Table 1-1. Specifications
Maximum Voltage
Between any Terminal
and Earth Ground
600V ms
Display
3 3/4-digits, 4000 counts, updates 4/sec
Operating Temperature
-10
°
C to 50
°
C
Storage Temperature
-30
°
C to 60
°
C indefinitly (to -40
°
C for 100 hrs)
Temperature Coefficient
0.1 x (specified accuracy)/
°
C (<18
°
C or >28
°
C)
Relative Humidity
0% to 90% (-10
°
C to 35
°
C) 0% to 70% (35
°
C to 50
°
C)
Battery Type
9V, NEDA 1604 or IEC 6F22
Battery Life
650 continious hours with alkaline 450 continious hours with carbon-zinc
Shock, Vibration
1 meter shock. Per MIL-T-28800D for a Class 3 Instrument
Size (HxWxL)
1.35 in x 2.75 in x 5.55 in (3.46 cm x 7.05 cm x 14.23 cm)
Weight
10 oz (286 g)
Safety
Designed to Protection Class II requirement of UL1244, ANSI/ISA-S82,
CSA C22.2 No 231, and VDE 0411, and IEC 1010 overvoltage category
III.
EMI Regulations
Complies with FCC Part 15, Class B, and VDE 0871B.
Accuracy (50 to 400 Hz)
Function
Range
Resolution
Model 10
Models 11/12
Volts AC
4000 mV*
1 mV
±(2.9%+3)
±(1.9%+3)
4.000V
0.001V
±(2.9%+3)
±(1.9%+3)
40.00V
0.01V
±(2.9%+3)
±(1.9%+3)
400.0V
0.1V
±(2.9%+3)
±(1.9%+3)
600V
1V
±(2.9%+3)
±(1.9%+3)
Volts DC
4000 mV
1 mV
±(1.5%+2)
±(0.9%+2)
4.000V
0.001V
±(1.5%+2)
±(0.9%+2)
40.00V
0.01V
±(1.5%+1)
±(0.9%+1)
400.0V
0.1V
±(1.5%+1)
±(0.9%+1)
600V
1V
±(1.5%+1)
±(0.9%+1)
Resistance
400.0
Ω
0.1
Ω
±(1.5%+2)
±(0.9%+2)
4.000 k
Ω
0.001 k
Ω
±(1.5%+1)
±(0.9%+1)
40.00 k
Ω
0.01 k
Ω
±(1.5%+1)
±(0.9%+1)
400.0 k
Ω
0.1 k
Ω
±(1.5%+1)
±(0.9%+1)
4.000 M
Ω
0.001 M
Ω
±(1.5%+1)
±(0.9%+1)
40.00 M
Ω
0.01 M
Ω
±(1.9%+3)
±(1.5%+3)
Capacitance
1.000
µ
F
0.001
µ
F
NA
±(1.9%+2)
10.00
µ
F
0.01
µ
F
NA
±(1.9%+2)
100.0
µ
F
0.1
µ
F
NA
±(1.9%+2)
1000
µ
F
1
µ
F
NA
±(1.9%+2)
10000
µ
F
10
µ
F
NA
±(10%+90) Typical
Continuity/Diode
Test
2.000V
0.001V
±(1.5%+2)
±(0.9%+2)
* The 4000 mV range can only be entered in the manual range mode. Use the 4000 mV range with
accessories.
** The beeper is guaranteed to come on at <25
Ω
and turn off at >250
Ω
. The meter detects opens or shorts
of 250
µ
s or longer.
Содержание 12
Страница 2: ......
Страница 6: ......
Страница 8: ......
Страница 10: ......
Страница 11: ......
Страница 12: ...1 1 Chapter 1 Introduction and Specifications Title Page 1 1 Introduction 1 3 1 2 Specifications 1 3 ...
Страница 13: ......
Страница 18: ...10 11 12 Multimeters Service Manual 2 2 ...
Страница 25: ...10 11 12 Multimeters Service Manual 3 2 ...
Страница 35: ...10 11 12 Multimeters Service Manual 4 2 ...
Страница 43: ...10 11 12 Multimeters Service Manual 4 10 ana07f eps Figure 4 3 Fluke 10 Schematic ...
Страница 45: ...10 11 12 Multimeters Service Manual 4 12 ana09f eps Figure 4 4 Fluke 11 Schematic ...
Страница 47: ...10 11 12 Multimeters Service Manual 4 14 ana11f eps Figure 4 5 Fluke 12 Schematic ...
Страница 49: ...10 11 12 Multimeters Service Manual 4 16 FEDERAL SUPPLY CODES FOR MANUFACTURES ...
Страница 50: ...Replaceable Parts and Schematics Warranty and Service Centers 4 4 17 SERVICE CENTERS ...
Страница 51: ...10 11 12 Multimeters Service Manual 4 18 SERVICE CENTERS CONT ...