Fluke 393 FC Скачать руководство пользователя страница 4

 

4    Fluke Corporation     Solar Tools Kit with 393 FC Clamp Meter, Irradiance Meter and Solar Test Leads

https://www.fluke.com/en-us/product/electrical-testing/clamp-meters/solar-tools-393-irrsol

Voltage Frequency

 

 

 

Range

5.0 Hz to 500.0 Hz

 

 

Resolution

0.1 Hz

 

 

Accuracy

0.5 % RD + 5 digits

 

 

Trigger Level

5 Hz to 20 Hz, ≥5 V

 

 

 

20 Hz to 100 Hz, ≥5 V

 

 

 

100 Hz to 500 Hz, ≥10 V

 

 

DC Power

 

 

 

Range

600.0 kVA (600.0 V dc range)

 

 

 

1500 kVA (1500 V dc range)

 

 

Resolution

0.1 kVA

 

 

 

1 kVA

 

 

Accuracy

2 % RD + 2.0 kVA

 

 

 

2 % RD + 20 kVA

 

 

Resistance

 

 

 

Range

600.0 Ω

 

 

 

6000 Ω

 

 

 

60.00 kΩ

 

 

Resolution

0.1 Ω (≤600.0 Ω)

 

 

 

1 Ω (≤6000 Ω)

 

 

 

0.01 kΩ (≤60.00 kΩ)

 

 

Accuracy

1 % RD + 5 digits

 

 

Capacitance

 

 

 

Range

100.0 μF

 

 

 

1000 μF

 

 

Resolution

0.1 μF (≤100.0 μF)

 

 

 

1 μF (≤1000 μF)

 

 

Accuracy

1 % RD + 5 digits

 

 

Inrush Trigger Level

5 A

 

 

Mechanical

 

 

 

Size (L x W x H)

281 mm x 84 mm x 49 mm

 

 

Weight (with batteries)

520 g

 

 

Jaw Opening

34 mm

 

 

Flexible Current Probe Diameter

7.5 mm

 

 

Flexible Current Probe Cable Length

 

 

 

(head to electronics connector)

1.8 m

 

 

Environmental

 

 

 

Operating Temperature

-10 °C to 50 °C

 

 

Storage Temperature

-40 °C to 60 °C

 

 

Operating Humidity

Non condensing (<10°C)

 

 

 

≤90 % RH (at 10 °C to 30 °C)

 

 

 

≤75 % RH (at 30 °C to 40 °C)

 

 

 

≤45 % RH (at 40 °C to 50 °C)

 

 

Operating Altitude

2000 m

 

 

Storage Altitude

12 000 m

 

 

Ingress Protection (IP) Rating

IEC 60529: IP54 non-operating

 

 

Electromagnetic Compatibility (EMC)

 

 

 

Содержание 393 FC

Страница 1: ...lex is an industrial clamp meter designed for solar photovoltaic PV installation technicians and maintenance professionals who work in high voltage dc environments Safely connect the MC4 test leads to...

Страница 2: ...rminal and Earth Ground AC 1000 V DC 1500 V Batteries 2 AA IEC LR6 alkaline Display Dual display with backlight Automatic Power Off 20 minutes Electrical Accuracy Accuracy is specified for 1 year afte...

Страница 3: ...nt Range 999 9 A Resolution 0 1 A Accuracy 2 RD 5 digits 1 1 When using the ZERO B function to compensate for offsets AC Voltage Range 600 0 V 1000 V Resolution 0 1 V 600 0 V 1 V 1000 V Accuracy 1 RD...

Страница 4: ...ution 0 1 600 0 1 6000 0 01 k 60 00 k Accuracy 1 RD 5 digits Capacitance Range 100 0 F 1000 F Resolution 0 1 F 100 0 F 1 F 1000 F Accuracy 1 RD 5 digits Inrush Trigger Level 5 A Mechanical Size L x W...

Страница 5: ...tice of it This equipment is intended for use in business environments and not to be used in homes USA FCC 47 CFR 15 subpart B This product is considered an exempt device per clause 15 103 Safety Gene...

Страница 6: ...tic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes There may be potential difficulties in ensuring electromagnetic compatibility...

Страница 7: ...r Test Leads https www fluke com en us product electrical testing clamp meters solar tools 393 irrsol Contact Brass Nickel Plated Brass Nickel Plated Length 60 36 12 Voltage CAT III 1000V CAT III 1000...

Страница 8: ...1500 V TRMS clamp meter Test leads CAT III 1500 V rated right angle plugs with safety caps iFlex 18 inch flexible current probe TPAK magnetic hanging strap Premium carrying case 3 year warranty FLK IR...

Страница 9: ...425 446 5500 www fluke com 2022 Fluke Corporation Specifications subject to change without notice 12 2022 Modification of this document is not permitted without written permission from Fluke Corporat...

Отзывы: