6
7
STEP 5:
INSTALL NEW FILL VALVE
STEP 4:
ADJUST HEIGHT OF NEW FILL VALVE
A:
TWIST FILL VALVE TO ADJUST HEIGHT
Top of fill valve cap should measure roughly 3"
above top of overflow pipe when installed.
TWIST
LEFT
NOTE:
Increasing height allows
more water to fill in the tank.
HOLD
Do Not Move Lock Ring
TOP OF FILL VALVE CAP
TOP OF OVERFLOW PIPE
Fill Valve Cap
3"
A: INSERT FILL VALVE
Position refill tube to face flush
valve making sure fill valve parts
do not interfere with lever arm.
HINT: See next page for full tank setup.
C: PUSH REFILL TUBE
ONTO REFILL PORT
D: CONNECTING REFILL TUBE
TO FLUSH VALVE
FOR KOHLER
®
AQUAPISTON:
Push refill tube onto yellow nipple on flush valve.
B: INSTALL LOCKNUT
Using
Green Toilet Tool
™
, screw
locknut onto fill valve shank (below
tank). Tighten 1/4” beyond hand-
tight.
Do Not Overtighten*.
Green Toilet Tool
™
Hint: Use the
Green Toilet Tool
™
to measure.