Supplement 

73 Series III Instruction Sheet 

 

 2 

8/04

 

Change #3 

On the first panel, under Safety Information, add the 
following: 

 

If this product is used in a manner not specified by the 
manufacturer, the protection provided by the 
equipment may be impaired. 

 

 

Before use, verify the meter’s operation by measuring 
a known voltage. 

 

 

Avoid working alone. 

 

 

Adhere to local and national safety codes. Individual 
protective equipment must be used to prevent shock 
and arc blast injury where hazardous live conductors 
are exposed. 

 

On the first panel, under Safety Information, replace the first 
bullet: 

 

From:   Never use the meter if the meter or test leads look 

damaged.  

 To: 

Do not use the meter if it is damaged. Before you 
use the meter, inspect the case. Look for cracks or 
missing plastic. Pay particular attention to the 
insulation surrounding the connectors. 
 

Inspect the test leads for damaged insulation or 
exposed metal. Check the test leads for continuity. 
Replace damaged test leads before you use the 
meter. 

On the first panel, prior to the Warning, add the following 
Caution:  

Caution 

To avoid possible damage to the meter 
or to the equipment under test, follow 
these guidelines: 
 