3000 FC 

Wireless Multimeter 

Users Manual 

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 

Содержание 3000 FC

Страница 1: ... reserved Specifications are subject to change without notice All product names are trademarks of their respective companies 3000 FC Wireless Multimeter Users Manual Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Страница 2: ...the warranty period contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSED OR IMPLIED FLUKE IS NOT LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR L...

Страница 3: ...ty Information 1 Hazardous Voltage 5 Test Lead Alert 5 Battery Saver Sleep Mode 5 Wireless Radio 5 MIN MAX AVG Record Mode 6 Display Hold 7 Yellow Button 7 Display Backlight 7 Manual and Auto Range 8 Power Up Options 8 Features 9 AC Zero Input Behavior of True rms Meters 13 ...

Страница 4: ...ements 20 Capacitance Measurements 21 Continuity Test 22 AC or DC Current Measurements 23 Diode Test 25 Frequency Measurement 27 Maintenance 29 General Maintenance 29 Fuse Test 29 Battery and Fuse Replacement 30 Service and Parts 33 Specifications 36 AC Voltage 38 DC Voltage Continuity Resistance Diode Test and Capacitance 39 AC and DC Current 40 Frequency 40 Frequency Counter Sensitivity 41 Input...

Страница 5: ...e Product The 3000 FC Wireless Multimeter the Product is a True rms Digital Multimeter Safety Information The Product complies with ANSI ISA 82 02 01 CAN CSA C22 2 No 61010 1 12 3rd Edition UL 61010 1 3 rd Edition IEC EN 61010 1 2010 Measurement Category III 1000V Pollution Degree 2 Measurement Category IV 600V Pollution Degree 2 ...

Страница 6: ...fied measurement category voltage or amperage ratings Do not use the Product around explosive gas vapor or in damp or wet environments Do not touch voltages 30 V ac rms 42 V ac peak or 60 V dc Do not exceed the Measurement Category CAT rating of the lowest rated individual component of a Product probe or accessory Measure a known voltage first to make sure that the Product operates correctly Do no...

Страница 7: ...urement category CAT voltage and amperage rated probes test leads and adapters for the measurement Do not use test leads if they are damaged Examine the test leads for damaged insulation exposed metal or if the wear indicator shows Check test lead continuity Keep fingers behind the finger guards on the probes Do not touch the probes to a voltage source when the test leads are connected to the curr...

Страница 8: ...nd similar points of the low voltage MAINS installation Measurement Category III is applicable to test and measuring circuits connected to the distribution part of the building s low voltage MAINS installation Measurement Category IV is applicable to test and measuring circuits connected at the source of the building s low voltage MAINS installation This product complies with the WEEE Directive ma...

Страница 9: ...isplay Wireless Radio The Product uses low power 802 15 4 wireless radio technology to send or receive measurements to other wireless test tools or the Fluke Connect app on a mobile device such as a smartphone or tablet You can set up to pair with A mobile device Use the Fluke Connect app to view measurements remotely save to Fluke Cloud storage and share the information with your team Up to three...

Страница 10: ...ect measurement function and on the correct range Autorange is disabled while in a MIN MAX AVG record session 2 Push and Max show at the top of the display The measurement in the display is the maximum value measured It changes only when a new maximum value is sensed 3 To pause MIN MAX AVG record push shows on the display while record is paused Recorded values are not deleted To continue the recor...

Страница 11: ...asurements continue to update To hold a measurement on the display push The display shows when display hold is turned on Push again to stop hold mode and show measurements on the display Yellow Button Push the yellow button to set the Product to a different measurement function The different functions are shown in yellow around the rotary switch Frequency mV ac capacitance diode test and mA dc are...

Страница 12: ... range push Note You cannot change range when the Product is in the MIN MAX AVG record mode or in display hold mode If you push in one of these modes the Product beeps twice to alert you to an invalid operation Power Up Options To set a power up option hold down the button shown in Table 2 while you turn on the Product Table 2 Power Up Options Button Power Up Option Turns off the beeper yellow Tur...

Страница 13: ...Product features with descriptions Table 3 Inputs 3 1 2 gxr001 eps Terminal Description mA Input for 3 00 mA to 400 0 mA current measurements and current frequency COM Return terminal for all measurements Input for voltage resistance diode capacitance and voltage frequency ...

Страница 14: ...sure ac voltage from 6 mV to 600 mV 1 Resistance measurements from 0 1 Ω to 50 MΩ Push to measure capacitance from 1 nF to 9999 μF Continuity Beeper turns on at 25 Ω and turns off at 250 Ω Push for diode test Shows OL above 2 0 V AC current measurements from 3 00 mA to 400 mA Push to measure dc current from 3 00 mA to 400 mA 1 Push again to measure frequency from 2 Hz to 9 99 kHz 1 This function s...

Страница 15: ...cts frequency Selects ac millivolts 1 Selects capacitance Selects diode test Push once to select dc milliamps Push twice to select ac frequency 1 All positions Sets the Product to manual range and scrolls through each range Push for 1 second to set the Product to autorange All positions Freezes the display ...

Страница 16: ...position Moves the highlight on the display to the next radio mode or wireless test tool shown in the display Hold for 1 second to pair all selected test tools to the Product and stop the discovery procedure 2 Not related to switch position Turns on the radio and shows the radio mode selection screen shows on the display when the radio is on In App mode sends the measurement to the Fluke Connect A...

Страница 17: ...ange Unspecified input levels on the lowest ranges are AC voltage less than 1 of 600 mV ac or 6 mV ac AC current less than 5 of 60 mA ac or 3 mA ac Wireless Radio Setup The Product uses wireless radio technology to send or receive measurements to other wireless test tools or the Fluke Connect app The range of the radio is up to 20 m 66 ft The term discovery in this manual refers to a procedure the...

Страница 18: ... 1 Go to Settings Bluetooth Verify that Bluetooth is turned on 2 Go to the Fluke Connect app and in the list of connected Fluke tools select 3000 FC On the Product the display updates to show the ID 1 through 10 App ID 1 24 14 VDC Auto Pair with Wireless Test Tools When the radio is set to the Tools receive mode the Product can discover up to 6 test tools and then pair with up to 3 wireless test t...

Страница 19: ... to show Tools and a series of dots to indicate that discovery is in progress Tools 24 16 VDC Auto Note If no radio signals are discovered after 2 minutes the radio in the Product turns off When the discovery procedure is complete the icon shows on the display display updates to show a list of test tools with the ID number and the model name arrow icon on the display indicates a scrollable list fo...

Страница 20: ... the selection mode 3 Repeat steps 1 and 2 to select up to 3 test tools Note To pair with a test tool after the discovery procedure has completed turn off the radio Turn on the radio to restart the discovery procedure When in the Tool receive mode display updates to show the live measurement of the selected test tool up to 3 the button blinks at 4 to 5 second intervals on the Product and each sele...

Страница 21: ...r personal injury disconnect power and discharge all high voltage capacitors before you measure resistance continuity capacitance or a diode junction The figures that follow show how to make basic measurements with the Product When you connect the test leads to the circuit or device connect the common COM test lead before the live lead When you remove the test leads remove the live lead before the...

Страница 22: ...3000 FC Users Manual 18 Volts AC Volts DC Millivolts DC gxr002 eps Figure 1 AC and DC Voltage Measurements ...

Страница 23: ...io When the Product is set to the Volts Hz function the voltage range is set to manual If the voltage increases to a value larger than the range the Product shows OL in the display If the voltage drops to less than 5 of the range the value shown in the display can be invalid Set the Product as shown in Figure 2 to measure volts Hz Volts Hz Volt Hz x 2 gxr011 eps Figure 2 Volt Hertz Ratio ...

Страница 24: ... diode junction The Product sends a small current through the circuit for resistance measurements Because the current flows through all possible paths between the probes the resistance measured is the total resistance of all paths between the probes The resistance ranges are 600 0 Ω 6 000 kΩ 60 00 kΩ 600 0 kΩ 6 000 MΩ and 50 00 MΩ Set the Product as shown in Figure 3 to measure resistance gxr003 e...

Страница 25: ...r personal injury disconnect power and discharge all high voltage capacitors before you measure resistance continuity capacitance or a diode junction Capacitance ranges are 1 000 nF 10 00 μF 100 0 μF and 9999 μF To measure capacitance set up the Product as shown in Figure 4 gxr004 eps Figure 4 Capacitance Measurements ...

Страница 26: ...ltage capacitors before you measure resistance continuity capacitance or a diode junction The continuity test uses a beeper that sounds when a closed circuit is sensed The beeper lets you do continuity tests without the necessity to look at the display To do a continuity test set up the Product as shown in Figure 5 gxr005 eps Figure 5 Continuity Tests ...

Страница 27: ...possible damage to the Product or the equipment under test Do a fuse test before current measurements See Fuse Test Use the correct terminals function and range for all measurements Do not put the probes across in parallel with a circuit or component when the test leads are connected to the current terminals Turn off circuit power break the circuit put the Product in series and then turn on circui...

Страница 28: ...3000 FC Users Manual 24 DC gxr007 eps Figure 6 AC and DC Current Measurements ...

Страница 29: ...e junction A good silicon junction drops between 0 5 V and 0 8 V To do a diode test on a diode out of circuit set up the Product as shown in Figure 7 For forward bias measurements on a semiconductor component put the red test lead on the positive terminal of the component and put the black test lead on the negative terminal of the component In a circuit a good diode has a forward bias measurement ...

Страница 30: ...3000 FC Users Manual 26 Good Diode Bad Diode Bad Diode Good Diode Reverse Bias 1 BEEP OPEN and Shorted Forward Bias gxr006 eps Figure 7 Diode Test ...

Страница 31: ...rement shows 0 Hz or is not stable the input signal can be below or near a trigger level A lower range increases the sensitivity of the Product and can usually repair these problems An input signal with distortion can cause a frequency measurement to be higher than usual The distortion can cause the frequency counter to sense multiple triggers A higher voltage range decreases the input sensitivity...

Страница 32: ...3000 FC Users Manual 28 Hz x 2 Hz AC DC Voltage Frequency AC Current Frequency gxr008 eps Figure 8 Frequency Measurement ...

Страница 33: ... the Product and remove all test leads 2 Shake out dirt that can possibly be in the terminals 3 Soak a clean swab with weak detergent and water 4 Move the swab around in each terminal 5 Dry each terminal with canned air to push the water and detergent out of the terminals Warning To prevent electrical shock or personal injury remove the test leads and all input signals before you replace the batte...

Страница 34: ...fied replacement fuses Remove the batteries if the Product is not used for an extended period of time or if stored in temperatures above 50 C If the batteries are not removed battery leakage can damage the Product Repair the Product before use if the battery leaks Be sure that the battery polarity is correct to prevent battery leakage Batteries contain hazardous chemicals that can cause burns or e...

Страница 35: ...w ones Use the correct battery orientation 6 Install the battery door 7 Turn the battery door latch until the locked symbol aligns with the arrow To replace the fuse 1 Turn off the Product and remove all test leads 2 As shown in Figure 10 remove six screws from the case bottom 3 Pull the case bottom from the case top 4 Remove the fuse from its holder and replace it with a 440 mA 1000 V FAST fuse w...

Страница 36: ...3000 FC Users Manual 32 gxr010 eps Figure 10 Battery and Fuse Replacement ...

Страница 37: ...How to Contact Fluke section Table 6 Replaceable Parts Description Qty Fluke Part or Model Number Fuse 440 mA 1000 V 1 943121 Battery AA 1 5 V 3 376756 Battery Door Assembly includes tilt stand 1 4207624 Gasket Battery Door 1 4137532 Test Lead Set 1 TL175 Alligator Clip Black 1 AC175 Alligator Clip Red 1 3000 FC DMM Quick Reference Guide 1 4231002 3000 FC DMM Safety Information 1 4231677 To ensure...

Страница 38: ...s Manual 34 Battery AA x 1 5 V Battery Door TL175 Test Lead Set AC175 Threaded Alligator Clips 3000 FC Quick Reference Guide 3000 FC Safety Information Fuse 440 mA 1000 V Fast gxr012 eps Figure 11 Replacement Parts ...

Страница 39: ...Measures from 4 mA dc to 20 mA dc FLK A3004 FC a3004 FC Wireless DC Clamp Measures from 10 A dc to 2000 A dc FLK T3000 FC t3000 FC Wireless K Type Thermometer Measures temperature with a k type thermocouple from 200 C to 1372 C FLK V3000 FC v3000 FC Wireless AC Voltage Measures ac voltage to 1000 V ac FLK V3001 FC v3001 FC Wireless DC Voltage Measures dc voltage to 1000 V dc FLK PC3000 FC pc3000 F...

Страница 40: ... 1000 counts Battery Type Three AA Alkaline batteries NEDA 15A IEC LR6 Battery Life 250 hours minimum Temperature Operating 10 C to 50 C Storage 40 C to 60 C Relative Humidity 0 to 90 0 C to 35 C 0 to 75 35 C to 40 C 0 to 45 40 C to 50 C Altitude Operating 2000 m Storage 12 000 m Temperature Coefficient 0 1 X specified accuracy C 18 C or 28 C Wireless Frequency 2 4 GHz ISM Band 20 meter range Size...

Страница 41: ...tic purposes There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances Caution This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments Emissions that exceed the levels required by CISPR 11 can occur when the equipment is con...

Страница 42: ...significant digits AC Voltage Range 1 Resolution Accuracy 2 3 4 45 Hz to 500 Hz 500 Hz to 1 kHz 600 0 mV 0 1 mV 1 0 3 2 0 3 6 000 V 0 001 V 60 00 V 0 01 V 600 0 V 0 1 V 1000 V 1 V 1 All ac voltage ranges are specified from 1 of range to 100 of range 2 Crest factor of 3 at 4000 counts decreasing linearly to 1 5 at full scale 3 For non sinusoidal waveforms add 2 of reading 2 full scale typical for c...

Страница 43: ...00 V 1 V 0 15 2 600 Ω 1 Ω Meter beeps at 25 Ω beeper detects opens or shorts of 250 μs or longer Ω 600 0 Ω 0 1 Ω 0 5 2 6 000 kΩ 0 001 kΩ 0 5 1 60 00 kΩ 0 01 kΩ 600 00 kΩ 0 1 kΩ 6 000 MΩ 0 001 MΩ 50 00 MΩ 0 01 MΩ 1 5 3 Diode Test 2 000 V 0 001 V 1 2 1000 nF 1 nF 1 2 2 10 00 μF 0 01 μF 100 0 μF 0 1 μF 9999 μF 1 1 μF 10 typical 1 In the 9999 μF range for measurements to 1000 μF the measurement accura...

Страница 44: ... 0 1 mA 1 All ac current ranges are specified from 5 of range to 100 of range 2 Input burden voltage typical 400 mA input 2 mV mA 3 400 0 mA accuracy specified up to 600 mA overload Frequency Range Resolution Accuracy 1 99 99 Hz 0 01 Hz 0 1 1 999 9 Hz 0 1 Hz 9 999 kHz 0 001 kHz 99 99 kHz 0 01 kHz 1 Frequency is specified up to 99 99 kHz in volts and up to 10 kHz in amps ...

Страница 45: ...00 V 500 V 300 V 320 V 380 V NA 6 V 0 5 V 0 75 V 1 4 V 4 0 V Unspecified 3 60 V 4 V 3 8 V 4 3 V 6 6 V 13 V 600 V 40 V 36 V 39 V 45 V 58 V 1000 V 500 V 300 V 320 V 380 V NA 60 00 mA 5 mA 4 mA NA NA NA 400 0 mA 5 mA 4 mA NA NA NA 1 Maximum input for specified accuracy 10X Range or 1000 V 2 Noise at low frequency and amplitude may exceed the frequency accuracy specification 3 Unspecified but usable d...

Страница 46: ...Hz Open Circuit Test Voltage Full Scale Voltage Typical Short Circuit Current To 6 MΩ 50 MΩ Ω 1100 V rms 2 7 V dc 0 7 V dc 0 9 V dc 350 μA 1100 V rms 2 7 V dc 2 000 V dc 1 1 mA Function Overload Protection Overload mA Fused 44 100 A 1000 V FAST Fuse 600 mA overload for 2 minutes maximum 10 minutes rest minimum MIN MAX Recording Function Accuracy DC Functions The specified accuracy of the measureme...