Safety Notices

 

  MISUSE AND ABUSE OF THIS METER CAN CAUSE SERIOUS INJURIES. 

  READ ALL CAUTIONS AND INSTRUCTIONS BEFORE USING METER. 

  INSPECT BEFORE USING AND REPLACE ANY DEFECTIVE COMPONENTS. 

  EXPOSURE TO CHEMICALS CAN CAUSE SERIOUS INJURIES.  ALWAYS WEAR 

PROPER PROTECTIVE CLOTHING AND DEVICES WHEN METERING CHEMICALS. 

  REFER TO AND FOLLOW CHEMICAL MANUFACTURER’S HANDLING 

INSTRUCTIONS. 

 

 

 

Description 

Scienco Products Model SEM-10 and SEM-10FT flow meters are identical in operation and 
performance.  The SEM-10 is intended for fixed mounting to a pump or other device that can 
provide support.  The SEM-10FT is designed for mounting at hose end.  The female threaded 
connection on the SEM-10FT should be connected to the hose and a ball valve should be 
connected to the male threaded connection. 

 

 

Theory of Operation 

The SEM-10/SEM-10FT flow meter is a positive displacement, nutating disk, fluid metering unit.  
As fluid flows through the unit, it causes the nutating disk to move which in turn causes the 
rotation of a hermetically sealed magnet disk.  The meter electronic assembly counts the 
number of revolutions of the magnet and mathematically determines, based on the calibration 
number, the quantity of liquid that has passed through the meter.  The self-contained electronic 
assembly features a large Liquid Crystal Display (LCD), and simple four-button operation. 

 

 

Features 

  Simple, one touch operation 

  Large, 0.7-inch LCD Display Characters 

  Choice of three calibration modes 

  Large positive touch buttons 

Содержание Scienco SEM-10

Страница 1: ...1 Operator Manual SEM 10 and SEM 10FT Electronic Flow Meter...

Страница 2: ...e threaded connection on the SEM 10FT should be connected to the hose and a ball valve should be connected to the male threaded connection Theory of Operation The SEM 10 SEM 10FT flow meter is a posit...

Страница 3: ...Up With Flow Material of Construction Fluid Housing Form Cover Nylon or Polypropylene Meter Chamber Polypropylene Sulfide PPS Stainless Steel O rings Viton or EPDM Electronic Housing Nylon Screws Sta...

Страница 4: ...4 Figure 1 SEM 10 Figure 2 SEM 10FT...

Страница 5: ...Resets Current Total to zero Also used to enter CAL 3 mode and to increase the CAL 3 number during the calibration When depressed and held with Current Total displayed it shows Total 2 Also used to e...

Страница 6: ...cedures Model SEM 10 SEM 10FT Flow Meter has three calibration options CAL 1 CAL 2 and CAL 3 This flow meter can be calibrated in any unit desired i e gallons liters pounds acres pints etc CAL 1 requi...

Страница 7: ...return to the Current Total screen and should read previous total Note ERR will be displayed if too few or too many counts have been received during the calibration You must record a volume between 0...

Страница 8: ...a 1 inch ball valve on the meter outlet male threads Use thread sealant tape or pipe dope to seal threaded connections CAUTION DO NOT OVERTIGHTEN THREADED CONNECTIONS BREAKAGE CAN OCCUR RESULTING IN E...

Страница 9: ...LOVES AND PROPER EYE PROTECTION WHILE WORKING WITH CHEMICALS CAUTION ENSURE THAT THE METER IS NOT UNDER PRESSURE BEFORE CONTINUING Remove the eight 8 PH 13 screws to remove electronic assembly S10 11...

Страница 10: ...e CAL 1 or CAL 2 while fluid is being pumped through meter if it does not BLINK then the electronics is not sensing rotation Disassemble meter and clean out or replace the meter chamber SEM 10 KIT Vol...

Страница 11: ...00 343 PUMP 7867 Polypropylene Nylon SEM 10 SEM 10FT Parts List Qty Part No Description 8 PH 13 SS Screw Long 1 S10 11 COMPLETE Electronics Assembly 1 S10 12 Meter Gasket 4 PH 03 SS Screw Short 1 S10...

Страница 12: ...12 Figure 3 SEM 10 and SEM 10FT Parts Diagram Note S10 05N is 90 Nylon Housing S10 10 is Nylon flow through Housing S10 10P is Polypropylene flow through Housing...

Страница 13: ...B point of shipment provided the Purchaser has stored installed maintained and operated the Equipment in accordance with good industry practices The Company shall not be liable for any repairs replac...

Отзывы: