Safety 

A "

XW

 Warning" identifies conditions or actions that pose hazards to the user. 

A "

W

 Caution" identifies conditions and hazards that may damage the Calibrator 

or equipment under test. 

XW

 

Warnings 

To avoid electric shock, injury, or damage to the Calibrator: 

 

Use the Calibrator only as described in this Instruction Sheet.  

 

Using the Calibrator in a manner not specified by the manufacturer might 

impair the protection provided by the Calibrator. 

 

Do not use the Calibrator to make measurements in a CAT II, CAT III, or 
CAT IV environment. 
CAT I equipment is designed to protect against transient from high-
voltage, low-energy sources, such as electronic circuits or a copy 
machine. 

 

Do not use the Calibrator around explosive gas, vapor, or dust. 

 

Inspect the Calibrator before use. Do not use it if appears damaged. 

 

Check the test leads for continuity, damaged insulation, or exposed metal. 

Replace damaged test leads.  

 

Never apply more than 30 V between any two terminals, or between any 

terminal and earth ground. 

 

Use the proper terminals, mode, and range for your measuring or sourcing 

application. 

 

To prevent damage to the unit under test, put the Calibrator in the correct 

mode before connecting the test leads. 

 

When making connections, connect the COM test lead before the live lead; 

when disconnecting, disconnect the live lead before the COM lead.  

 

Never use the Calibrator with the case open. 

 

Make sure the battery door is closed before you use the Calibrator. 

 

Replace the battery as soon as the 

M

  (low battery) symbol appears to 

avoid false readings that can lead to electric shock. 

 

Remove test leads from the Calibrator before opening the case or battery 

door. 

 

To avoid a violent release of pressure in a pressurized system, shut off the 

valve and slowly bleed off the pressure before you attach or detach the 
pressure sensor or Pressure Module fitting to the pressure line. 

When servicing the Calibrator, use only specified replacement parts. 

 

W

 Caution  

When using pressure pressure modules, to avoid damage to the 
Calibrator module connections, follow all procedures in the pressure 
module instruction sheet.
 

W

 Caution 

When using pressure sensor connections, to avoid damage to the 
Calibrator or equipment to which it is attached: 

 

To avoid overpressure damage, do not apply pressures that exceed 
ranges listed under “Pressure Specifications”.  

Shop for Fluke products online at:

1.888.610.7664

www.

MyFlukeStore

.com

Содержание 717 1000G

Страница 1: ...ors hereafter the Calibrator include 717 1G 717 30G 717 100G 717 300G 717 500G 717 1000G 717 1500G 717 3000G 717 5000G Full Scale Pressure sensor is as listed in the Specifications section under Pressure Specifications The Calibrator is an IEC 61010 CAT I 30 V Pollution Degree 2 instrument A CAT I instrument is designed to protect against transients from low energy sources like for example electro...

Страница 2: ...atibility Table 1 Pressure Unit and Range Compatibility Units Range Units Range psi All kPa All inH2O Through 3000 psi inHg All cmH2O Through 1000 psi mmHg Through 3000 psi bar 15 psi and above kg cm 2 15 psi and above mbar Through 1000 psi Symbols Symbol Meaning ON OFF button J Earth ground W Caution Important information See instruction sheet X Hazardous voltage risk of electric shock f Pressure...

Страница 3: ...damage to the unit under test put the Calibrator in the correct mode before connecting the test leads When making connections connect the COM test lead before the live lead when disconnecting disconnect the live lead before the COM lead Never use the Calibrator with the case open Make sure the battery door is closed before you use the Calibrator Replace the battery as soon as the M low battery sym...

Страница 4: ...essure Press U to select a different unit When you turn the Calibrator OFF the next time you turn the Calibrator back ON it returns to the pressure unit you last used The lower part of the display shows the current up to 24 mA applied to the current mA inputs See Figure 2 Power Saver The Calibrator automatically turns off after 30 minutes of inactivity To reduce this time or disable this feature 1...

Страница 5: ...ALIBRATOR Current mA measurement Pressure measurement Pressure module input Pressure sensor input Current input On Off Button a I 69 mPa RANGE 83 TO 690 kPa 12 TO 100 PSI MAX 200 PSI 1 4 mP qo005f eps Figure 2 The Pressure Calibrator 717 100G is Shown Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 6: ...the display The gsymbol appears on the display Press h again to resume normal operation In ZERO mode press to decrease barometric pressure Switch Test To perform a switch test do the following Note This example uses a normally closed switch The procedure is the same for an open switch but the display reads OPEN instead of CLOSE 1 Connect the Calibrator mA and COM terminals to the switch using the ...

Страница 7: ...s 1 bar 750 mmHg 1 mmHg 0 0013332 bar 1 psi 2 036 inHg 1 inHg 0 49115 psi Sourcing Loop Voltage To use the Calibrator to supply loop power 24 V dc to a current transmitter that is disconnected from the system 1 With power off hold down Uwhile pressing OON The LOOP POWER icon appears on the display 2 With the transmitter disconnected from normal loop power connect the Calibrator in series with the ...

Страница 8: ...n and exit Calibrating a P I Transmitter To calibrate a P I pressure to current transmitter 1 Open the pump vent and zero the Calibrator before applying pressure Repeat frequently to ensure accuracy 2 Apply a pressure to the transmitter and measure the transmitter s current loop output OL overload is displayed at full scale 3 Connect the Calibrator to the transmitter as shown in Figure 4 or Figure...

Страница 9: ...OM mA 30V MAX 100psi 689kPa RANGE MAX LOOP POWER BAROMETRIC ADJ 717 100G PRESSURE CALIBRATOR S I G N A L T E S T Red Black I 69 T T SWITCH TEST mA MODE MIN MAX ENTER qo002f eps Figure 4 Connecting to an Internal Pressure Sensor Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 10: ...COM mA 30V MAX 100psi 689kPa RANGE LOOP POWER BAROMETRIC ADJ 717 100G PRESSURE CALIBRATOR MIN MAX mA MODE SWITCH TEST a I 69 mPa RANGE 83 TO 690 kPa 12 TO 100 PSI MAX 200 PSI 1 4 mP ENTER qo006f eps Figure 5 Connecting to a Pressure Module Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 11: ...eturned for a fixed fee Cleaning Periodically wipe the case with a damp cloth and detergent do not use abrasives or solvents Calibration Calibrate your Calibrator yearly to ensure that it performs to specification A Calibration Manual Fluke PN 686540 is available Replacing the Battery XW Warning To avoid false readings which could lead to electric shock or injury replace the battery as soon as M l...

Страница 12: ...it07f eps Figure 6 Battery Installation Shop for Fluke products online at 1 888 610 7664 www MyFlukeStore com ...

Страница 13: ...7 1 B 717 300G Top Case Decal 2547021 1 B 717 500G Top Case Decal 2547039 1 B 717 1000G Top Case Decal 2547042 1 B 717 1500G Top Case Decal 2547056 1 B 717 3000G Top Case Decal 2547063 1 B 717 5000G Top Case Decal 2547074 1 C Keypad 2113087 1 D Spacer for pressure input 687449 1 E O ring for pressure input 146688 1 F 9 V battery ANSI NEDA 1604A or IEC LR61 614487 1 G Case bottom 2397526 1 Figure 7...

Страница 14: ...acement Parts and Accessories cont Specifications Accuracy is specified for 1 year after calibration at operating temperatures of 10 C to 55 C Pressure Specifications Model Range SI Range Metric Max SI Max Metric 717 1G 1 to 1 PSI 7 to 7 kPa 5 PSI 34 5 kPa 717 30G 12 to 30 PSI 83 to 207 kPa 60 PSI 413 kPa 717 100G 12 to 100 PSI 83 to 690 kPa 200 PSI 1379 kPa or 1 4 mPa 717 300G 12 to 300 PSI 83 to...

Страница 15: ...tion Accuracy of Reading Counts 24 mA 0 001 mA 0 015 2 Overload protection Fuseless overvoltage protection Temperature coefficient 0 005 of range per C for temperature ranges of between 10 C to 18 C and 28 C to 55 C Loop Supply 24 V dc nominal General Specifications Maximum voltage applied between either an mA terminal and earth ground or between the mA terminals 30 V Storage temperature 40 C to 6...

Страница 16: ...Europe B V P O Box 9090 P O Box 1186 Everett WA 98206 9090 5602 BD Eindhoven U S A The Netherlands Limited Warranty Limitation Of Liability This Fluke product will be free from defects in material and workmanship for 3 years from the date of purchase This warranty does not cover fuses disposable batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of ope...

Отзывы: