Flowtron Leaf Eater LE-800B Скачать руководство пользователя страница 7

page 7

ELECTRICAL REQUIREMENTS

MOTOR INFORMATION

Grounding Instructions

This shredder should be grounded while in use to
reduce the risk of electric shock to the operator.
The shredder is equipped with a three-conductor
cord and three-prong grounding plug. The green
or green and yellow conductor in the cord is the
grounding wire. Never connect the green or
green and yellow wire to a live terminal.
The shredder is intended for use on a circuit that
has a grounded outlet box that looks like the
one illustrated in figure 8, sketch A.
An adapter which looks like the adapter illustrat-
ed in figure 8, sketch B is available for connect-
ing three-prong plugs to two-prong receptacles.
The green colored rigid ear, lug, or the like on
the adapter, must be connected to a permanent
ground, such as a properly grounded outlet box,
using a metal screw.
Check with a qualified electrician or serviceman
if the grounding instructions are not completely
understood, or if in doubt as to whether the
shredder is properly grounded.

Extensions Cords

Only use three-wire extension cords that have
three-prong grounding plugs and three-hole
receptacles that accept the shredder’s plug.
When using an extension cord, make sure that it
is in good condition.
Use a 14 ga. or heavier extension cord with a
maximum length of 100 ft. An undersized exten-
sion cord will cause a drop in line voltage result-
ing in loss of power and overheating.
Warning – To reduce the risk of electric shock,
only use extension cords intended for outdoor
use, such as cord types SW-A, SOW-A,
STW-A, STOW-A, SJW-A, SJOW-A, SJTW-A or
SJTOW -A.
To prevent disconnection of the shredder cord
from the extension cord during operation, make
a knot as shown in figure 9. Devices for retain-
ing extension cords are also available at your
local hardware retailer.

I m p o rt a n t: Use a 14 ga. or heavier extension cord with a maximum length of 100 ft.

FIGURE 9

METHOD OF SECURING

EXTENSION CORD

(A)

(B)

EXTENSION

CORD

TIE CORD AS SHOWN

CONNECT PLUG & RECEPTACLE

SHREDDER
CORD

FIGURE 8

GROUNDING METHOD

(A)

GROUNDING  PIN

PLUG

LUG

METAL

SCREW

ADAPTER

(B)

COVER OF

GROUNDED OUTLET BOX

1. On/Off Switch

The On/Off switch is located on the left side of the
Lower Housing. To turn unit on lift switch to “On”
position, see figure 10. To turn unit “Off” push
switch down to “Off” position, see figure 10.

2. Circuit Breaker/Reset Button

The circuit breaker/reset button is located on  the
l o w e r, outside front of the motor housing as shown
in figure 10. The unit is designed to shut down in
the event of an overload. To restart, place on/off
switch in “off” position, push reset button, wait
approximately three minutes and then place switch
in “ON” position.

FIGURE 10

ON/OFF
SWITCH

CIRCUIT BREAK-

ER/

RESET SWITCH

Содержание Leaf Eater LE-800B

Страница 1: ...S MANUAL Model LE 800B Assembly Operation Maintenance Repair Parts WARNING Carefullyread and follow safety rules precautions and operating instructions Failure to do so can result in serious personal injury Always Wear Eye Protection During Operation ...

Страница 2: ...ther liability in connection with its products No responsibility is assumed for any consequential damages that may result from the use of a Flowtron product not for damages due to accident abuse lack of responsible care the affixing of any unauthorized attachments loss of parts or subjecting this unit to any but the specified voltage Some states do not allow the exclusion or limitation of the inci...

Страница 3: ... a container or free stand ing on its own legs included with unit Easily replaceable cutting cords with extras supplied with each unit B Unpacking Instructions Your unit has been carefully packed at the fac tory to prevent damage during shipment and storage Carefully unpack the carton as follows 1 Remove contents from carton 2 Check parts against list shown 3 Examine for damage Carton Contents Key...

Страница 4: ...tion Looks Like 3 Container Mounting Bracket 3 Stud Plate 2 Screw Pan Head 10 32 x 3 8 3 Screw Sht Mtl 10 x 5 8 4 Screw Sht Mtl 10 x 1 2 Blk 8 Hex Nut Self Lock 10 32 4 Washer 10 3 Tinnerman Clips 3 Leg Caps 36 Cutting Lines 1 Assembling Legs or Mounting Brackets To install the three legs or the three mounting brackets align the three stud plates with the six mating holes in the lower housing Fast...

Страница 5: ...nd 10 32 hex nuts Place screw heads on inside with nuts on outside Tinnerman Clip three places FIGURE 5 1 Assemble Upper and Lower Housing Install the three Tinnerman Clips onto the edge of the Lower Housing in areas provided Place both Upper Housing and Lower Housing upside down and align the slot in the edge of the Upper Housing with the tab on the Lower Housing Push the Lower Housing down until...

Страница 6: ...3 If it is necessary for any reason to inspect clean or repair the shredder turn the shredder off and wait until it comes to a complete stop then disconnect the power cord before attempting such inspection or repair 14 Disconnect shredder from the power source when not in use before servicing and when changing cutting lines 15 When feeding material into the shredder be extremely careful that piece...

Страница 7: ...heavier extension cord with a maximum length of 100 ft An undersized exten sion cord will cause a drop in line voltage result ing in loss of power and overheating Warning To reduce the risk of electric shock only use extension cords intended for outdoor use such as cord types SW A SOW A STW A STOW A SJW A SJOW A SJTW A or SJTOW A To prevent disconnection of the shredder cord from the extension cor...

Страница 8: ...e operating and safety instructions have been written for your use Failure to read all instruc tions may result in injury Be sure you have read Rules for Safe Operation before proceeding 1 Moving Your Unit Disconnect the power cord from the extension cord or power source grasp the unit along the ridge on the Upper Housing lift and move to wherever you choose Wear Safety Glasses when operating this...

Страница 9: ...authorized Flowtron Service Station 2 Removal Replacement of Cutting Line Your unit is supplied with six strips of six 6 cut ting lines each for a total of 36 cutting lines To separate individual lines simply pinch the indent between lines nearest strip end and peel away Replace cutting cord when a noticeable decrease in shredding efficiency is observed To remove used cutting lines pull used line ...

Страница 10: ...page 10 FLOWTRON EXPLOED VIEW OF LE 8800B WHITE 21 24 19 20 4 23 22 18 17 16 15 14 12 39 36 38 26 27 40 28 29 3 30 12 12 13 31 37 32 4 41 34 35 10 11 9 8 7 6 35 5 1 2 20 18 28 BLACK WHITE GREEN 25 33 33 ...

Страница 11: ...96 494 LEG CAP 3 17 355 3105 SPACER CIRCUIT BREAKER NOT SHOWN 1 18 394 3500 CIRCUIT BREAKER 1 19 367 1429 P01 MOTOR PLATE SEAL 1 20 312 1674 POWER CORD 1 21 355 2062 MOTOR DUCT 1 22 343 2129 NO LONGER USED 1 23 379 3449 MOTOR 1 24 305 3395 MOUNTING PLATE ASSEMBLY MOTOR 1 25 566 399 POP RIVET 1 8 2 26 355 3096 MULCHING DISC 1 27 305 1779 SPINNER HEAD ASSEMBLY 1 28 394 3014 SWITCH ON OFF 1 29 355 13...

Страница 12: ...page 12 357 3389 REV 2 Flowtron Outdoor Products 15 Highland Ave Malden MA 02148 an ARMATRON company 781 321 2300 www flowtron com ...

Отзывы: