M
ICRO
M
APPER
TM
ENGLISH - 5
M
ICRO
M
APPER
Tests
1. Slide the switch on the right side to the Cable
position to turn M
ICRO
M
APPER
on.
2. Connect one end of the cable to be tested to the
M
ICRO
M
APPER
's RJ45 jack.
3. Connect the other end of the cable to the M
ICRO
M
AP
-
PER
Remote's RJ45 jack.
4. Press
(TEST) to view the results.
5. The horizontal LEDs indicate the cable's integrity
status.
Green: Pair or Shield is good
Green flashing: Pair or Shield is faulty
No light: Pair is open or cable is not shielded
6. The vertical LEDs indicate the wiring faults and a low
battery status. Wiring faults are: SHORT, RE-
VERSED, MISWIRE, SPLIT PAIRS.
7. To find out a fault on a specific pair, use
M
ICRO
M
APPER
's diagnostic feature.
8. Press and hold
(TEST) for more than 2 seconds.
M
ICRO
M
APPER
will scan each pair and the shield
pausing and flashing each green LED separately. If a
faulty pair is detected, the corresponding fault status
will blink in red.
Note: Push the Remote Terminator onto the MicroMap-
per until it snaps into position. This configuration
allows you to conveniently test patch cables.