LIMITED WARRANTY AND LIMITATION OF LIABILITY 

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and 

service. The warranty period is two years and begins on the date of shipment. Parts, product repairs, and 

services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of 

a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in 

Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal 

conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with 

its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke 

does not warrant that software will be error free or operate without interruption. 

Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers 

only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is 

available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the 

applicable international price. Fluke reserves the right to invoice Buyer for importation costs of 

repair/replacement parts when product purchased in one country is submitted for repair in another country. 

Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, 

or replacement of a defective product which is returned to a Fluke authorized service center within the 

warranty period. 

To obtain warranty service, contact your nearest Fluke authorized service center to obtain return 

authorization information, then send the product to that service center, with a description of the difficulty, 

postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following 

warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke 

determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal 

condition of operation or handling, including overvoltage failures caused by use outside the product’s 

specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair 

costs and obtain authorization before commencing the work. Following repair, the product will be returned to 

the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges 

(FOB Shipping Point). 

THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER 

WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY 

OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE 

FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, 

INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. 

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or 

limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not 

apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other 

decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other 

provision. 

Fluke Corporation

P.O. Box 9090 

Everett, WA  98206-9090 

U.S.A. 

Fluke Europe B.V.

P.O. Box 1186 

5602 BD Eindhoven 

The Netherlands 

 

 

 

11/99 

 
 
 
 
 
 
 
 
 
 
 

Shop for Fluke products online at:

1.877.766.5412

www.

MyFlukeStore

.com

Содержание 572-2

Страница 1: ...l March 2013 2013 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies Shop for Fluke products online at 1 877 766 5412 www MyFlukeStore com ...

Страница 2: ...center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB Destination Fluke assumes no risk for damage in transit Following warranty repair the product will be returned to Buyer transportation prepaid FOB Destination If Fluke determines that failure was caused by neglect misuse contamination...

Страница 3: ...ght 9 Time Date 9 Delete Data 10 Delete All Data 10 Delete Individual Data Records 10 How the Product Works 11 Product Operation 11 Temperature Measurement 11 Locate a Hot or Cold Spot 12 Distance and Spot Size 12 Field of View 13 Emissivity 13 HOLD 13 Data Storage 14 Data Download 14 External Contact Probe 15 Troubleshooting 15 Maintenance 16 Battery Charge 16 Battery Replacement 16 Shop for Fluk...

Страница 4: ...se 17 User Replaceable Parts and Accessories 17 User Replaceable Parts 17 Accessories 18 Recommended Temperature Probes 18 Specifications 19 K Type Thermocouple Probe Specifications 20 Shop for Fluke products online at 1 877 766 5412 www MyFlukeStore com ...

Страница 5: ...e Page 1 Symbols 3 2 Top Level Menu Description 5 3 Nominal Surface Emissivity 7 4 Troubleshooting 15 5 Replaceable Parts 17 6 Recommended Temperature Probes 18 Shop for Fluke products online at 1 877 766 5412 www MyFlukeStore com ...

Страница 6: ...572 2 Users Manual iv Shop for Fluke products online at 1 877 766 5412 www MyFlukeStore com ...

Страница 7: ... Menu Navigation 5 3 How the Product Works 11 4 Locating a Hot or Cold Spot 12 5 Distance and Spot Size 12 6 Field of View 13 7 Thermocouple and USB Connections 14 8 Battery Replacement 17 Shop for Fluke products online at 1 877 766 5412 www MyFlukeStore com ...

Страница 8: ...572 2 Users Manual vi Shop for Fluke products online at 1 877 766 5412 www MyFlukeStore com ...

Страница 9: ...l one of the following telephone numbers Technical Support USA 1 800 44 FLUKE 1 800 443 5853 Calibration Repair USA 1 888 99 FLUKE 1 888 993 5853 Canada 1 800 36 FLUKE 1 800 363 5853 Europe 31 402 675 200 Japan 81 03 6714 3114 Singapore 65 738 5566 Anywhere in the world 1 425 446 5500 Or visit Fluke s website at www fluke com To register your product visit http register fluke com To see print or d...

Страница 10: ...rs telescopes microscopes Optical tools can focus the laser and be dangerous to the eye Do not look into the laser Do not point laser directly at persons or animals or indirectly off reflective surfaces Use the product only as specified or hazardous laser radiation exposure can occur Do not use laser viewing glasses as laser protection glasses Laser viewing glasses are used only for better visibil...

Страница 11: ...ual Warning Laser Conforms to European Union directives C Celsius F Fahrenheit Battery This product complies with the WEEE Directive 2002 96 EC marking requirements The affixed label indicates that you must not discard this electrical electronic product in domestic household waste Product Category With reference to the equipment types in the WEEE Directive Annex I this product is classed as catego...

Страница 12: ... Standard miniature K type thermocouple connector input Printed 572 2 Getting Started 572 2 Manuals CD 12 or 24 hour clock Last reading Hold 20 seconds Multi language interface High and low temperature alarm Data storage and review Trigger lock USB 2 0 computer interface cable FlukeView Forms Documenting Software Display The Product display can show data in these languages English Spanish French G...

Страница 13: ...enter Softkey Right Softkey Description 1 Save Save reading to memory Menu Light Adjust backlight brightness 2 Mem Review delete memory entries Menu Set emissivity 3 MnMx Enables Min Max Menu Avg Enable Avg Diff 4 C F Toggle between C and F Menu Alarm Set and enable alarms 5 Lock Lock the Product on Menu Laser Toggle the laser on off 6 Setup Turn off on backlight Change Time Date Change Language M...

Страница 14: ...ght softkey The backlight can be disabled using the Setup menu See Setup for more information Memory The Product can store measurement records including time date emissivity and measurement record numbers see Save for more information The Product can store 99 records To access records stored in memory 1 Push the Menu softkey until Mem shows as the left softkey function 2 Push the Mem softkey to ac...

Страница 15: ...e softkey when finished to return to the main menu Table 3 Nominal Surface Emissivity Material Value Material Value Default 0 95 Glass plate 0 85 Aluminum 0 30 Iron 0 70 Asbestos 0 95 Lead 0 50 Asphalt 0 95 Oil 0 94 Brass 0 50 Paint 0 93 Ceramic 0 95 Plastic 0 95 Concrete 0 95 Rubber 0 95 Copper 0 60 Sand 0 90 Food Frozen 0 90 Steel 0 80 Food Hot 0 93 Water 0 93 Wood 0 94 Oxidized Opaque over 20 m...

Страница 16: ...ange and white To set either the high or low alarm 1 Push the Menu softkey until Alarm shows as the right softkey function 2 Push the Alarm softkey to access the Alarm menu 3 Push either the Hi or Lo softkey depending on which alarm will be set 4 Push the ON softkey to turn the alarm on 5 Push the OFF softkey to turn the alarm off 6 Use the Set softkey to access the Hi or Lo Alarm Set menu 7 Use t...

Страница 17: ...ways on Use this menu to change the backlight setting from on to off Turn the backlight off to conserve battery power 1 Push the Menu softkey until Setup shows as the left softkey function 2 Push the Setup softkey 3 Backlight has an indicator next to it To enter the backlight menu push the Enter softkey 4 Push the OFF softkey to turn the backlight off push the ON softkey to turn it on 5 Push the B...

Страница 18: ... Push the Next softkey to move through each parameter 11 Push the Done softkey when finished The display reverts to the start of the Time Date menu Delete Data To delete stored data from the Product from the main menu push the menu softkey until Mem shows as the left softkey function The last memory location shows on the display To access the Delete menu push the Delete softkey From here all of th...

Страница 19: ...n Temperature Measurement To measure temperature point the Product at an object and pull the trigger You can use the laser pointer to aim the Product You can also insert the K type thermocouple probe for contact measurement Be sure to consider distance to spot size ratio and field of view see Distance and Spot Size and Field of View The temperature is shown on the display Note The laser is used fo...

Страница 20: ... Size As the distance D from the object being measured increases the spot size S of the area measured by the Product becomes larger The relationship between distance and spot size D S for each Product is shown in Figure 5 The spot sizes indicate 90 encircled energy D S 60 1 D S 20 77 mm 500 mm 82 19 69 19 17 mm 1150 mm 75 45 28 31 70 mm 1500 mm 1 25 59 05 21 38 mm 250 mm 84 9 84 hdp05 eps Figure 5...

Страница 21: ...he surface beneath it Measure the temperature of the tape or painted surface If you cannot paint or use tape then you can improve the accuracy of your measurements by either numerically adjusting emissivity or by using the Emissivity Menu to access a table of some common materials The Product has numerically adjustable emissivity from 0 10 to 1 00 that can be used in conjunction with the emissivit...

Страница 22: ... USB cable and the included FlukeView Forms Documenting Software See the FlukeView Forms documentation for details The USB input is located on the top of the Product next to the external probe input see Figure 7 Note To prevent incorrect readings do not do a temperature measurement of an earthed conductor while the Product is connected to a PC that is earthed by a three phase grounding plug 1 2 hd...

Страница 23: ... Product Table 4 Troubleshooting Symptom Cause Action on display Target temperature is over or under range Select target within specifications Low batteries Replace batteries Blank display Thermometer is asleep Possible dead batteries Pull trigger Replace batteries Laser does not work Low or dead batteries Ambient temperature is above 40 C 104 F Replace batteries Use in area with lower ambient tem...

Страница 24: ...operation and maintenance of the Product Repair the Product before use if the batteries leak Be sure that the battery polarity is correct to prevent battery leakage Caution Do not short the battery terminals together Do not keep cells or batteries in a container where the terminals can be shorted Do not put battery cells and battery packs near heat or fire Do not put in sunlight Note The batteries...

Страница 25: ... or soft cloth Caution To avoid damaging the Product do NOT submerge it in water Do not use abrasive cleaners they will damage the case User Replaceable Parts and Accessories User Replaceable Parts See Table 5 for a list of replaceable parts Table 5 Replaceable Parts Part Part Number 572 2 Manuals CD 4307031 572 2 Getting Started English French German Spanish Portuguese Russian 4307046 Shop for Fl...

Страница 26: ...r tracking continuously changing temperature differentials on hydronic tubing and pipe loops and good for quick accurate refrigerant temperatures 80PK 9 The insulation piercing probe provides a sharp tip to pierce pipe insulation and flat probe tip for good surface thermal contact air temperatures within ducts and vent temperatures 80PK 11 Flexible cuff thermocouple temperature probe is a convenie...

Страница 27: ...C 0 1 F Optical Distance Spot 90 energy 60 1 calculated at 90 energy Laser sighting Offset dual laser output 1 mW Minimum spot size 19 mm Operational Emissivity Digitally adjustable from 0 10 to 1 00 by 0 01 or via built in table of common materials see Table 3 for list of materials and value Probe input KTC Should display simultaneous probe and IR temperature Data storage 99 points Communication ...

Страница 28: ...500 F Accuracy 1 1 C 2 0 F from 0 C to 260 C 32 F to 500 F Typically within 1 1 C 2 0 F from 40 C to 0 C 40 F to 32 F Cable Length 1 m 40 in K type thermocouple cable with standard miniature thermocouple connector and bead termination Shop for Fluke products online at 1 877 766 5412 www MyFlukeStore com ...