![Flowtron Mosquito PowerTrap MT-125 Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/flowtron/mosquito-powertrap-mt-125/mosquito-powertrap-mt-125_technical-manual_2308621005.webp)
In the unlikely event that the burner temperature reaches 1360 F, (738
0
C), the unit will
automatically shut down and the blue LED lights will flash signaling an overheat condition. Allow
the unit to cool and then restart. If the overheat condition reoccurs, replace the propane valve.
During start-up, if the red LED light flashes, this indicates that the burner temperature will not
increase above 760 degrees. If this should occur, disconnect electrical power and allow the unit
to cool. Then restart by applying electrical power. If the condition reoccurs, replace the burner
chamber.