Figure 17. RACER dialog
• The unit’s
Local IP
address will be set to
169.254.a.b
, where
a
and
b
are the last two parts of the unit's unique unit identification (ID)
number. For example, if the unit ID number is
5.12.34.56
, the unit's
IP address will be set as
169.254.34.56
.
• The unit can also be reached using the DHCP fallback IP address
(
192.168.0.10/24
).
• The unit’s Status and link/boot LEDs will blink continuously from left
to right (
green-green-orange-red
), then from right to left (
red-
orange-green-green
). The LEDs will repeat this cycle until the unit
either enters a Fallback condition, or enters
Online
or
Offline
mode.
• The unit will attempt to connect to the internet using DHCP.
NOTE
DHCP is disabled when the unit leaves
Provisioning Mode
.
Make sure that the Fluidmesh 4200 FIBER is connected to a local network
that supports DHCP. If the unit connects successfully to the internet
and
to
the Partners Portal, the
RACER™ Cloud connection info
Status will be
shown as
Connected
(
Fluidmesh 4200 FIBER