Reference Pressure Gauge 

 

Error Codes 

15 

ftH2O60F 

Pressure in feet of water at 60 °F 

iNHg0C 

Pressure in inches of mercury at 
0 °C  

mmHg0C 

Pressure in millimeters of mercury 
at 0 °C  

kpal 

Pressure in kilopascals 

Far 

Temperature in Fahrenheit 

Cel 

Temperature in Celsius 

mSW 

Pressure in meters of SeaWater 

ftSW 

Pressure in feet of SeaWater 

MPA 

Pressure in MegaPascal 

torr 

Pressure in Torr (mmHG0C) 

Error Codes 

The gauge uses the subsequent error codes: 

101 

A non-numeric entry was received 
where it should be a numeric entry 

102 

Too many significant digits entered 

103 

Invalid units or parameter value 
received 

105 

Entry is above the upper limit of 
the allowable range 

106 

Entry is below the lower limit of the 
allowable range 

108 

A required command parameter 
was missing 

109 

An invalid pressure unit was 
received 

117 

An unknown command was 
received 

120 

The serial input buffer overflowed 

121 

Too many entries in the command 
line 

122 

Pressure module not connected

1.888.610.7664 

[email protected]

Fluke-Direct

.com

Содержание 095969376969

Страница 1: ...rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies 2700G Series Reference Pressure Gauge Users Manual 1 888 610 7664 sa...

Страница 2: ...r replacement of a defective product which is returned to a Fluke authorized service center within the warranty period uke assumes no risk for damage in transit Following warranty repair the product w...

Страница 3: ...pment 2 Safety Information 2 Special Conditions for Safe Use 3 Symbols 4 Display and Buttons 5 Operation 6 How to Setup the Product 6 Engineering Units 6 Set Auto Off 7 Show Battery Voltage 7 Display...

Страница 4: ...roduct 9 How to Change the Batteries 10 Accessories 11 USB Interface Cable 11 Power Module 11 Serial Interface Instructions 13 Initiating Communication 13 List of Commands 13 Parameter Units 14 Error...

Страница 5: ...iii List of Tables Table Title Page 1 Symbols 4 2 Display and Buttons 5 3 Units Conversion 16 1 888 610 7664 sales GlobalTestSupply com Fluke Direct com...

Страница 6: ...v List of Figures Figure Title Page 1 The Product 5 2 Change the Batteries 10 3 USB Power Module and Universal Connectors 12 1 888 610 7664 sales GlobalTestSupply com Fluke Direct com...

Страница 7: ...or in applications where high accuracy pressure measurement is required The Product features user configurable functions that include Sampling rate Tare Damping Auto off Min Max When the Product is co...

Страница 8: ...perate high pressure systems if you know the correct safety procedures High pressure liquids and gases are hazardous and the energy from them can be released without warning To prevent possible electr...

Страница 9: ...pecified Maximum torque specified is 20 Nm 15 ft lb Special Conditions for Safe Use Misuse If the Product is exposed to overpressure or sudden physical shock such as being dropped examine it for damag...

Страница 10: ...Australian standards This product complies with the WEEE Directive 2002 96 EC marking requirements The affixed label indicates that you must not discard this electrical electronic product in domestic...

Страница 11: ...s the display In Configure Mode push the button to move forward through the menus MIN MAX records minimum and maximum pressure values and saves them to memory Push to show maximum MAX indication Push...

Страница 12: ...re value the pressure shown is not the actual pressure applied How to Setup the Product Before you use the product it is necessary to configure it for your application Push to go to the Setup menu Eac...

Страница 13: ...e on and off Damping smooths readings from pulsating pressure sources Set Sample Rate This function finds how many times pressure is sampled and the display is updated Selections are 0 5 1 3 and 10 sa...

Страница 14: ...ry Hold or down to move faster through the selections by a factor of 10 When you stop the counter push and again to move forward or backward by a factor of 1 The password is factory set and cannot be...

Страница 15: ...with the backlight off When the battery voltage is low the low battery icon shows on the top left of the display To replace the batteries see the How to Change the Batteries section Maintenance How to...

Страница 16: ...s see Figure 2 1 Pull off the Product cover 2 Use a Phillips screwdriver to loosen the captive screw on the battery door 3 Remove the battery door 4 Replace the three AA batteries 5 Install the batter...

Страница 17: ...he back of the Product You can use serial communication to configure and calibrate the Product and move measurement data from the Product to a PC For specifications on the interface see the Specificat...

Страница 18: ...2700G Series Users Manual 12 gsn003 eps Figure 3 USB Power Module and Universal Connectors 1 888 610 7664 sales GlobalTestSupply com Fluke Direct com...

Страница 19: ...of commands to communicate with the Gauge CLS Clears the error queue FAULT Returns an error code from the error queue IDN Identification query Returns the manufacturer model number and firmware revis...

Страница 20: ...its The subsequent list of units is used with the Product psi Pressure in pounds per square inch bar Pressure in bars mBar Pressure in millibars kg cm2 Pressure in kilograms per centimeter squared inH...

Страница 21: ...uge uses the subsequent error codes 101 A non numeric entry was received where it should be a numeric entry 102 Too many significant digits entered 103 Invalid units or parameter value received 105 En...

Страница 22: ...kPa Conversion Factor to kPa psi 0 14503773773 6 894759 bar 0 01 100 MPa 0 001 1000 kgf cm2 0 010197162130 98 06652 inH2O 4 C 4 014742 0 249082 inH2O 20 C 4 021845 0 248642 inH2O 60 F 4 0185886 0 248...

Страница 23: ...o kPa cmH2O 4 C 10 19744 0 09806383 cmH2O 20 C 10 21549 0 09789056 mH2O 4 C 0 1019744 9 806383 mH2O 20 C 0 1021549 9 789056 kPa 1 1 mbar 10 0 1 inHg 0 C 0 2952998 3 386387 mmHg 0 C 7 500618 0 133322 T...

Страница 24: ...on corrosive gas 100 300 500 1000 psi any liquids or gases compatible with 316 stainless steel Above 1000 psi any non flammable non toxic non explosive non oxidizing liquid or gas compatible with 316...

Страница 25: ...n depth 1 5 in Without Protective Cover Pressure Connection in NPT Male Housing Cast ZNAL Display 5 1 2 Digits 16 53 mm 0 65 in high 20 Segment bar graph 0 to 100 Power Battery three size AA alkaline...

Страница 26: ...0 10000 Pressure Range MPa 0 1 0 2 0 7 2 3 5 7 20 35 70 Vacuum Range psi 15 15 12 12 12 12 0 0 0 Vacuum Range kPa 100 100 80 80 80 80 0 0 0 Burst Pressure psi 45 90 1000 2000 2000 10000 10000 10000 15...

Отзывы: