Fluidmaster S2DBL Скачать руководство пользователя страница 13

CONE

LOCK NUT

WASHER

WATER

SHUTOFF

FLAT

WASHER

COUPLING

NUT

LOCK NUT

COUPLING

NUT

LOCK NUT

COUPLING

NUT

COUPLING

NUT

WATER

SHUTOFF

SPIRAL

CONE

WASHER

WATER

SHUTOFF

WATER

SHUTOFF

BALL TUBING

METAL/COPPER

FLARED TUBING

METAL FLANGED

TUBING

METAL SPIRAL

TUBING

VINYL/BRAIDED

CONNECTOR

PLASTIC OR METAL

COMPRESSION

 

Use chart to determine the appropriate assembly parts required to properly reconnect the water supply.  

DO NOT 

use plumber’s putty to seal these fittings (Teflon tape optional).  Do not use thread lubricants.  Use of thread sealants or 

lubricants can damage plastic nut and result in flooding and property damage.

Use Fluidmaster coupling nut 
and cone washer to replace 
existing parts.   Water supply 
tube must extend 1/2 inch 
inside threaded shank of valve.

Use existing coupling 
nut and existing flat 
washer.

Use existing spiral 
cone washer.

Captive cone washer 
already included.   
No additional 
washers required.

Do not use Fluidmaster's 
coupling nut and the 
cone washer on plastic or 
metal tubing as shown.

CAUTION:  DO NOT

 use CONE WASHER with PLASTIC SUPPLY LINE or METAL SPIRAL TUBING.

CAUTION

:  Locknut and coupling nut should be hand tightened only!  Over tightening locknut or coupling nut could result in 

breakage and flooding.

Go to our website at www.fluidmaster.com for more information.

13

(Optional for Step 3.1) Identify union type

Completed installation

Содержание S2DBL

Страница 1: ...ply line Refill mount Corrugated tube Roller clamp Refill tube locking clamp PARTS LIST A B C D E F G H I J K L M Flush valve Lever mounting base Flush handle assembly Grey Blue float stop Grey float...

Страница 2: ...nside 1 Press and hold lever to drain water Remove excess water with sponge 2 Disconnect supply line 3 Place bucket under neath fill valve shank Use Channel Locks to loosen and remove lock nut from fi...

Страница 3: ...is reverse threaded 3 Remove old gasket NOTE SAVE the existing parts until installation is complete Measure and record distance of old flush valve from bottom of tank to top of the overflow tube Use s...

Страница 4: ...O 2 5 F Remove flush valve lock nut O from base of Dual Flush Valve assembly Make sure flush valve washer F stays in place www fluidmaster com 4 Step 2 Install Flush Valve 2 1 Prepare flush valve...

Страница 5: ...asurement taken in step 1 3 NOTE DO NOT cut below segment 2 2 Insert refill mount W ensuring it is low enough to fit inside the tank and clears the lid but high enough to allow a minimum of 2 clearanc...

Страница 6: ...ank washer Lock nut and shank washer are required for fill valve installation cone washer and coupling nut for water supply connection The angle adapter will not be needed for this installation NOTE T...

Страница 7: ...ve in tank Check height of the fill valve It must be approximately 3 higher than the overflow tube Adjust by twisting the threaded shank in or out NOTE DO NOT move the locking ring to adjust shank 1 P...

Страница 8: ...hose clamp is secure Slide rubber gasket P onto threaded end of flush valve Use old gasket if supplied new gasket does not fit Secure tank to bowl with bolts G rubber washers H brass washers I and he...

Страница 9: ...chart on pg 13 to determine the appropriate assembly parts required to properly reconnect the water supply NOTE Hand tighten only DO NOT use thread lubricants Use of thread sealants or lubricants can...

Страница 10: ...ustment screw found at the end of float control arm Turn screw clockwise to increase water level and counter clockwise to decrease water level As marked in step 1 1 The blue float controls the half fl...

Страница 11: ...float and repeat If residual water is higher than line marked in step 1 1 lower grey float and repeat You may be able to save water by moving grey float upwards Test flush put toilet paper in bowl and...

Страница 12: ...bowl then increase the water entering the bowl See step 6 5 Push down on the roller Y and roll it to the next lower number Repeat step 4 6 Push down on the roller Y and roll it to the next higher numb...

Страница 13: ...result in flooding and property damage Use Fluidmaster coupling nut and cone washer to replace existing parts Water supply tube must extend 1 2 inch inside threaded shank of valve Use existing coupli...

Страница 14: ...rey float to allow more water to be flushed HALF FLUSH WILL NOT ADEQUATELY REMOVE WASTE Lower blue float to allow more water to be flushed SEAL LEAKING Should dual flush valve leak unclip valve from b...

Страница 15: ...r Inc will provide subject to the Exclusions section set forth below all replacement parts free of charge necessary to correct such defects This LimitedWarranty is null and void if this plumbing produ...

Страница 16: ...flathead screwdriver saw scissors channel locks tape measure crescent wrench wax pencil open P N 5 2473 GRev 4 9 10 www fluidmaster com Tools Required...

Отзывы: