F3.20 Paddlewheel Flow Sensor
4
Specific for F3.20.H
Supply voltage: 5 to 24 VDC regulated
Supply current: < 30 mA @ 24 VDC
Output signal: square wave
Output frequency: 45 Hz per m/s nominal (13.7 Hz per ft/s nominal)
Output type: transistor NPN open collector
Output current: 10 mA max.
Cable length: 8 m (26.4 ft) standard, 300 m (990 ft) maximum
Specific for F3.20.P
Supply voltage: 12 to 24 VDC regulated
Supply current: < 30 mA @ 24 VCC
Output signal: square wave
Output frequency: 45 Hz per m/s nominal (13.7 Hz per ft/s nominal)
Output type : Push – Pull (digital input NPN or PNP)
Output current : I
Out
Max < 20 mA
Cable length: 8 m (26.4 ft) standard, 300 m (990 ft) maximum
4. Installation
4.1. Location
Different pipe configurations and obstacles in the flow line such as valves, elbows, pipe
bends and strainers create variations on the flow profile.
Whenever possible follow the EN ISO 5167-1 installation recommendations to locate
the sensor.
Always maximize distance between flow sensor and pump.