Getting Started 

ArbExplorer Feature Highlights

 

 

396

 - Three powerful tools in one software package: complete Instrument control 

panel, Waveform composer and FM signal composer 

 

397

 - Four powerful tools in one software package: complete Instrument control 

panel, Waveform, pulse, and FM signal composer 

 

397

 - Detailed virtual front panels control all of the Instrument’s functions and 

modes 

 

Wave composer generates, edits and downloads complex waveforms 

 

FM wave composer generates and downloads complex modulating signals 

 

397

 - Easy, onscreen generation of complex pulses using the pulse composer. 

 

396

 - Automatic detection of active instruments  

 

Equation editor generates waveforms from equations 

 

SCPI command and response editor simulates ATE operation 

 

Translates waveform coordinates from ASCII and other formats 

 

Simplifies generation of complex sequences

 

Features, Functions, and Options 

The following is a general description of the features, functions, and options available 

with the Instrument. 

Output Channels 

The 396 is a single channel arbitrary waveform generator.  
The 397 is a dual-channel waveform generator. Although the two channels share a single 

sample clock source, each channel can be controlled separately to generate different 

waveform, amplitude and waveforms sequence. Having a single sample clock source is 

an advantage in a dual-channel configuration because it allows tight control over inter-

channel synchronization and leading edge start phase where the initial skew between the 

two channels is just a few nanoseconds.  

Output Functions 

The Instrument is completely digital. There are no analog functions resident in its 

hardware circuits. Data has to be downloaded to the Instrument for it to start generating 

waveforms. The Instrument can generate a few standard functions such as sine wave, 

triangular wave and square wave. Each time that a standard function is required, the 

Instrument calculates its coordinates and places them in the waveform memory. 

Therefore, every time a standard function is selected, minimal time is required for the 

controller to compute the function and load its data to the waveform memory. 

Frequency 

Waveform frequency is programmed with 7 digits on the 396 and 9 digits on the 397. 

Frequency accuracy of the output waveform is determined by the clock reference. The 

internal reference oscillator provides 1 ppm accuracy and stability over time and 

temperature. If higher accuracy and/or stability are required, you may connect an external 

frequency reference to the rear-panel reference input connector. 

Содержание 396

Страница 1: ...396 397 Waveform Generators Getting Started PN 2340639 January 2005 2005 Fluke Corporation All rights reserved Printed in USA All product names are trademarks of their respective companies ...

Страница 2: ...rvice center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB Destination Fluke assumes no risk for damage in transit Following warranty repair the product will be returned to Buyer transportation prepaid FOB Destination If Fluke determines that failure was caused by neglect misuse contami...

Страница 3: ...tor is used for controlling the Instrument and generating editing and downloading waveforms from a remote computer The following highlights the Instrument and the ArbExplorer features Feature Highlights 397 Dual output configuration with independent waveform control 397 Tight phase offset control between channels 1 point resolution 14 bit vertical resolution Nearly 19 bit offset resolution 396 1 M...

Страница 4: ...e each channel can be controlled separately to generate different waveform amplitude and waveforms sequence Having a single sample clock source is an advantage in a dual channel configuration because it allows tight control over inter channel synchronization and leading edge start phase where the initial skew between the two channels is just a few nanoseconds Output Functions The Instrument is com...

Страница 5: ...ge from 8192 to 8191 14 bits Using a high speed clocking circuit the digital contents of the arbitrary waveform memory are extracted and routed to the Digital to Analog Converter DAC The DAC converts the digital data to an analog signal and the output amplifier completes the task by amplifying or attenuating the signal at the output connector Memory Segmentation There is no need to use the complet...

Страница 6: ...trol There is no limit to the number of units that can be daisy chained multiple unit synchronization is built into each Instrument Safety Considerations The Instrument has been manufactured according to international safety standards The Instrument meets EN61010 VDE 0411 03 81 and UL 1244 standards for safety of commercial electronic measuring and test equipment for instruments with an exposed me...

Страница 7: ...The correct fuse to use is Littelfuse Cat No 218500 T 250VAC 0 5A All other devices connected to or in proximity to this instrument are properly grounded or connected to the protective third wire earth ground Supplied Accessories The Instrument is supplied with this Getting Started Manual a disk containing the Getting Started Manual and the Users Manual and a disk containing a Windows version of t...

Страница 8: ...396 397 Getting Started 6 ...

Отзывы: