background image

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The 

warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 

days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not 

apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, 

contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will 

operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on 

non-defective media. Fluke does not warrant that software will be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no 

authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is 

purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the 

right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted 

for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or 

replacement of a defective product which is returned to a Fluke authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, 

then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB 

Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, 

transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination, 

alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused by use outside 

the product’s specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair 

costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer 

transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, 

EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR 

FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, 

INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY 

CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of 

incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any 

provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such 

holding will not affect the validity or enforceability of any other provision.

Fluke Corporation
P.O. Box 9090
Everett, WA  98206-9090
U.S.A.

11/99

Содержание 1630-2

Страница 1: ...0 2017 2020 Fluke Corporation All rights reserved All product names are trademarks of their respective companies Specifications are subject to change without notice 1630 2 1630 2 FC Earth Ground Clamp...

Страница 2: ...n warranty service contact your nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty pos...

Страница 3: ...eral Specifications 5 Ground Loop Resistance 5 AC Leakage Current mA 5 Operational Error for Ground Resistance Measurement 6 Equipment and Environment 7 Setup 7 Performance Verification 8 Calibration...

Страница 4: ...ii 1630 2 1630 2 FC Calibration Manual...

Страница 5: ...hat measures the ground resistance without auxiliary ground rods and AC leakage current The Clamp is used in multi grounded systems without disconnecting the ground under test For complete operating i...

Страница 6: ...re exposed Use Product approved measurement category CAT voltage and amperage rated accessories probes test leads and adapters for all measurements Do not use the Product if it is altered or damaged D...

Страница 7: ...China metrology certification mark for measuring instruments manufactured in the People s Republic of China PRC Measurement Category III is applicable to test and measuring circuits connected to the...

Страница 8: ...esistance to Earth IEC 61557 5 Effectiveness of the Protective Measures IEC 61557 16 cutoff frequency 20 kHz 3 dB Electromagnetic Compatibility EMC International IEC 61326 1 Portable Electromagnetic E...

Страница 9: ...050 1 000 to 9 999 1 5 0 100 10 00 to 49 99 1 5 0 30 50 00 to 99 99 1 5 0 50 100 0 to 199 9 3 0 1 0 200 0 to 399 9 5 0 5 0 400 to 599 10 0 10 600 to 1500 20 00 1 Loop resistance with no inductance con...

Страница 10: ...arameter Specification Typical Max 1 Intrinsic uncertainty IEC 61557 13 A Reference conditions 0 06 0 20 Conductor Position IEC 61557 13 E1 30 0 06 0 20 Battery Voltage IEC 61557 13 E2 4 4 V to 6 4 V...

Страница 11: ...Table 3 for a list of requirements for the verification tests and calibration adjustment Table 3 Equipment Requirements CAL Point Accuracy Unit Minimum Required Characteristics IET 1433 20 0 100 1 5...

Страница 12: ...surement of the loop to include in the applied resistance Table 4 Performance Test Points for Resistance Function Test Point Applied Resistance Display Reading Value Unit Lower Limit Upper Limit OHM 0...

Страница 13: ...p during self calibration 3 Push and hold N 2 s to turn on the Clamp The meter will enter self calibration mode when power on Self calibration mode ends in 5 seconds After self calibration the meter e...

Страница 14: ...ep apply the input signal according to the indication on the lower portion of the screen Table 6 is a list of the calibration points 8 calibration points for ac leakage current verification and adjust...

Страница 15: ...urrent loop See Figure 1 The calibrator output value should be half of the value shown on the screen For example the calibrator output should be 0 100 mA for the calibration point shown on the screen...

Страница 16: ...he jaw with the precision decade resistance box an a 1 loop short copper wire See Figure 2 The applied resistance value should be the same on the calibrator as the value on the screen below Figure 2 C...

Страница 17: ...ation Procedure 13 4 When calibration signal is ready push E to confirm the current calibration point As the system calibrates H shows on the the screen When H symbol turns off the next calibration po...

Страница 18: ...00 0 100 mA 60 HZ 3 CAL 03 0 400 0 200 4 CAL 04 4 000 2 000 5 CAL 05 40 00 20 00 6 CAL 06 400 200 0 7 CAL 07 4000 2000 8 CAL 08 40 00 A AC 20 00 A 9 CAL 09 10 CAL 10 0 100 0 100 11 CAL 11 0 250 0 250...

Страница 19: ...sives Battery Replacement XW Warning To prevent false readings that could lead to possible electric shock or personal injury replace the batteries as soon as the low battery indicator appears To repla...

Страница 20: ...T Battery Primary Zn Mn02 1 5 V 2 24 ah Alkaline AA 376756 U Battery Door Assembly 4779851 V Dual Battery Contact 4386306 W Contact Battery Cathode 4304552 X Contact Battery Anode 4304565 Y Foam Pad...

Страница 21: ...Earth Ground Clamp Maintenance 17 Figure 3 Replacement Parts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33...

Страница 22: ...1630 2 1630 2 FC Calibration Manual 18...

Отзывы: