Flowserve Valdisk 150 Скачать руководство пользователя страница 3

37-3

Body

          Packing Retainer  

(Item No. 85)

       Packing  

(Item No. 88)

    Shaft  

(Item No. 51)

Packing Box Nut  

(Item No. 117)

Gland Flange  

(Item No. 80)

Packing Box Stud

(Item No. 109)

   Packing Follower  
    

 (Item No. 87)

          Shaft Bearing  
               

(Item No. 83)

                     Thrust Washer  
                               

(Item No. 82)

Disc  

(Item No. 50)

Disc Stop

Thrust 
Washer  

(Item No. 82)

Shaft
Bearing

(Item No. 84)

Taper Pin

(Item No. 1)

(Item No. 52)

Figure 1: Body Assembly

NOTE: Item numbers correspond directly to the valve’s bill of material.  Refer to it for specific part numbers.

3. Clean valve and re-paint areas of severe oxidation.

4. Check packing box bolting for proper tightness.

Packing nuts should be slightly over finger-tight;
however, tighten as necessary to prevent stem
leakage.

CAUTION: Do not overtighten packing.

5. If the valve is supplied with a lubricator, check lubri-

cant supply and add lubricant if necessary.

6. If possible, stroke the valve and check for smooth,

full-stroke operation by observing the disc position
indicator plate mounted on the transfer case.  Un-
steady movement of the disc could indicate an inter-
nal valve problem (jerky motion is normal whenever
Grafoil packing is used).

7. Check positioner calibration by observing the

gauges and disc position indicator plate.  Make sure
positioner is calibrated to the correct range.  Refer
to positioner instructions for additional preventative
maintenance.

8. If possible, depressurize the actuator, and remove

the actuator transfer case cover plate, and make
sure the positioner linkage is securely fastened.

CAUTION:  Never apply air to the actuator with-
out the cover plate installed; otherwise, the un-
supported shaft may sustain damage.

9. Be certain all accessories, brackets and bolting are

securely fastened.

10. If possible, remove the air supply and observe the

position indicator plate for correct fail-safe action.

11. Spray soap solution around the cylinder retaining

ring and the adjusting screw to check for air leaks
through the O-rings.

12. Clean any dirt or other foreign material from the

exposed portion of the shaft.

13. If an air filter is supplied, check and replace the

cartridge if necessary.

Содержание Valdisk 150

Страница 1: ...e legs and outer end of the body 3 In the event of shipping damage contact your ship per immediately 4 Should any problem arise contact your Valtek rep resentative GENERAL INFORMATION The following in...

Страница 2: ...Before installing the valve clean the line of dirt scale welding chips and other foreign material Clean gasket surfaces thoroughly to insure leak proof joints 2 Check flow direction to be sure valve i...

Страница 3: ...icator plate mounted on the transfer case Un steadymovementofthedisccouldindicateaninter nal valve problem jerky motion is normal whenever Grafoil packing is used 7 Check positioner calibration by obs...

Страница 4: ...m the body sub assembly 2 Depressurize actuator and allow it to move to its fail position 3 Remove the bolts connecting the yoke to the actua tor subassembly 4 Slide the entire actuator assembly off t...

Страница 5: ...r pin slot on top Do not dislodge the thrust bearing 7 Insert the second thrust bearing between the disc and the valve body Align both bearings with the disc 8 Insert the shaft into the body with the...

Страница 6: ...of the disc marks provided on the end of the valve shaft and on the actuator lever arm should be aligned 2 Bolt the actuator yoke to the valve body Be certain the stroke indicator plate is positioned...

Страница 7: ...ing surface 3 Replace disc 4 Improper handwheel adjustment acting 4 Adjust handwheel until disc seats properly as limitstop Leakage through line 1 Dirty line gasket surfaces 1 Clean gasket surfaces an...

Страница 8: ...ory results by reliance thereon Nothing contained herein is to be construed as a warranty or guarantee express or implied regarding any matter with respect to this product Because Flowserve is continu...

Отзывы: