4.13 Compress the drive collar to be  

 

even with the end of the sleeve  

 

assembly. This will also compress  

 

the gland. While holding the    

 

collar in compression, tighten    

 

the quarter dog set screws into   

 

the holes in the sleeve until    

 

snug. (

Figure 13

)

 

Be careful    

 

not to distort the sleeve by    

 

over tightening the quarter    

 

dog set screws.

  

 

Note: if the drive collar cannot be    

 

compressed to be even with    

 

the end of the sleeve, the gland  

 

drive pins may not be aligned.    

 

If this is the case, do not  

 

 

attempt to rotate the gland to   

 

align the pins. 

The gland should  

 

be disassembled and re-aligned  

 

prior to proceeding further. 

4.14 Install the sleeve gasket O-ring 

19

   

 

into the inside diameter groove of  

 

the sleeve assembly. (

Figure 14

)

4.15 Apply an even coat of 3M

®2

    

 

Super 77 spray adhesive,  

 

 

free of bubbles and nodules,    

 

to the gland gasket  

18 

. Adhere  

 

the gasket to the gland gasket   

 

surface. (

Figure 14

)

5  Static Testing

Figure 13

Figure 14

Sleeve 

Gasket 

O-ring 

19

Gland 

Gasket  

18

5.1  Flowserve manufacturing typically air tests the ISC at 25 psig. A pressure  

 

drop of less than one pound at 25 psig is acceptable. To static test the seal,    

 

bolt it to a single seal test barrel or to the equipment. Secure the cup point  

 

set screws to the stub shaft or equipment shaft to prevent deformation  

 

of the setting devices due to axial loads. The seal may be pressurized  

 

 

through either of the tangential flush ports. If the seal does not pass the  

 

 

static pressure test, disassemble the seal and inspect for O-ring damage, as  

 

this is the most common cause of static test failure.

6 Installation

6.1  Refer to the ISC Installation Instructions, FIS120, for proper seal installation.

Содержание ISC1PX

Страница 1: ...Repair Instructions Experience In Motion ISC ISC1PX Single Pusher Seal...

Страница 2: ...ket 11 Gland Assembly 24 Gland Bushing 103 Setting Device 40 Cap Screw 1 Sleeve Assembly 2 Seal Drive 183 Vibration Dampener 58 Drive Collar 57 Cup Point Set Screw 57 1 Quarter Dog Set Screw 19 Sleeve...

Страница 3: ...gure 2 B Seal Drive 2 Inspect for wear or corrosion especially at drive flat surfaces on ID of drive ring C Drive end roundness No greater than 0 001 TIR 3 1 There are certain critical areas of each p...

Страница 4: ...s by dia metrical size There are two sizes three of the largest size O rings 13 13 1 and 76 and one of the smallest size O ring 19 Prior to installing each O ring at its respective step lightly lubric...

Страница 5: ...tionary face and press the stationary face support in place using finger pressure only Figure 8 4 8 Install the springs 16 in holes of stator face support 4 9 Place the stationary face and stationary...

Страница 6: ...at the pins remain engaged 4 12 Place the drive collar 58 onto the end of the sleeve with the Flowserve logo facing up Figure 12 Align the quarter dog set screws with the smaller holes in the end of t...

Страница 7: ...ply an even coat of 3M 2 Super 77 spray adhesive free of bubbles and nodules to the gland gasket 18 Adhere the gasket to the gland gasket surface Figure 14 5 Static Testing Figure 13 Figure 14 Sleeve...

Страница 8: ...n its employees and contractors in the safe use of Flowserve products in connection with the specific application While the information and specifications contained in this literature are believed to...

Отзывы: