background image

®

Model T100,

T120,
T140,

VDE 

Voltage/Continuity

Tester

Users Manual

November 2006

© 

2006 Fluke Corporation. All rights reserved. 

Printed in China

Содержание Fiber Viewer FT120

Страница 1: ...Model T100 T120 T140 VDE Voltage Continuity Tester Users Manual November 2006 2006 Fluke Corporation All rights reserved Printed in China...

Страница 2: ...In addition to category II the measuring circuit category III includes electric equipment subject to special demands with reference to safety and availability Examples House installations protective e...

Страница 3: ...trial applications as well as for household uses The voltage testers FLUKE T100 T120 T140 characterised by the following features Constructed in compliance with DIN EN 61243 3 DIN VDE 0682 Part 401 pr...

Страница 4: ...n cables or leaking batteries Prior to measurement ensure that the test leads and the test instrument are in per fect condition When using this instrument only the hand les of the probes may be touche...

Страница 5: ...ll the work the accident prevention regula tions of the commercial and industrial worker s compensation insurance carriers for electric in stallations and equipment must be heeded Appropriate Usage Th...

Страница 6: ...ity Polarity indication LCD for voltage display only FLUKE T120 and T140 Button on rear side for measurement point lightning Also resistance measure ment and RCD Trip Test in T140VDE Accessible electr...

Страница 7: ...ments are equipped with an internal load enabling the tripping of an RCD protection device of 10mA or 30mA For voltage tests L towards PE in sys tems with RCD devices the RCD may be triggered To avoid...

Страница 8: ...phase testing is not appro priate to determine whether a line is live or not For this purpose the double pole voltage test is always required The LED 5 is illuminated in the display Voltage Test with...

Страница 9: ...T Press Button on rear side for measurement point light 10 and read value on the display The resistance range is 1 1999 1 at a resolution of 1 1 The resistance test is active for 20 se conds after hav...

Страница 10: ...e and the rotary field direction are displayed signifies that the supposed phase L1 is the actual phase L1 and the supposed phase L2 is the actual phase L2 right rotary field signifies that the suppos...

Страница 11: ...d a mild household deter gent Never use acid detergents or dissolvents for cleaning After cleaning do not use the vol tage tester for a period of approx 5 hours Calibration Interval The voltage tester...

Страница 12: ...immediately If electrolyte got into your eye s rinse it them with water immediately and seek medical assistance Please consider your environment when you dispose of your one way batteries or accumula...

Страница 13: ...10 digits at 20 C Temperature coefficient 5 digits 10 K Test current 150 A Overvoltage protection 690V AC DC Continuity Test 0 400k1 Accuracy RN 50 Test current 5 A Overvoltage protection 690V AC DC...

Страница 14: ...uthorized service center to obtainreturn authorization information then send your defecti ve tester to that Service Center with adescription of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER W...