Using AutoTest, Switch, and Cable Test
23
ffy47.bmp
Figure 21. TruePower
TM
Enabled PoE AutoTest Results
ffy38.bmp
Figure 22. TruePower
TM
Enabled Poe Switch Results
Notice the switch was loaded down to 5v indicating it does
not support the selected Class.
Using the Reflector Feature (LR-AT 2000 only)
The Reflector feature allows the LR-AT 2000 to be used as a
remote device for Fluke Networks EtherScope Network
Assistant, MetroScope Service Provider, and the OptiView
Analyzer’s throughput performance tests.
See Reflector Configuration on page 14 for setting up this
feature. Once set up, the device can be used as the remote
responding device for throughput performance testing.
There is no start or stop, and no results are displayed on the
tester.
Using the Fiber Connection
Simply plug in the desired SFP adapter into the fiber port
on the top of the tester and connect the fiber cable to the
network. If both fiber and RJ-45 copper are connected to
the network, the copper connection has priority.
Figure 23 shows the Switch results through a fiber
connection with link, 1000 Mbps speed, full duplex, with a
signal strength of 7.35dBm.