background image

C0-210 English Instruction Sheet

Page 

3

Establishing a Baseline

Before testing for CO, establish a baseline against which the
Probe compares other environments.

Do this by turning on the Probe. If the Probe detects between
0-3 PPM of CO, the beeper sounds, the LED flashes once a
second, and the Probe establishes a new baseline.

If the Probe detects more than 3 PPM, it does not establish a
new baseline, but starts taking CO measurements.

Automatic Power-Off

The Probe automatically turns itself off after 20 minutes.

Muting the Beeper

To mute the beeper, press the ON/OFF switch for more than 2
seconds when turning the instrument on.

To re-enable the beeper, turn the Probe off and then turn it back
on.

Using the Probe as a Stand-Alone Unit

When the Probe is used as a stand-alone indicator, the LED and
beeper indicate the presence of CO.

The faster the LED flashes and the beeper sounds, the higher
the concentration of CO.

Above 200 PPM the LED stays on, the beeper sounds
continuously, and the frequency of the tone increases with the
concentration of CO.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Содержание C0-210

Страница 1: ...s an accessory to a digital multimeter DMM that reads out 1 PPM as 1 mV dc The Probe is compatible with most DMMs that have an input impedance of 1 MΩ Contacting Fluke To contact Fluke call one of the following telephone numbers USA 1 888 99 FLUKE 1 888 993 5853 Canada 1 800 36 FLUKE 1 800 363 5853 Europe 31 402 675 200 Japan 81 3 3434 0181 Singapore 65 738 5655 Anywhere in the world 1 425 446 550...

Страница 2: ...ration exceeds 100 PPM 0 01 Turning the Probe On Install the battery To turn the Probe on press the green button The probe beeps twice then performs a 10 second self test during which the Probe emits a series of 2 beeps followed by a pause If the Probe passes the self test the Probe begins monitoring which is indicated by a beep every two seconds Self Test The Probe tests the sensor and the batter...

Страница 3: ...e automatically turns itself off after 20 minutes Muting the Beeper To mute the beeper press the ON OFF switch for more than 2 seconds when turning the instrument on To re enable the beeper turn the Probe off and then turn it back on Using the Probe as a Stand Alone Unit When the Probe is used as a stand alone indicator the LED and beeper indicate the presence of CO The faster the LED flashes and ...

Страница 4: ... of CO Above 1000 PPM the Probe outputs 5000 mV to indicate an over range condition 87 TRUE RMS MULTIMETER MIN MAX RANGE HOLD H Hz REL mA A V V OFF A COM V mA µA 1000V MAX 400mA MAX FUSED 10A MAX FUSED PEAK MIN MAX 41 2 DIGITS 1 Second µA CAT II III mV 6 1 2 4 3 5 mV mV DC QA001F EPS A Light Emitting Diode LED B ON OFF Button C Sensor Fluke PN 689497 D RJ45 Connector E Cable with RJ45 Connector an...

Страница 5: ...mmon Sources of CO Common sources of potentially dangerous levels of CO are Poorly maintained furnaces gas heaters or fireplaces Dirty or plugged chimneys or flue exhausts Poorly maintained gas oil or kerosene appliances Internal combustion engines e g automobiles lawnmowers blowers Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downloaded f...

Страница 6: ...ters Kerosene 1 Improper adjustment 2 Wrong fuel not K 1 3 Wrong wick or wick height 4 Not enough air to burn fuel 5 System not properly vented Water heaters Natural gas or LPG 1 Not enough air to burn fuel properly 2 Defective blocked flue 3 Maladjusted burner 4 Building not properly pressurized Ranges Ovens Natural gas or LPG 1 Not enough air to burn fuel 2 Maladjusted burner 3 Misuse as a room ...

Страница 7: ...hever is greater Sensor type Stabilized electrochemical Gas specific CO Typical sensor life 3 years Temperature Coefficient Add 0 4 per C 25 C Add 0 6 per C 20 C Output 1 mV dc 1 PPM carbon monoxide Self Test 20 seconds Battery 9 V NEDA 1604A or IEC 6LR61 or equivalent Typical battery life 500 hours Certification P Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com Downl...

Страница 8: ...ice during the warranty period send your defective tester to the nearest Fluke Authorized Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED FLUKE IS NOT LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES ARISING FROM ANY CAUSE OR THEORY Since some states...

Отзывы: