background image

For the most complete temperature documentation 

solution, predictive maintenance professionals use 

the Fluke 576 photographic infrared thermometer. In 

addition to all the features found in the 574 precision 

IR thermometer, including advanced extra bright 

coaxial three-dot laser sighting system; 100-point 

data logging; customizable log names; programmable 

emissivity values; and monitoring, analysis, and 

reporting software, the Fluke 576 also integrates a 

digital camera for photographic documentation.

Fluke 576 photo documentation

Simultaneously measure temperature and digitally 

photograph the target and its surroundings. A wealth of 

data is instantly captured in a digital photo: time 

and date stamp, temperature data and location 

name. Photos and data are easily downloaded 

into the accompanying PC software. The addition 

of the photos helps to enhance reports, to more 

explicitly communicate problem areas with repair 

personnel, and to ensure consistency when taking 

repeated measurements over time when looking 

for equipment condition trends.

Fluke 576

Model 

Fluke 576

Temperature Range 

-30 to 900 ºC (–25 to 1600 ºF)

D:S (Distance to spot size) at 90 % energy 

60:1 (50:1 with Close Focus option)

Laser sighting 

3-dot, coaxial

Emissivity  

Adjustable

Accuracy 

± 0.75 % of reading or ± 0.75 ºC (± 1.5 ºF)

(Assumes ambient operating temperature of 23 ºC [73 ºF]) 

(whichever is greater over the balance of the range) 

 

Response time 

250 mSec

Display hold (7 seconds)  

LCD backlit 

MAX, MIN, DIF, AVG temperatures 

HI/LO alarm 

Bar graph display 

100-points data logging 

Maximum number of 640 x 480 pixel photos (VGA) 

26

Maximum number of 320 x 240 pixel photos (VGA) 

100

Data graphing & photo viewing software 

(Windows XP and 2000 compatible) USB required 

Image fi le format 

.jpg fi les

Protective hard case 

Weight and dimensions 

580 g (1 lb 4 oz) and 16.7 x 5 x 23.8 cm (6.58 x 1.97 x 9.57 in)

Power  

2 AA Batteries / USB

Battery life (alkaline) 

8 hours (13 hours with photographic mode off) 

 

50 photos w/fl ash; 200 photos without fl ash

Warranty 

2 years, conditional

Содержание 572

Страница 1: ...name in test tools You will find all the information you need in this brochure to order and promote the newest non contact infrared thermometers from Fluke Industrial infrared thermometers for every application 62 Mini 576 574 572 66 63 68 ...

Страница 2: ...ictive maintenance program Fluke has the right tool for the job even when the job requires measuring the temperature of very hot very cold hard to reach moving distant or dangerous objects And Fluke backs its tools with the industry s best warranty and highest rated customer service When professional technicians need industrial IR thermometers they come to the number one name in test tools Profess...

Страница 3: ...ng detect changes along a wide or continuous target region Key markets Predictive and preventive maintenance Electrical and mechanical equipment monitoring HVAC R Residential and commercial troubleshooting Process monitoring Product quality assurance Construction Building inspections Petrochemical applications and hazardous locations Mechanically thermally or chemically hostile environments ...

Страница 4: ...38 mm 6 x 4 x 1 5 in Power 9 V alkaline or NiCD battery Battery life alkaline 12 hours Display hold 7 seconds LCD backlit Warranty 2 years conditional Fluke 62 Mini For quick basic temperature checks in applications where the technician is close to the target there s nothing simpler than using a Fluke 62 Mini just aim the laser sighting at the center of your target pull the trigger and read the te...

Страница 5: ...in 0 60 lb Included with the 62 Mini IR thermometer The Fluke 62 Mini IR thermometer includes a 9 V alkaline battery illustrated user s guide protective boot and convenient storage pouch Ordering information To order Fluke products please fax purchase orders to 1 425 446 5844 Call 1 800 757 5747 for questions on orders Order status inquiry is available on the Fluke Partner Portal Please refer to t...

Страница 6: ...760 ºC 25 to 999 ºF 25 to 1100 ºF 20 to 1400 ºF D S Distance to spot size 12 1 30 1 50 1 at 90 energy Laser sighting Single point offset Emissivity Preset 0 95 Adjustable Accuracy Assumes ambient 1 of reading or 1 ºC 2 ºF whichever is greater over the balance of the range operating temperature of 23 ºC 73 ºF Response time 500 mSec MAX MIN DIF and AVG temperatures MAX only All Recall last reading H...

Страница 7: ...glish English Price Fluke 63 2148281 0 95969 26114 2 Infrared 25 4 cm 10 in 19 1 cm 7 5 in 6 9 cm 2 75 in 0 9370 kg China 209 Thermometer 2 06555 lb Fluke 66 2148296 0 95969 26115 9 Adjustable 25 4 cm 10 in 19 1 cm 7 5 in 6 9 cm 2 75 in 0 9370 kg China 389 Infrared 2 06555 lb Thermometer Fluke 68 2148308 0 95969 26116 6 Adjustable 25 4 cm 10 in 19 1 cm 7 5 in 6 9 cm 2 75 in 0 9370 kg China 499 Inf...

Страница 8: ... log location names programmable emissivity settings and PC software for condition monitoring and process control Model Fluke 572 Fluke 574 Fluke 574 NI Temperature Range 30 to 900 ºC 25 to 1600 ºF D S Distance to spot size 60 1 50 1 with close focus option close focus not available with NI model at 90 energy Laser sighting extra bright 3 dot coaxial twice as bright as perceived by the human eye w...

Страница 9: ...ailable on the Fluke Partner Portal Please refer to the instructions on the back panel to register for access to the Partner Portal Included with the 572 and 574 IR thermometers 572 and 574 IR thermometers include 2 AA batteries user s manual and a durable hard case The 574 also includes AC power supply thermocouple K RS 232 cable and condition monitoring software Options Nonincendive 574 Intended...

Страница 10: ...areas with repair personnel and to ensure consistency when taking repeated measurements over time when looking for equipment condition trends Fluke 576 Model Fluke 576 Temperature Range 30 to 900 ºC 25 to 1600 ºF D S Distance to spot size at 90 energy 60 1 50 1 with Close Focus option Laser sighting 3 dot coaxial Emissivity Adjustable Accuracy 0 75 of reading or 0 75 ºC 1 5 ºF Assumes ambient oper...

Страница 11: ... in 7 in 2 3 in 36 lb AN5 24327178 0 95969 29170 5 Cable Analog Output 2 5 cm 1 5 m 14 cm 055 kg Germany 50 98 in 5 ft 5 5 in 121 lb Included with every 576 IR thermometer The 576 infrared thermometer includes 2 AA batteries a durable hard case operator s guide on CD thermocouple K probe software and USB computer cable Software for condition monitoring and process control Scan thumbnails of measur...

Страница 12: ...eet Fluke 572 574 2437646 and 574 NI Product Data Sheet Fluke 576 2437668 Product Data Sheet Infrared 2437125 Thermometry Q and A Fluke Corporation PO Box 9090 Everett WA 98206 9090 USA Download digital files and information to support these products from the Fluke Partner Portal including Product data sheets Press releases Photos Order status inquiry If you have not already registered for access t...

Отзывы: