Содержание PG9000 Series
Страница 10: ...PG9602 OPERATION AND MAINTENANCE MANUAL 2011 Fluke Calibration Page X Notes...
Страница 128: ...PG9602 OPERATION AND MAINTENANCE MANUAL 2011 Fluke Calibration Page 118 Notes...
Страница 164: ...PG9602 OPERATION AND MAINTENANCE MANUAL 2011 Fluke Calibration Page 154 Notes...
Страница 188: ...PG9602 OPERATION AND MAINTENANCE MANUAL 2011 Fluke Calibration Page 178 Notes...
Страница 192: ...PG9602 OPERATION AND MAINTENANCE MANUAL 2011 Fluke Calibration Page 182 Notes...