HF070AEN_v0403_03 Atex_IECEx_CSA_FM
Page 26
Label information analog input type - F0..A-XI (inside and outside the enclosure)
Made in Veghel, The Netherlands by Fluidwell bv
IP67
Tamb
-40°C ... +70°C
-40°F ... +158°F
MODEL: F0xx-A-XI
Signal input: (0)4 - 20mA
Intrinsically Safe - Possible static hazard - Do not rub
KEMA 05ATEX1168 X
IECEx KEM 08.0006X
II 1 G Ex ia IIC T4
II 1 D Ex iaD 20 IP 65 / 67 T 100°C
Ga Ex ia IIC T4
Ex iaD 20 IP 65 / 67 T 100°C
Intrinsically Safe for Class I/II/III, Div. 1, Grps A,B,C,D,E,F,G,
Temp. class T4 – Class I, Zone 0, AEx ia IIC T4 - For installation
and entity evaluation refer to control drawing no. FWCD-0001.
CSA Certificate nr: CSA.08.2059461 – FM Project ID: 3033306
Made in Veghel, The Netherlands by Fluidwell bv
MODEL: F0xx-A-XI
Signal input: (0)4 - 20mA
Intrinsically Safe - Possible static hazard - Do not rub
KEMA 05ATEX1168 X
Tamb
IP67
II 1 G Ex ia IIC T4
II 1 D Ex iaD 20 IP 65 / 67 T 100°C
IECEx KEM 08.0006X
Ga Ex ia IIC T4
Ex iaD 20 IP 65 / 67 T 100°C
Battery powered applications:
Replace with certified
FW-LiBAT-00x battery only!
Remark: consult the manual.
Intrinsically Safe for Class I/II/III, Div. 1, Grps A,B,C,D,E,F,G,
Temp. class T4 – Class I, Zone 0, AEx ia IIC T4 - For installation
and entity evaluation refer to control drawing no. FWCD-0001.
CSA Certificate nr: CSA.08.2059461 – FM Project ID: 3033306
-40°C ... +70°C
-40°F ... +158°F
Fig. 12: Label information Intrinsically Safe application.
Label information analog input - loop powered - type A-PL (inside and outside the enclosure)
Made in Veghel, The Netherlands by Fluidwell bv
IP67
Tamb
-40°C ... +70°C
-40°F ... +158°F
MODEL: F0xx-A-PL-XI
Signal input: 4 - 20mA - loop powered
Intrinsically Safe - Possible static hazard - Do not rub
KEMA 05ATEX1168 X
IECEx KEM 08.0006X
II 1 G Ex ia IIC T4
II 1 D Ex iaD 20 IP 65 / 67 T 100°C
Ga Ex ia IIC T4
Ex iaD 20 IP 65 / 67 T 100°C
Intrinsically Safe for Class I/II/III, Div. 1, Grps A,B,C,D,E,F,G,
Temp. class T4 – Class I, Zone 0, AEx ia IIC T4 - For installation
and entity evaluation refer to control drawing no. FWCD-0002.
CSA Certificate nr: CSA.08.2059461 – FM Project ID: 3033306
Made in Veghel, The Netherlands by Fluidwell bv
MODEL: F0xx-A-PL-XI
Signal input: 4 - 20mA - loop powered
Intrinsically Safe - Possible static hazard - Do not rub
KEMA 05ATEX1168 X
Tamb
IP67
II 1 G Ex ia IIC T4
II 1 D Ex iaD 20 IP 65 / 67 T 100°C
IECEx KEM 08.0006X
Ga Ex ia IIC T4
Ex iaD 20 IP 65 / 67 T 100°C
Battery powered applications:
Replace with certified
FW-LiBAT-00x battery only!
Remark: consult the manual.
Intrinsically Safe for Class I/II/III, Div. 1, Grps A,B,C,D,E,F,G,
Temp. class T4 – Class I, Zone 0, AEx ia IIC T4 - For installation
and entity evaluation refer to control drawing no. FWCD-0002.
CSA Certificate nr: CSA.08.2059461 – FM Project ID: 3033306
-40°C ... +70°C
-40°F ... +158°F
Fig. 13: Label information Intrinsically Safe application.