3014-PR English Instruction Sheet 

Page 

 

Environmental Specifications 

Operating Temperature 

14 ° to 131 °F (-10 ° to +55 °C) 

Storage Temperature 

-40 ° to 158 °F (-40 ° to +70 °C) 

 Altitude 

Non-operating: 0 to 12,000 m  

Operating: 0 to 2000 m 

Operating Relative 

Humidity 

 

10 to 35 °C 85 % RH  

(without roll-off above 35 °C) 

Influence of Temperature 

 

150 ppm/°K, or 0.15 % of mV output per 

10 °K 

Influence of Humidity  

(10 to 90% RH) 

 

0.2 % of mV output per 10 °K @ 18 °C to 

28 °C 

Safety Specifications 

Electrical 

  

Conforms to EN/IEC 61010 and 61010-2-

032 

600 V Cat. III, Pollution Degree 2 

Electromagnetic 

Compatibility 

  

EN 50081-1 Class B  

EN 50082-2 Electrostatic discharge; IEC 

61000-4-2  

Radiated field IEC 61000-4-3  

Fast transients IEC 61000-4-4  

Magnetic field at 50/60 Hz IEC 61000-4-8 

Содержание 3014-PR

Страница 1: ...s the latest safety and performance standards Symbols The table below lists the symbols used on the Clamp and or in this instruction sheet Symbol Description Do not dispose of this product as unsorted municipal waste Go to Fluke s website for recycling information W Risk of Danger Important Information See manual X Hazardous Voltage Risk of electric shock T Double insulation Application around and...

Страница 2: ...the operating instructions otherwise the safety features may not protect you Adhere to local and national safety codes Individual protective equipment must be used to prevent the shock and arc blast injury where hazardous live conductors are exposed Before each use inspect the Clamp Look for cracks or missing portions of the housing or output cable insulation Also look for loose or weakened compon...

Страница 3: ...Clean the Clamp periodically by wiping it with a damp cloth and detergent Do not use abrasive cleaners or solvents Do not immerse the Clamp in liquids Specifications Electrical Specifications Operating Range 40 A Measurement Range 0 1 to 40 A Transformation Ratio Voltage output Output Signal 50 mV A 2 V 40 A Range Accuracy Phase Shift 0 1 to 1 A 2 of Reading 1 mV 1 to 5 A 1 of Reading 1 mV 3 5 to ...

Страница 4: ...t 50 60 Hz Influence of Frequency 40 Hz to 1 kHz 0 5 of mV output 1 kHz to 10 kHz 2 of mV output Mechanical Specifications Dimensions 5 47 x 2 00 x 1 18 in 139 x 51 x 30 mm Weight 180 g 6 5 oz Jaw Opening 0 83 in 21 mm Maximum Conductor Size Cable Bus Bar 0 78 in 20 mm 0 78 x 0 19 in 20 x 5 mm Case Protection IP 40 IEC 60529 Drop Test 1 0 m six sides to oak floor Vibration MIL PRF 28800F Polycarbo...

Страница 5: ...hout roll off above 35 C Influence of Temperature 150 ppm K or 0 15 of mV output per 10 K Influence of Humidity 10 to 90 RH 0 2 of mV output per 10 K 18 C to 28 C Safety Specifications Electrical Conforms to EN IEC 61010 and 61010 2 032 600 V Cat III Pollution Degree 2 Electromagnetic Compatibility EN 50081 1 Class B EN 50082 2 Electrostatic discharge IEC 61000 4 2 Radiated field IEC 61000 4 3 Fas...

Страница 6: ... operation or handling Resellers are not authorized to extend any other warranty on Fluke s behalf To obtain service during the warranty period contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTI...

Отзывы: