K315 – Frequency Output & MIN Alarm KIT
3
3. Specifications
3.1. Technical Data
Associated Flow Sensor: Hall effect (F3.01.H.XX Compact version)
Supply voltage: 12 to 24 VDC regulated
Output signal: square wave
Output frequency: 45Hz per m/s nominal (13.7 Hz per ft/s nominal)
Output type: transistor NPN open collector
Output current: 10 mA max.
Relay Output: mechanical SPDT contact, 3 A @ 30 VDC, 3 A @ 250VAC resistive load
Flow trip point: 0.15 to 1 m/s (0.5 to 3 ft/s) freely adjustable
Local Status Indicator: GREEN Led = Flow RED Led = No Flow
Enclosure: IP65
Operating temperature: 0 to 60°C (32 to 140°F)
Relative humidity: 0 to 95% non-condensing
Housing material: PVC
Standards & Approvals
Manufactured under ISO 9002
CE
3.2. Dimensions
K315 KIT
F3.15 Sensor with O.C. output & MIN alarm
L0 = 68.3 mm (2.69 in)
L1 = 98.5 mm (3.88 in)